Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitsubishi Electric PV-UD170MF5 — CEC Solar Module Specifications

Manufacturer: Mitsubishi Electric Registry: CEC Verified Engineering Specification

Mitsubishi Electric PV-UD170MF5 is a 170.0 W STC (150.9 W PTC) Multi-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 12.29% efficiency, 29.9 V Voc at 25 C, and 33.71 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
170.0 W
PTC Wattage
150.9 W
Voc @ 25C
29.9 V
Efficiency
12.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitsubishi Electric PV-UD170MF5 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mitsubishi Electric PV-UD170MF5 (Multi-c-Si) residential solar systems.

Homeowners evaluating Mitsubishi Electric PV-UD170MF5 need 36 panels for 6 kW or 48 panels (715 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (715 sq ft). Under NEC 690.7(A), beta_Voc (-0.364%/C) pushes open-circuit voltage to 33.71 V at 14 F and 34.8 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Mitsubishi Electric PV-UD170MF5 Fall Across Listed CEC Models?

Comparison of Mitsubishi Electric PV-UD170MF5 (170.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitsubishi Electric PV-UD170MF5 (170.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitsubishi Electri: 170.0 W

What Dataset Percentiles Define Mitsubishi Electric PV-UD170MF5?

Relative ranking of Mitsubishi Electric PV-UD170MF5 across nameplate watts, 88.8% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Mitsubishi Electric PV-UD170MF5 Engineering BenchmarksPercentile comparison of Mitsubishi Electric PV-UD170MF5 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage170.0 WPTC/STC Retention88.8%Module Efficiency12.29%

What Do the Dataset Ranks Show for Mitsubishi Electric PV-UD170MF5?

Summary of Mitsubishi Electric PV-UD170MF5 output rank, 8 kW array size (48 panels), efficiency rating, and 600 V string limit.

Rank #21,323 / 21,677

170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,549

12.29% Aperture Efficiency

Power density 122.9 W/m2 (7.62 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.71 V at -10 C (573.1 V string) and 34.8 V at -20 C (17 max).

8 kW Reference Array

48 Panels = 8,160 W STC

Occupies 66.4 m2 (715 sq ft) producing 7,243 W PTC; NEC 690.8 OCPD floor is 12.21 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.9 * (1 + (-0.364/100) * (-10 - 25)) = 33.71 V | OCPD = 1.56 * 7.83 = 12.21 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-UD170MF5: Voc=29.9 V, beta_Voc=-0.364%/C, Isc=7.83 A, STC=170.0 W, Area=1.383 m2.

Result: 17 panels max on 600 V (573.1 V); 48 panels for 8 kW (715 sq ft).

What Are the Published CEC Specifications for Mitsubishi Electric PV-UD170MF5?

Complete CEC test sheet for Mitsubishi Electric PV-UD170MF5 including Isc (7.83 A), Voc (29.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-UD170MF5.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 170.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 150.9 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 29.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 23.7 V / 7.19 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.29% (1.383 m2) Array roof footprint density
Cell Count & Technology 50 cells (Multi-c-Si) Monofacial backsheet

How Many Mitsubishi Electric PV-UD170MF5 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mitsubishi Electric PV-UD170MF5.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 36 6.12 kW 536 sq ft $1,532 $2,590
8 kW Class 48 8.16 kW 715 sq ft $2,042 $3,454
10 kW Class 59 10.03 kW 878 sq ft $2,510 $4,245

How Many Mitsubishi Electric PV-UD170MF5 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Mitsubishi Electric PV-UD170MF5 (29.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=29.9V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.8 V 17 panels 591.6 V 28 panels
-10 C (14 F) 33.71 V 17 panels 573.1 V 29 panels
0 C (32 F) 32.62 V 18 panels 587.2 V 30 panels
25 C (77 F STC) 29.9 V 20 panels 598.0 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-UD170MF5?

Four comparable CEC modules such as Lightway Green New Energy LW170(23)P1310x990 (170.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Lightway Green New Energy LW170(23)P1310x990
Lightway Green New Energy
170.0 W Tie (0 W) 29.5 V 13.25% 89.4%
Yingli Energy (China) YL170P-23b
Yingli Energy (China)
170.0 W Tie (0 W) 29.0 V 13.24% 90.7%
Lightway Green New Energy LW175(23)P1310x990
Lightway Green New Energy
175.0 W +5.0 W 29.5 V 13.63% 89.4%
Lightway Green New Energy LW165(23)P1310x990
Lightway Green New Energy
165.0 W -5.0 W 29.0 V 10.19% 88.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-UD170MF5?

Evaluate Mitsubishi Electric PV-UD170MF5 (170.0 W STC, 29.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-UD170MF5 reaches 34.8 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 48 panels for an 8 kW build require 715 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (715 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-UD170MF5 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitsubishi Electric PV-UD170MF5 8 kW Residential Fit

Needs 48 modules (715 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Lightway Green New Energy LW170(23)P1310x990.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 150.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-UD170MF5 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Mitsubishi Electric PV-UD170MF5 PTC wattage (150.9 W) lower than STC (170.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 150.9 W PTC (88.8% retention) across Mitsubishi Electric PV-UD170MF5's 1.383 m2 aperture.

Who should skip Mitsubishi Electric PV-UD170MF5 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 48 Mitsubishi Electric PV-UD170MF5 panels (715 sq ft) leave unusable roof gaps vs. Lightway Green New Energy LW170(23)P1310x990.

What is the 1,000 V commercial string limit for Mitsubishi Electric PV-UD170MF5?

On 1,000 V commercial inverters at -10 C (33.71 V cold Voc), Mitsubishi Electric PV-UD170MF5 fits up to 29 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitsubishi Electric PV-UD170MF5.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.