Skip to main content
WireAndSun
Calculators
CEC PV Module

Lightway Green New Energy LW305(35)P1970x990 — CEC Solar Module Specifications

Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW305(35)P1970x990 is a 305.0 W STC (273.2 W PTC) Multi-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.64% efficiency, 45.31 V Voc at 25 C, and 51.18 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
273.2 W
Voc @ 25C
45.31 V
Efficiency
15.64%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW305(35)P1970x990 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Lightway Green New Energy LW305(35)P1970x990 (Multi-c-Si) residential solar systems.

Homeowners evaluating Lightway Green New Energy LW305(35)P1970x990 need 20 panels for 6 kW or 27 panels (567 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (567 sq ft). Under NEC 690.7(A), beta_Voc (-0.37%/C) pushes open-circuit voltage to 51.18 V at 14 F and 52.85 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Lightway Green New Energy LW305(35)P1970x990 Fall Across Listed CEC Models?

Comparison of Lightway Green New Energy LW305(35)P1970x990 (305.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW305(35)P1970x990 (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 305.0 W

What Dataset Percentiles Define Lightway Green New Energy LW305(35)P1970x990?

Relative ranking of Lightway Green New Energy LW305(35)P1970x990 across nameplate watts, 89.6% PTC thermal ratio, and module aperture efficiency.

Lightway Green New Energy LW305(35)P1970x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW305(35)P1970x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention89.6%Module Efficiency15.64%

What Do the Dataset Ranks Show for Lightway Green New Energy LW305(35)P1970x990?

Summary of Lightway Green New Energy LW305(35)P1970x990 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,727

15.64% Aperture Efficiency

Power density 156.4 W/m2 (4.27 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.18 V at -10 C (563.0 V string) and 52.85 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 52.6 m2 (567 sq ft) producing 7,376 W PTC; NEC 690.8 OCPD floor is 13.67 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.31 * (1 + (-0.37/100) * (-10 - 25)) = 51.18 V | OCPD = 1.56 * 8.76 = 13.67 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW305(35)P1970x990: Voc=45.31 V, beta_Voc=-0.37%/C, Isc=8.76 A, STC=305.0 W, Area=1.95 m2.

Result: 11 panels max on 600 V (563.0 V); 27 panels for 8 kW (567 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW305(35)P1970x990?

Complete CEC test sheet for Lightway Green New Energy LW305(35)P1970x990 including Isc (8.76 A), Voc (45.31 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW305(35)P1970x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 273.2 W (89.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.31 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.76 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.34 V / 8.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.37 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.64% (1.95 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW305(35)P1970x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Lightway Green New Energy LW305(35)P1970x990.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 420 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 567 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 693 sq ft $2,518 $4,258

How Many Lightway Green New Energy LW305(35)P1970x990 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Lightway Green New Energy LW305(35)P1970x990 (45.31 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.31V and beta_Voc=-0.37%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.85 V 11 panels 581.4 V 18 panels
-10 C (14 F) 51.18 V 11 panels 563.0 V 19 panels
0 C (32 F) 49.5 V 12 panels 594.0 V 20 panels
25 C (77 F STC) 45.31 V 13 panels 589.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW305(35)P1970x990?

Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W Tie (0 W) 45.0 V 15.63% 90.3%
Chinaland Solar Energy HSE310-72M
Chinaland Solar Energy
310.0 W +5.0 W 45.4 V 16.06% 90.3%
GCL System Integration Technology Co Ltd GCL-P6/72310
GCL System Integration Technology Co Ltd
310.0 W +5.0 W 45.4 V 15.98% 90.5%
Advance Power API-P310
Advance Power
310.0 W +5.0 W 45.22 V 15.89% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW305(35)P1970x990?

Evaluate Lightway Green New Energy LW305(35)P1970x990 (305.0 W STC, 45.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW305(35)P1970x990 reaches 52.85 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 567 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (567 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW305(35)P1970x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW305(35)P1970x990 8 kW Residential Fit

Needs 27 modules (567 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 273.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW305(35)P1970x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Lightway Green New Energy LW305(35)P1970x990 PTC wattage (273.2 W) lower than STC (305.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 273.2 W PTC (89.6% retention) across Lightway Green New Energy LW305(35)P1970x990's 1.95 m2 aperture.

Who should skip Lightway Green New Energy LW305(35)P1970x990 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 Lightway Green New Energy LW305(35)P1970x990 panels (567 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P612T305G.

What is the 1,000 V commercial string limit for Lightway Green New Energy LW305(35)P1970x990?

On 1,000 V commercial inverters at -10 C (51.18 V cold Voc), Lightway Green New Energy LW305(35)P1970x990 fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.