Skip to main content
WireAndSun
Calculators
CEC PV Module

Lightway Green New Energy LW175(23)P1310x990 — CEC Solar Module Specifications

Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW175(23)P1310x990 is a 175.0 W STC (156.5 W PTC) Multi-c-Si solar module ranking #21,282 of 21,677 CEC listings (below all-CEC median; higher than 1.6% of peers). It delivers 13.63% efficiency, 29.5 V Voc at 25 C, and 33.22 V cold Voc at -10 C (18 panels max per 600 V string).

STC Wattage
175.0 W
PTC Wattage
156.5 W
Voc @ 25C
29.5 V
Efficiency
13.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW175(23)P1310x990 Compare Against Peer CEC Listings?

Engineering position of Lightway Green New Energy LW175(23)P1310x990 (175.0 W STC) vs. Yingli Energy (China) YL180P-23b across 1,407 CEC Multi-c-Si solar modules.

Ranking #21,282 across 21,677 CEC solar panels (below all-CEC median; higher than 1.6% of peers), Lightway Green New Energy LW175(23)P1310x990 operates as a compact residential or specialty off-grid module sitting 103.8 W below the 278.8 W Multi-c-Si median. Lower 29.5 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters. With typical 89.4% PTC-to-STC thermal output (156.5 W real-world rating), 46 panels occupy 636 sq ft and offset roughly $2,015/yr at average US rates (or $3,407/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Lightway Green New Energy LW175(23)P1310x990 Fall Across Listed CEC Models?

Plots Lightway Green New Energy LW175(23)P1310x990 at 175.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW175(23)P1310x990 (175.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 175.0 W

What Dataset Percentiles Define Lightway Green New Energy LW175(23)P1310x990?

Benchmarks Lightway Green New Energy LW175(23)P1310x990 on STC wattage, thermal PTC/STC retention, and 13.63 aperture conversion efficiency against CEC peers.

Lightway Green New Energy LW175(23)P1310x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW175(23)P1310x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage175.0 WPTC/STC Retention89.4%Module Efficiency13.63%

What Do the Dataset Ranks Show for Lightway Green New Energy LW175(23)P1310x990?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Lightway Green New Energy LW175(23)P1310x990 by Lightway Green New Energy.

Rank #21,282 / 21,677

175.0 W STC · Higher Than 1.6%

175.0 W STC (-210.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,144

13.63% Aperture Efficiency

Power density 136.3 W/m2 (6.28 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

18 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.22 V at -10 C (598.0 V string) and 34.28 V at -20 C (17 max).

8 kW Reference Array

46 Panels = 8,050 W STC

Occupies 59.1 m2 (636 sq ft) producing 7,199 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.5 * (1 + (-0.36/100) * (-10 - 25)) = 33.22 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW175(23)P1310x990: Voc=29.5 V, beta_Voc=-0.36%/C, Isc=8.2 A, STC=175.0 W, Area=1.284 m2.

Result: 18 panels max on 600 V (598.0 V); 46 panels for 8 kW (636 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW175(23)P1310x990?

Laboratory test ratings recorded for Lightway Green New Energy LW175(23)P1310x990 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW175(23)P1310x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 175.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 156.5 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 29.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 23.0 V / 7.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.63% (1.284 m2) Array roof footprint density
Cell Count & Technology 48 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW175(23)P1310x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (636 sq ft at 8 kW), and estimated Year-1 electric bill offset for Lightway Green New Energy LW175(23)P1310x990.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 35 6.12 kW 484 sq ft $1,532 $2,590
8 kW Class 46 8.05 kW 636 sq ft $2,015 $3,407
10 kW Class 58 10.15 kW 802 sq ft $2,540 $4,296

How Many Lightway Green New Energy LW175(23)P1310x990 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Lightway Green New Energy LW175(23)P1310x990 (beta_Voc -0.36%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=29.5V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.28 V 17 panels 582.8 V 29 panels
-10 C (14 F) 33.22 V 18 panels 598.0 V 30 panels
0 C (32 F) 32.16 V 18 panels 578.9 V 31 panels
25 C (77 F STC) 29.5 V 20 panels 590.0 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW175(23)P1310x990?

Closest cross-brand CEC competitors to Lightway Green New Energy LW175(23)P1310x990 matched near 175.0 W STC and 29.5 V Voc, led by Yingli Energy (China) YL180P-23b.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Yingli Energy (China) YL180P-23b
Yingli Energy (China)
180.0 W +5.0 W 29.5 V 14.02% 90.8%
Gintung Energy ASEC-180G6M
Gintung Energy
180.0 W +5.0 W 29.51 V 13.8% 89.2%
Guangdong Golden Glass Technologies GG180M2-24/1324x992
Guangdong Golden Glass Technologies
180.0 W +5.0 W 29.4 V 13.7% 89.9%
APOS Energy AP180
APOS Energy
180.0 W +5.0 W 29.72 V 13.42% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW175(23)P1310x990?

Evaluate Lightway Green New Energy LW175(23)P1310x990 (175.0 W STC, 29.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW175(23)P1310x990 reaches 34.28 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 46 panels for an 8 kW build require 636 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 46 panels (636 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW175(23)P1310x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW175(23)P1310x990 8 kW Residential Fit

Needs 46 modules (636 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Yingli Energy (China) YL180P-23b.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 156.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW175(23)P1310x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Lightway Green New Energy LW175(23)P1310x990 panels fit on a 600 V winter solar string?

At -10 C (14 F), Lightway Green New Energy LW175(23)P1310x990 cold Voc rises from 29.5 V to 33.22 V (beta_Voc -0.36%/C), capping a 600 V string at 18 panels (598.0 V).

How much roof area does an 8 kW array of Lightway Green New Energy LW175(23)P1310x990 need?

An 8 kW DC system uses 46 Lightway Green New Energy LW175(23)P1310x990 modules (8,050 W STC / 7,199 W PTC), covering roughly 636 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

How does Lightway Green New Energy LW175(23)P1310x990 compare against Yingli Energy (China) YL180P-23b?

Lightway Green New Energy LW175(23)P1310x990 outputs 175.0 W STC (29.5 V Voc, rank #21,282 of 21,677), while Yingli Energy (China) YL180P-23b delivers 180.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.