DuCal Solar Technology LLC DST270M-60 is a 270.0 W STC (242.7 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.6% efficiency, 38.46 V Voc at 25 C, and 43.23 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 242.7 W
- Voc @ 25C
- 38.46 V
- Efficiency
- 16.6%
How Does DuCal Solar Technology LLC DST270M-60 Compare Against Peer CEC Listings?
How DuCal Solar Technology LLC DuCal Solar Technology LLC DST270M-60 handles rooftop heat (242.7 W PTC), 8 kW sizing, and cold winter string voltage.
DuCal Solar Technology LLC builds the DuCal Solar Technology LLC DST270M-60 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 165.9 W/m2 (3.31 percentage points below 19.91% CEC median). Compared against Bluesun Solar Energy Tech CoLtd BSM270M-60 (270.0 W), this model holds typical 89.9% PTC-to-STC thermal output (242.7 W real-world rating). Lower 38.46 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.31 A overcurrent floor served by a 15 A breaker.
Where Does DuCal Solar Technology LLC DST270M-60 Fall Across Listed CEC Models?
Where DuCal Solar Technology LLC DST270M-60 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define DuCal Solar Technology LLC DST270M-60?
Percentile placement of DuCal Solar Technology LLC DST270M-60 across power density (165.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for DuCal Solar Technology LLC DST270M-60?
Four critical engineering numbers homeowners and solar installers check first when reviewing DuCal Solar Technology LLC DST270M-60 specifications.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.6% Aperture Efficiency
Power density 165.9 W/m2 (3.31 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.23 V at -10 C (562.0 V string) and 44.59 V at -20 C (13 max).
30 Panels = 8,100 W STC
Occupies 48.8 m2 (525 sq ft) producing 7,281 W PTC; NEC 690.8 OCPD floor is 14.31 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.46 * (1 + (-0.354/100) * (-10 - 25)) = 43.23 V | OCPD = 1.56 * 9.17 = 14.31 A
Inputs from CEC Modules.csv for DuCal Solar Technology LLC DST270M-60: Voc=38.46 V, beta_Voc=-0.354%/C, Isc=9.17 A, STC=270.0 W, Area=1.627 m2.
Result: 13 panels max on 600 V (562.0 V); 30 panels for 8 kW (525 sq ft).
What Are the Published CEC Specifications for DuCal Solar Technology LLC DST270M-60?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for DuCal Solar Technology LLC DST270M-60.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 242.7 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.33 V / 8.62 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.354 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.6% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many DuCal Solar Technology LLC DST270M-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using DuCal Solar Technology LLC DST270M-60 (270.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 403 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 525 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 665 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This DuCal Solar Technology LLC Series?
All closely matched DuCal Solar Technology LLC wattages and cosmetic trims sharing the DuCal Solar Technology LLC DST270M-60 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| DuCal Solar Technology LLC DST265M-60 | 265.0 W | 238.1 W | 38.26 V | 31.11 V | 16.29% |
| DuCal Solar Technology LLC DST270M-60 | 270.0 W | 242.7 W | 38.46 V | 31.33 V | 16.6% |
How Many DuCal Solar Technology LLC DST270M-60 Modules Fit in a Cold-Weather String?
Maximum series module counts for DuCal Solar Technology LLC DST270M-60 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.59 V | 13 panels | 579.7 V | 22 panels |
| -10 C (14 F) | 43.23 V | 13 panels | 562.0 V | 23 panels |
| 0 C (32 F) | 41.86 V | 14 panels | 586.0 V | 23 panels |
| 25 C (77 F STC) | 38.46 V | 15 panels | 576.9 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to DuCal Solar Technology LLC DST270M-60?
Alternative CEC solar modules from competing brands near DuCal Solar Technology LLC DST270M-60 (270.0 W), including Bluesun Solar Energy Tech CoLtd BSM270M-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM270M-60 Bluesun Solar Energy Tech CoLtd |
270.0 W | Tie (0 W) | 38.46 V | 16.6% | 89.9% |
| Flextronics FXS-270BB-SAC1B Flextronics |
270.0 W | Tie (0 W) | 38.5 V | 16.45% | 91.3% |
| DEHUI SOLAR POWER INC DH-60M-270W DEHUI SOLAR POWER INC |
270.0 W | Tie (0 W) | 38.57 V | 16.77% | 91.1% |
| AXITEC AC-270P/60S AXITEC |
270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
What Are the Design Limits and Best-Fit Uses for DuCal Solar Technology LLC DST270M-60?
Evaluate DuCal Solar Technology LLC DST270M-60 (270.0 W STC, 38.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), DuCal Solar Technology LLC DST270M-60 reaches 44.59 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 525 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (525 sq ft).
- 2026 tax credit baseline: cash residential installs of DuCal Solar Technology LLC DST270M-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
DuCal Solar Technology LLC DST270M-60 8 kW Residential Fit
Needs 30 modules (525 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM270M-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for DuCal Solar Technology LLC DST270M-60 by DuCal Solar Technology LLC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for DuCal Solar Technology LLC DST270M-60?
Multiplying DuCal Solar Technology LLC DST270M-60's 9.17 A short-circuit current by 1.56 equals 14.31 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can DuCal Solar Technology LLC DST270M-60 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.23 V cold Voc at 14 F and handles 9.17 A Isc; string inverters cap DuCal Solar Technology LLC DST270M-60 at 13 panels on 600 V.
Is DuCal Solar Technology LLC DST270M-60 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of DuCal Solar Technology LLC DST270M-60 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)