Skip to main content
WireAndSun
Calculators
CEC PV Module

Lightway Green New Energy LW315(35)P1970x990 — CEC Solar Module Specifications

Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW315(35)P1970x990 is a 315.0 W STC (282.4 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.15% efficiency, 45.79 V Voc at 25 C, and 51.72 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
282.4 W
Voc @ 25C
45.79 V
Efficiency
16.15%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW315(35)P1970x990 Compare Against Peer CEC Listings?

Solar engineering breakdown for Lightway Green New Energy LW315(35)P1970x990: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 315.0 W STC and 282.4 W PTC, Lightway Green New Energy LW315(35)P1970x990 sits -70.0 W vs all-CEC median (below all-CEC median; higher than 27.3% of peers) among 21,677 listed modules. Power density reaches 161.5 W/m2 (3.76 percentage points below 19.91% CEC median). Mid-range 45.79 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Centrosolar America EP72 315BW rates 315.0 W.

Where Does Lightway Green New Energy LW315(35)P1970x990 Fall Across Listed CEC Models?

Distribution marker showing Lightway Green New Energy LW315(35)P1970x990 (315.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW315(35)P1970x990 (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 315.0 W

What Dataset Percentiles Define Lightway Green New Energy LW315(35)P1970x990?

Dataset percentiles tracking Lightway Green New Energy LW315(35)P1970x990 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Lightway Green New Energy LW315(35)P1970x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW315(35)P1970x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention89.7%Module Efficiency16.15%

What Do the Dataset Ranks Show for Lightway Green New Energy LW315(35)P1970x990?

Benchmark highlights for Lightway Green New Energy LW315(35)P1970x990 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,916

16.15% Aperture Efficiency

Power density 161.5 W/m2 (3.76 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.72 V at -10 C (568.9 V string) and 53.41 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,342 W PTC; NEC 690.8 OCPD floor is 13.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.79 * (1 + (-0.37/100) * (-10 - 25)) = 51.72 V | OCPD = 1.56 * 8.92 = 13.92 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW315(35)P1970x990: Voc=45.79 V, beta_Voc=-0.37%/C, Isc=8.92 A, STC=315.0 W, Area=1.95 m2.

Result: 11 panels max on 600 V (568.9 V); 26 panels for 8 kW (546 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW315(35)P1970x990?

Official CEC datasheet figures for Lightway Green New Energy LW315(35)P1970x990 (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW315(35)P1970x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 282.4 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.79 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.81 V / 8.57 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.37 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.15% (1.95 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW315(35)P1970x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Lightway Green New Energy LW315(35)P1970x990 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 420 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 546 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 672 sq ft $2,523 $4,266

How Many Lightway Green New Energy LW315(35)P1970x990 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Lightway Green New Energy LW315(35)P1970x990 (51.72 V at 14 F).

Computed from Voc=45.79V and beta_Voc=-0.37%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.41 V 11 panels 587.5 V 18 panels
-10 C (14 F) 51.72 V 11 panels 568.9 V 19 panels
0 C (32 F) 50.03 V 11 panels 550.3 V 19 panels
25 C (77 F STC) 45.79 V 13 panels 595.3 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW315(35)P1970x990?

Competing CEC solar panels closest to Lightway Green New Energy LW315(35)P1970x990 in nameplate wattage and Voc, starting with Centrosolar America EP72 315BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
Boviet Solar Technology Co Ltd BVM6612M-315
Boviet Solar Technology Co Ltd
315.0 W Tie (0 W) 46.1 V 16.23% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW315(35)P1970x990?

Evaluate Lightway Green New Energy LW315(35)P1970x990 (315.0 W STC, 45.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW315(35)P1970x990 reaches 53.41 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW315(35)P1970x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW315(35)P1970x990 8 kW Residential Fit

Needs 26 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EP72 315BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 282.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW315(35)P1970x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Lightway Green New Energy LW315(35)P1970x990 panels fit on a 600 V winter solar string?

At -10 C (14 F), Lightway Green New Energy LW315(35)P1970x990 cold Voc rises from 45.79 V to 51.72 V (beta_Voc -0.37%/C), capping a 600 V string at 11 panels (568.9 V).

How much roof area does an 8 kW array of Lightway Green New Energy LW315(35)P1970x990 need?

An 8 kW DC system uses 26 Lightway Green New Energy LW315(35)P1970x990 modules (8,190 W STC / 7,342 W PTC), covering roughly 546 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Lightway Green New Energy LW315(35)P1970x990 compare against Centrosolar America EP72 315BW?

Lightway Green New Energy LW315(35)P1970x990 outputs 315.0 W STC (45.79 V Voc, rank #15,387 of 21,677), while Centrosolar America EP72 315BW delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.