Sunflare Co FLEX20-60W is a 60.0 W STC (54.1 W PTC) Thin Film solar module ranking #21,652 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 10.17% efficiency, 12.5 V Voc at 25 C, and 13.93 V cold Voc at -10 C (43 panels max per 600 V string).
- STC Wattage
- 60.0 W
- PTC Wattage
- 54.1 W
- Voc @ 25C
- 12.5 V
- Efficiency
- 10.17%
How Does Sunflare Co FLEX20-60W Compare Against Peer CEC Listings?
Solar engineering breakdown for Sunflare Co FLEX20-60W: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Across 106 Thin Film listings from Sunflare Co and peers, Sunflare Co FLEX20-60W stands 57.5 W below the 117.5 W Thin Film median and typical 90.2% PTC-to-STC thermal output (54.1 W real-world rating). Sizing 6 kW (100 panels) to 10 kW (167 panels) yields $1,502-$2,508/yr in baseline US bill offset. Lower 12.5 V string voltage fits 43 panels in series at 14 F and pairs easily with microinverters.
Where Does Sunflare Co FLEX20-60W Fall Across Listed CEC Models?
Distribution marker showing Sunflare Co FLEX20-60W (60.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define Sunflare Co FLEX20-60W?
Dataset percentiles tracking Sunflare Co FLEX20-60W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for Sunflare Co FLEX20-60W?
Benchmark highlights for Sunflare Co FLEX20-60W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
60.0 W STC · Higher Than 0.1%
60.0 W STC (-325.0 W vs all-CEC median) vs 117.5 W Thin Film median.
10.17% Aperture Efficiency
Power density 101.7 W/m2 (9.74 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
43 Panels Max @ -10 C (600 V)
Cold Voc reaches 13.93 V at -10 C (599.0 V string) and 14.34 V at -20 C (41 max).
134 Panels = 8,040 W STC
Occupies 79.1 m2 (851 sq ft) producing 7,249 W PTC; NEC 690.8 OCPD floor is 11.54 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 12.5 * (1 + (-0.327/100) * (-10 - 25)) = 13.93 V | OCPD = 1.56 * 7.4 = 11.54 A
Inputs from CEC Modules.csv for Sunflare Co FLEX20-60W: Voc=12.5 V, beta_Voc=-0.327%/C, Isc=7.4 A, STC=60.0 W, Area=0.59 m2.
Result: 43 panels max on 600 V (599.0 V); 134 panels for 8 kW (851 sq ft).
What Are the Published CEC Specifications for Sunflare Co FLEX20-60W?
Official CEC datasheet figures for Sunflare Co FLEX20-60W (Thin Film) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 60.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 54.1 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 12.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 9.5 V / 6.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.327 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 10.17% (0.59 m2) | Array roof footprint density |
| Cell Count & Technology | 20 cells (Thin Film) | Monofacial backsheet |
How Many Sunflare Co FLEX20-60W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Sunflare Co FLEX20-60W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 100 | 6.0 kW | 635 sq ft | $1,502 | $2,539 |
| 8 kW Class | 134 | 8.04 kW | 851 sq ft | $2,012 | $3,403 |
| 10 kW Class | 167 | 10.02 kW | 1,061 sq ft | $2,508 | $4,241 |
How Many Sunflare Co FLEX20-60W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Sunflare Co FLEX20-60W (13.93 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 14.34 V | 41 panels | 587.9 V | 69 panels |
| -10 C (14 F) | 13.93 V | 43 panels | 599.0 V | 71 panels |
| 0 C (32 F) | 13.52 V | 44 panels | 594.9 V | 73 panels |
| 25 C (77 F STC) | 12.5 V | 48 panels | 600.0 V | 80 panels |
Which Cross-Brand Solar Modules Compare Closest to Sunflare Co FLEX20-60W?
Competing CEC solar panels closest to Sunflare Co FLEX20-60W in nameplate wattage and Voc, starting with Tesla Inc SR60T1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Tesla Inc SR60T1 Tesla Inc |
58.5 W | -1.5 W | 13.34 V | 11.93% | 89.1% |
| Midsummer AB SLIM 2 x 10 65 Midsummer AB |
65.0 W | +5.0 W | 12.6 V | 10.0% | 82.5% |
| GAF Energy LLC TLS-2-58 GAF Energy LLC |
58.0 W | -2.0 W | 11.04 V | 8.29% | 86.0% |
| GAF Energy LLC TLS-2J-58 GAF Energy LLC |
58.0 W | -2.0 W | 11.04 V | 8.29% | 86.0% |
What Are the Design Limits and Best-Fit Uses for Sunflare Co FLEX20-60W?
Evaluate Sunflare Co FLEX20-60W (60.0 W STC, 12.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sunflare Co FLEX20-60W reaches 14.34 V per panel—exceeding 41 panels in series voids 600 V inverter warranties.
- Footprint constraint: 134 panels for an 8 kW build require 851 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 134 panels (851 sq ft).
- 2026 tax credit baseline: cash residential installs of Sunflare Co FLEX20-60W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sunflare Co FLEX20-60W 8 kW Residential Fit
Needs 134 modules (851 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 43 panels (-10 C) or 41 panels (-20 C), or compare Tesla Inc SR60T1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 54.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sunflare Co FLEX20-60W by Sunflare Co grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sunflare Co FLEX20-60W?
Multiplying Sunflare Co FLEX20-60W's 7.4 A short-circuit current by 1.56 equals 11.54 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Sunflare Co FLEX20-60W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 13.93 V cold Voc at 14 F and handles 7.4 A Isc; string inverters cap Sunflare Co FLEX20-60W at 43 panels on 600 V.
Is Sunflare Co FLEX20-60W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunflare Co FLEX20-60W rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)