Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-270P/60V — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-270P/60V is a 270.0 W STC (248.9 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.56% efficiency, 38.31 V Voc at 25 C, and 42.32 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
248.9 W
Voc @ 25C
38.31 V
Efficiency
16.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-270P/60V Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-270P/60V (Multi-c-Si) residential solar systems.

AXITEC AC-270P/60V delivers 165.6 W/m2 (3.35 percentage points below 19.91% CEC median) and strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft). At -4 F (-20 C), string voltage climbs to 43.46 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with GCL System Integration Technology Co Ltd GCL-P6/60270 (270.0 W).

Where Does AXITEC AC-270P/60V Fall Across Listed CEC Models?

Comparison of AXITEC AC-270P/60V (270.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-270P/60V (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-270P/60V: 270.0 W

What Dataset Percentiles Define AXITEC AC-270P/60V?

Relative ranking of AXITEC AC-270P/60V across nameplate watts, 92.2% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AXITEC AC-270P/60V Engineering BenchmarksPercentile comparison of AXITEC AC-270P/60V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention92.2%Module Efficiency16.56%

What Do the Dataset Ranks Show for AXITEC AC-270P/60V?

Summary of AXITEC AC-270P/60V output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,195

16.56% Aperture Efficiency

Power density 165.6 W/m2 (3.35 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.32 V at -10 C (592.5 V string) and 43.46 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 48.9 m2 (526 sq ft) producing 7,467 W PTC; NEC 690.8 OCPD floor is 14.27 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.31 * (1 + (-0.299/100) * (-10 - 25)) = 42.32 V | OCPD = 1.56 * 9.15 = 14.27 A

Inputs from CEC Modules.csv for AXITEC AC-270P/60V: Voc=38.31 V, beta_Voc=-0.299%/C, Isc=9.15 A, STC=270.0 W, Area=1.63 m2.

Result: 14 panels max on 600 V (592.5 V); 30 panels for 8 kW (526 sq ft).

What Are the Published CEC Specifications for AXITEC AC-270P/60V?

Complete CEC test sheet for AXITEC AC-270P/60V including Isc (9.15 A), Voc (38.31 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-270P/60V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 248.9 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.31 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.26 V / 8.64 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.299 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.56% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-270P/60V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-270P/60V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 404 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 526 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 667 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-270P/60V series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the AXITEC AC-270P/60V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-265P/60V 265.0 W 244.2 W 38.14 V 30.96 V 16.26%
AXITEC AC-270P/60V 270.0 W 248.9 W 38.31 V 31.26 V 16.56%

How Many AXITEC AC-270P/60V Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-270P/60V (38.31 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.31V and beta_Voc=-0.299%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.46 V 13 panels 565.0 V 23 panels
-10 C (14 F) 42.32 V 14 panels 592.5 V 23 panels
0 C (32 F) 41.17 V 14 panels 576.4 V 24 panels
25 C (77 F STC) 38.31 V 15 panels 574.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-270P/60V?

Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-P6/60270 (270.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60270
GCL System Integration Technology Co Ltd
270.0 W Tie (0 W) 38.3 V 16.6% 90.6%
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
DuCal Solar Technology LLC DST270M-60
DuCal Solar Technology LLC
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
Flextronics FXS-270BB-SAC1B
Flextronics
270.0 W Tie (0 W) 38.5 V 16.45% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-270P/60V?

Evaluate AXITEC AC-270P/60V (270.0 W STC, 38.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-270P/60V reaches 43.46 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (526 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-270P/60V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-270P/60V 8 kW Residential Fit

Needs 30 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60270.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 248.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-270P/60V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-270P/60V panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-270P/60V cold Voc rises from 38.31 V to 42.32 V (beta_Voc -0.299%/C), capping a 600 V string at 14 panels (592.5 V).

How much roof area does an 8 kW array of AXITEC AC-270P/60V need?

An 8 kW DC system uses 30 AXITEC AC-270P/60V modules (8,100 W STC / 7,467 W PTC), covering roughly 526 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does AXITEC AC-270P/60V compare against GCL System Integration Technology Co Ltd GCL-P6/60270?

AXITEC AC-270P/60V outputs 270.0 W STC (38.31 V Voc, rank #18,572 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/60270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.