Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW165(23)P1310x990 is a 165.0 W STC (146.6 W PTC) Multi-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 10.19% efficiency, 29.0 V Voc at 25 C, and 32.65 V cold Voc at -10 C (18 panels max per 600 V string).

STC Wattage
165.0 W
PTC Wattage
146.6 W
Voc @ 25C
29.0 V
Efficiency
10.19%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW165(23)P1310x990 Compare Against Peer CEC Listings?

Solar engineering breakdown for Lightway Green New Energy LW165(23)P1310x990: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Lightway Green New Energy and peers, Lightway Green New Energy LW165(23)P1310x990 stands 113.8 W below the 278.8 W Multi-c-Si median and typical 88.8% PTC-to-STC thermal output (146.6 W real-world rating). Sizing 6 kW (37 panels) to 10 kW (61 panels) yields $1,529-$2,518/yr in baseline US bill offset. Lower 29.0 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters.

Where Does Lightway Green New Energy LW165(23)P1310x990 Fall Across Listed CEC Models?

Distribution marker showing Lightway Green New Energy LW165(23)P1310x990 (165.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW165(23)P1310x990 (165.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 165.0 W

What Dataset Percentiles Define Lightway Green New Energy LW165(23)P1310x990?

Dataset percentiles tracking Lightway Green New Energy LW165(23)P1310x990 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Lightway Green New Energy LW165(23)P1310x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW165(23)P1310x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage165.0 WPTC/STC Retention88.8%Module Efficiency10.19%

What Do the Dataset Ranks Show for Lightway Green New Energy LW165(23)P1310x990?

Benchmark highlights for Lightway Green New Energy LW165(23)P1310x990 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,351 / 21,677

165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,620

10.19% Aperture Efficiency

Power density 101.9 W/m2 (9.72 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

18 Panels Max @ -10 C (600 V)

Cold Voc reaches 32.65 V at -10 C (587.7 V string) and 33.7 V at -20 C (17 max).

8 kW Reference Array

49 Panels = 8,085 W STC

Occupies 79.3 m2 (854 sq ft) producing 7,183 W PTC; NEC 690.8 OCPD floor is 12.32 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.0 * (1 + (-0.36/100) * (-10 - 25)) = 32.65 V | OCPD = 1.56 * 7.9 = 12.32 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW165(23)P1310x990: Voc=29.0 V, beta_Voc=-0.36%/C, Isc=7.9 A, STC=165.0 W, Area=1.619 m2.

Result: 18 panels max on 600 V (587.7 V); 49 panels for 8 kW (854 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW165(23)P1310x990?

Official CEC datasheet figures for Lightway Green New Energy LW165(23)P1310x990 (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW165(23)P1310x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 165.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 146.6 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 29.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 23.0 V / 7.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 10.19% (1.619 m2) Array roof footprint density
Cell Count & Technology 48 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW165(23)P1310x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Lightway Green New Energy LW165(23)P1310x990 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 37 6.11 kW 645 sq ft $1,529 $2,586
8 kW Class 49 8.09 kW 854 sq ft $2,025 $3,424
10 kW Class 61 10.06 kW 1,063 sq ft $2,518 $4,258

How Many Lightway Green New Energy LW165(23)P1310x990 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Lightway Green New Energy LW165(23)P1310x990 (32.65 V at 14 F).

Computed from Voc=29.0V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 33.7 V 17 panels 572.9 V 29 panels
-10 C (14 F) 32.65 V 18 panels 587.7 V 30 panels
0 C (32 F) 31.61 V 18 panels 569.0 V 31 panels
25 C (77 F STC) 29.0 V 20 panels 580.0 V 34 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW165(23)P1310x990?

Competing CEC solar panels closest to Lightway Green New Energy LW165(23)P1310x990 in nameplate wattage and Voc, starting with Guangdong Golden Glass Technologies GG165M2-24/1324x992.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Guangdong Golden Glass Technologies GG165M2-24/1324x992
Guangdong Golden Glass Technologies
165.0 W Tie (0 W) 28.8 V 12.56% 89.7%
Yingli Energy (China) YL170P-23b
Yingli Energy (China)
170.0 W +5.0 W 29.0 V 13.24% 90.7%
Mitsubishi Electric PV-MF170UD4
Mitsubishi Electric
170.0 W +5.0 W 29.9 V 12.28% 89.2%
Mitsubishi Electric PV-UD170MF5
Mitsubishi Electric
170.0 W +5.0 W 29.9 V 12.29% 88.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW165(23)P1310x990?

Evaluate Lightway Green New Energy LW165(23)P1310x990 (165.0 W STC, 29.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW165(23)P1310x990 reaches 33.7 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 49 panels for an 8 kW build require 854 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (854 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW165(23)P1310x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW165(23)P1310x990 8 kW Residential Fit

Needs 49 modules (854 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Guangdong Golden Glass Technologies GG165M2-24/1324x992.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 146.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW165(23)P1310x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Lightway Green New Energy LW165(23)P1310x990?

Multiplying Lightway Green New Energy LW165(23)P1310x990's 7.9 A short-circuit current by 1.56 equals 12.32 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Lightway Green New Energy LW165(23)P1310x990 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 32.65 V cold Voc at 14 F and handles 7.9 A Isc; string inverters cap Lightway Green New Energy LW165(23)P1310x990 at 18 panels on 600 V.

Is Lightway Green New Energy LW165(23)P1310x990 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lightway Green New Energy LW165(23)P1310x990 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.