Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-270P/60S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-270P/60S is a 270.0 W STC (248.9 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.56% efficiency, 38.31 V Voc at 25 C, and 42.32 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
248.9 W
Voc @ 25C
38.31 V
Efficiency
16.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-270P/60S Compare Against Peer CEC Listings?

Solar engineering breakdown for AXITEC AC-270P/60S: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Measured at 270.0 W STC and 248.9 W PTC, AXITEC AC-270P/60S sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 165.6 W/m2 (3.35 percentage points below 19.91% CEC median). Lower 38.31 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-P6/60270 rates 270.0 W.

Where Does AXITEC AC-270P/60S Fall Across Listed CEC Models?

Distribution marker showing AXITEC AC-270P/60S (270.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-270P/60S (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-270P/60S: 270.0 W

What Dataset Percentiles Define AXITEC AC-270P/60S?

Dataset percentiles tracking AXITEC AC-270P/60S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

AXITEC AC-270P/60S Engineering BenchmarksPercentile comparison of AXITEC AC-270P/60S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention92.2%Module Efficiency16.56%

What Do the Dataset Ranks Show for AXITEC AC-270P/60S?

Benchmark highlights for AXITEC AC-270P/60S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,195

16.56% Aperture Efficiency

Power density 165.6 W/m2 (3.35 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.32 V at -10 C (592.5 V string) and 43.46 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 48.9 m2 (526 sq ft) producing 7,467 W PTC; NEC 690.8 OCPD floor is 14.27 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.31 * (1 + (-0.299/100) * (-10 - 25)) = 42.32 V | OCPD = 1.56 * 9.15 = 14.27 A

Inputs from CEC Modules.csv for AXITEC AC-270P/60S: Voc=38.31 V, beta_Voc=-0.299%/C, Isc=9.15 A, STC=270.0 W, Area=1.63 m2.

Result: 14 panels max on 600 V (592.5 V); 30 panels for 8 kW (526 sq ft).

What Are the Published CEC Specifications for AXITEC AC-270P/60S?

Official CEC datasheet figures for AXITEC AC-270P/60S (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-270P/60S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 248.9 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.31 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.26 V / 8.64 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.299 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.56% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-270P/60S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many AXITEC AC-270P/60S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 404 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 526 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 667 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Consolidated AXITEC wattage variants sharing the AXITEC AC-270P/60S mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the AXITEC AC-270P/60S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-265P/60S 265.0 W 244.2 W 38.14 V 30.96 V 16.26%
AXITEC AC-270P/60S 270.0 W 248.9 W 38.31 V 31.26 V 16.56%

How Many AXITEC AC-270P/60S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-270P/60S (42.32 V at 14 F).

Computed from Voc=38.31V and beta_Voc=-0.299%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.46 V 13 panels 565.0 V 23 panels
-10 C (14 F) 42.32 V 14 panels 592.5 V 23 panels
0 C (32 F) 41.17 V 14 panels 576.4 V 24 panels
25 C (77 F STC) 38.31 V 15 panels 574.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-270P/60S?

Competing CEC solar panels closest to AXITEC AC-270P/60S in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/60270.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60270
GCL System Integration Technology Co Ltd
270.0 W Tie (0 W) 38.3 V 16.6% 90.6%
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
DuCal Solar Technology LLC DST270M-60
DuCal Solar Technology LLC
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
Flextronics FXS-270BB-SAC1B
Flextronics
270.0 W Tie (0 W) 38.5 V 16.45% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-270P/60S?

Evaluate AXITEC AC-270P/60S (270.0 W STC, 38.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-270P/60S reaches 43.46 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-270P/60S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-270P/60S 8 kW Residential Fit

Needs 30 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60270.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 248.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-270P/60S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-270P/60S panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-270P/60S cold Voc rises from 38.31 V to 42.32 V (beta_Voc -0.299%/C), capping a 600 V string at 14 panels (592.5 V).

How much roof area does an 8 kW array of AXITEC AC-270P/60S need?

An 8 kW DC system uses 30 AXITEC AC-270P/60S modules (8,100 W STC / 7,467 W PTC), covering roughly 526 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does AXITEC AC-270P/60S compare against GCL System Integration Technology Co Ltd GCL-P6/60270?

AXITEC AC-270P/60S outputs 270.0 W STC (38.31 V Voc, rank #18,572 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/60270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.