Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitsubishi Electric PV-MLE270HD2 — CEC Solar Module Specifications

Manufacturer: Mitsubishi Electric Registry: CEC Verified Engineering Specification

Mitsubishi Electric PV-MLE270HD2 is a 270.0 W STC (242.8 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 18.49% efficiency, 38.4 V Voc at 25 C, and 42.93 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
242.8 W
Voc @ 25C
38.4 V
Efficiency
18.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitsubishi Electric PV-MLE270HD2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mitsubishi Electric PV-MLE270HD2 (Mono-c-Si) residential solar systems.

Mitsubishi Electric PV-MLE270HD2 delivers 184.9 W/m2 (1.42 percentage points below 19.91% CEC median) and typical 89.9% PTC-to-STC thermal output (242.8 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (471 sq ft). At -4 F (-20 C), string voltage climbs to 44.22 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Bluesun Solar Energy Tech CoLtd BSM270M-60 (270.0 W).

Where Does Mitsubishi Electric PV-MLE270HD2 Fall Across Listed CEC Models?

Comparison of Mitsubishi Electric PV-MLE270HD2 (270.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitsubishi Electric PV-MLE270HD2 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitsubishi Electri: 270.0 W

What Dataset Percentiles Define Mitsubishi Electric PV-MLE270HD2?

Relative ranking of Mitsubishi Electric PV-MLE270HD2 across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Mitsubishi Electric PV-MLE270HD2 Engineering BenchmarksPercentile comparison of Mitsubishi Electric PV-MLE270HD2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention89.9%Module Efficiency18.49%

What Do the Dataset Ranks Show for Mitsubishi Electric PV-MLE270HD2?

Summary of Mitsubishi Electric PV-MLE270HD2 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,369

18.49% Aperture Efficiency

Power density 184.9 W/m2 (1.42 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.93 V at -10 C (558.1 V string) and 44.22 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 43.8 m2 (471 sq ft) producing 7,284 W PTC; NEC 690.8 OCPD floor is 14.32 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.4 * (1 + (-0.337/100) * (-10 - 25)) = 42.93 V | OCPD = 1.56 * 9.18 = 14.32 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-MLE270HD2: Voc=38.4 V, beta_Voc=-0.337%/C, Isc=9.18 A, STC=270.0 W, Area=1.46 m2.

Result: 13 panels max on 600 V (558.1 V); 30 panels for 8 kW (471 sq ft).

What Are the Published CEC Specifications for Mitsubishi Electric PV-MLE270HD2?

Complete CEC test sheet for Mitsubishi Electric PV-MLE270HD2 including Isc (9.18 A), Voc (38.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-MLE270HD2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 242.8 W (89.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.18 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.9 V / 8.48 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.337 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.49% (1.46 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Mitsubishi Electric PV-MLE270HD2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mitsubishi Electric PV-MLE270HD2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 361 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 471 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 597 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Mitsubishi Electric Series?

Related Mitsubishi Electric power steps and black/silver trims consolidated into this Mitsubishi Electric PV-MLE270HD2 series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Mitsubishi Electric PV-MLE270HD2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mitsubishi Electric PV-MLE265HD2 265.0 W 238.1 W 38.2 V 31.7 V 18.15%
Mitsubishi Electric PV-MLE270HD2 270.0 W 242.8 W 38.4 V 31.9 V 18.49%

How Many Mitsubishi Electric PV-MLE270HD2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Mitsubishi Electric PV-MLE270HD2 (38.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.4V and beta_Voc=-0.337%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.22 V 13 panels 574.9 V 22 panels
-10 C (14 F) 42.93 V 13 panels 558.1 V 23 panels
0 C (32 F) 41.64 V 14 panels 583.0 V 24 panels
25 C (77 F STC) 38.4 V 15 panels 576.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-MLE270HD2?

Four comparable CEC modules such as Bluesun Solar Energy Tech CoLtd BSM270M-60 (270.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
DuCal Solar Technology LLC DST270M-60
DuCal Solar Technology LLC
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
AXITEC AC-270P/60S
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
AXITEC AC-270P/60V
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-MLE270HD2?

Evaluate Mitsubishi Electric PV-MLE270HD2 (270.0 W STC, 38.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-MLE270HD2 reaches 44.22 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 471 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (471 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-MLE270HD2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitsubishi Electric PV-MLE270HD2 8 kW Residential Fit

Needs 30 modules (471 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM270M-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-MLE270HD2 by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

How many Mitsubishi Electric PV-MLE270HD2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Mitsubishi Electric PV-MLE270HD2 cold Voc rises from 38.4 V to 42.93 V (beta_Voc -0.337%/C), capping a 600 V string at 13 panels (558.1 V).

How much roof area does an 8 kW array of Mitsubishi Electric PV-MLE270HD2 need?

An 8 kW DC system uses 30 Mitsubishi Electric PV-MLE270HD2 modules (8,100 W STC / 7,284 W PTC), covering roughly 471 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Mitsubishi Electric PV-MLE270HD2 compare against Bluesun Solar Energy Tech CoLtd BSM270M-60?

Mitsubishi Electric PV-MLE270HD2 outputs 270.0 W STC (38.4 V Voc, rank #18,572 of 21,677), while Bluesun Solar Energy Tech CoLtd BSM270M-60 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.