Skip to main content
WireAndSun
Calculators
CEC PV Module

Sunflare Co FLEX60-165W-M20-A — CEC Solar Module Specifications

Manufacturer: Sunflare Co Registry: CEC Verified Engineering Specification

Sunflare Co FLEX60-165W-M20-A is a 165.0 W STC (142.9 W PTC) Thin Film solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 10.06% efficiency, 35.42 V Voc at 25 C, and 39.3 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
165.0 W
PTC Wattage
142.9 W
Voc @ 25C
35.42 V
Efficiency
10.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunflare Co FLEX60-165W-M20-A Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunflare Co FLEX60-165W-M20-A: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Measured at 165.0 W STC and 142.9 W PTC, Sunflare Co FLEX60-165W-M20-A sits -220.0 W vs all-CEC median (below all-CEC median; higher than 1.4% of peers) among 21,677 listed modules. Power density reaches 100.6 W/m2 (9.85 percentage points below 19.91% CEC median). Lower 35.42 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 25 panels in series. Alternative peer Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 rates 170.0 W.

Where Does Sunflare Co FLEX60-165W-M20-A Fall Across Listed CEC Models?

Distribution marker showing Sunflare Co FLEX60-165W-M20-A (165.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunflare Co FLEX60-165W-M20-A (165.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunflare Co FLEX60: 165.0 W

What Dataset Percentiles Define Sunflare Co FLEX60-165W-M20-A?

Dataset percentiles tracking Sunflare Co FLEX60-165W-M20-A power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sunflare Co FLEX60-165W-M20-A Engineering BenchmarksPercentile comparison of Sunflare Co FLEX60-165W-M20-A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage165.0 WPTC/STC Retention86.6%Module Efficiency10.06%

What Do the Dataset Ranks Show for Sunflare Co FLEX60-165W-M20-A?

Benchmark highlights for Sunflare Co FLEX60-165W-M20-A covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #21,351 / 21,677

165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,625

10.06% Aperture Efficiency

Power density 100.6 W/m2 (9.85 percentage points below 19.91% CEC median). PTC/STC ratio: 86.6% (rank #21,610).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.3 V at -10 C (589.5 V string) and 40.41 V at -20 C (14 max).

8 kW Reference Array

49 Panels = 8,085 W STC

Occupies 80.4 m2 (865 sq ft) producing 7,002 W PTC; NEC 690.8 OCPD floor is 11.36 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.42 * (1 + (-0.313/100) * (-10 - 25)) = 39.3 V | OCPD = 1.56 * 7.28 = 11.36 A

Inputs from CEC Modules.csv for Sunflare Co FLEX60-165W-M20-A: Voc=35.42 V, beta_Voc=-0.313%/C, Isc=7.28 A, STC=165.0 W, Area=1.64 m2.

Result: 15 panels max on 600 V (589.5 V); 49 panels for 8 kW (865 sq ft).

What Are the Published CEC Specifications for Sunflare Co FLEX60-165W-M20-A?

Official CEC datasheet figures for Sunflare Co FLEX60-165W-M20-A (Thin Film) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Sunflare Co FLEX60-165W-M20-A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 165.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 142.9 W (86.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.42 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.28 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.5 V / 6.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 10.06% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Thin Film) Monofacial backsheet

How Many Sunflare Co FLEX60-165W-M20-A Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunflare Co FLEX60-165W-M20-A modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 37 6.11 kW 653 sq ft $1,529 $2,586
8 kW Class 49 8.09 kW 865 sq ft $2,025 $3,424
10 kW Class 61 10.06 kW 1,077 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Sunflare Co Series?

Consolidated Sunflare Co wattage variants sharing the Sunflare Co FLEX60-165W-M20-A mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Sunflare Co FLEX60-165W-M20-A wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Sunflare Co FLEX60-160W-M20-A 160.0 W 138.5 W 35.11 V 27.63 V 9.76%
Sunflare Co FLEX60-165W-M20-A 165.0 W 142.9 W 35.42 V 27.5 V 10.06%
Sunflare Co FLEX60-170W-M20-A 170.0 W 147.3 W 35.74 V 27.37 V 10.37%

How Many Sunflare Co FLEX60-165W-M20-A Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunflare Co FLEX60-165W-M20-A (39.3 V at 14 F).

Computed from Voc=35.42V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 40.41 V 14 panels 565.7 V 24 panels
-10 C (14 F) 39.3 V 15 panels 589.5 V 25 panels
0 C (32 F) 38.19 V 15 panels 572.8 V 26 panels
25 C (77 F STC) 35.42 V 16 panels 566.7 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to Sunflare Co FLEX60-165W-M20-A?

Competing CEC solar panels closest to Sunflare Co FLEX60-165W-M20-A in nameplate wattage and Voc, starting with Hanwha Qcells (Qidong) Co Ltd SF190-27-P170.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd SF190-27-P170
Hanwha Qcells (Qidong) Co Ltd
170.0 W +5.0 W 32.2 V 11.38% 88.5%
Lightway Green New Energy LW165(23)P1310x990
Lightway Green New Energy
165.0 W Tie (0 W) 29.0 V 10.19% 88.8%
Juli New Energy JLS165M
Juli New Energy
165.0 W Tie (0 W) 42.0 V 12.92% 85.8%
Guangdong Golden Glass Technologies GG165M2-24/1324x992
Guangdong Golden Glass Technologies
165.0 W Tie (0 W) 28.8 V 12.56% 89.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunflare Co FLEX60-165W-M20-A?

Evaluate Sunflare Co FLEX60-165W-M20-A (165.0 W STC, 35.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunflare Co FLEX60-165W-M20-A reaches 40.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 49 panels for an 8 kW build require 865 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (865 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunflare Co FLEX60-165W-M20-A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunflare Co FLEX60-165W-M20-A 8 kW Residential Fit

Needs 49 modules (865 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF190-27-P170.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 142.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunflare Co FLEX60-165W-M20-A by Sunflare Co grounded in CEC test data and NEC 690.7/690.8 limits.

How many Sunflare Co FLEX60-165W-M20-A panels fit on a 600 V winter solar string?

At -10 C (14 F), Sunflare Co FLEX60-165W-M20-A cold Voc rises from 35.42 V to 39.3 V (beta_Voc -0.313%/C), capping a 600 V string at 15 panels (589.5 V).

How much roof area does an 8 kW array of Sunflare Co FLEX60-165W-M20-A need?

An 8 kW DC system uses 49 Sunflare Co FLEX60-165W-M20-A modules (8,085 W STC / 7,002 W PTC), covering roughly 865 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does Sunflare Co FLEX60-165W-M20-A compare against Hanwha Qcells (Qidong) Co Ltd SF190-27-P170?

Sunflare Co FLEX60-165W-M20-A outputs 165.0 W STC (35.42 V Voc, rank #21,351 of 21,677), while Hanwha Qcells (Qidong) Co Ltd SF190-27-P170 delivers 170.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls