Tesla Inc SR60T1 is a 58.5 W STC (52.1 W PTC) Multi-c-Si solar module ranking #21,653 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 11.93% efficiency, 13.34 V Voc at 25 C, and 14.74 V cold Voc at -10 C (40 panels max per 600 V string).

STC Wattage
58.5 W
PTC Wattage
52.1 W
Voc @ 25C
13.34 V
Efficiency
11.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Tesla Inc SR60T1 Compare Against Peer CEC Listings?

How Tesla Inc Tesla Inc SR60T1 handles rooftop heat (52.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Tesla Inc SR60T1 exhibits 5.65 A short-circuit current, requiring a 8.81 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,653 of 21,677 (220.3 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 67.1 m2 for an 8 kW system (171 panels for 10 kW). Lower 13.34 V string voltage fits 40 panels in series at 14 F and pairs easily with microinverters.

Where Does Tesla Inc SR60T1 Fall Across Listed CEC Models?

Where Tesla Inc SR60T1 (58.5 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Tesla Inc SR60T1 (58.5 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTesla Inc SR60T1: 58.5 W

What Dataset Percentiles Define Tesla Inc SR60T1?

Percentile placement of Tesla Inc SR60T1 across power density (119.4 W/m2), thermal retention, and nameplate STC wattage.

Tesla Inc SR60T1 Engineering BenchmarksPercentile comparison of Tesla Inc SR60T1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage58.5 WPTC/STC Retention89.1%Module Efficiency11.93%

What Do the Dataset Ranks Show for Tesla Inc SR60T1?

Four critical engineering numbers homeowners and solar installers check first when reviewing Tesla Inc SR60T1 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #21,653 / 21,677

58.5 W STC · Higher Than 0.1%

58.5 W STC (-326.5 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,578

11.93% Aperture Efficiency

Power density 119.4 W/m2 (7.98 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

40 Panels Max @ -10 C (600 V)

Cold Voc reaches 14.74 V at -10 C (589.6 V string) and 15.13 V at -20 C (39 max).

8 kW Reference Array

137 Panels = 8,014 W STC

Occupies 67.1 m2 (723 sq ft) producing 7,138 W PTC; NEC 690.8 OCPD floor is 8.81 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 13.34 * (1 + (-0.299/100) * (-10 - 25)) = 14.74 V | OCPD = 1.56 * 5.65 = 8.81 A

Inputs from CEC Modules.csv for Tesla Inc SR60T1: Voc=13.34 V, beta_Voc=-0.299%/C, Isc=5.65 A, STC=58.5 W, Area=0.49 m2.

Result: 40 panels max on 600 V (589.6 V); 137 panels for 8 kW (723 sq ft).

What Are the Published CEC Specifications for Tesla Inc SR60T1?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Tesla Inc SR60T1.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc SR60T1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 58.5 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 52.1 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 13.34 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 10.99 V / 5.32 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.299 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 11.93% (0.49 m2) Array roof footprint density
Cell Count & Technology 21 cells (Multi-c-Si) Monofacial backsheet

How Many Tesla Inc SR60T1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Tesla Inc SR60T1 (58.5 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 103 6.03 kW 543 sq ft $1,509 $2,552
8 kW Class 137 8.01 kW 723 sq ft $2,005 $3,390
10 kW Class 171 10.0 kW 902 sq ft $2,503 $4,232

How Many Tesla Inc SR60T1 Modules Fit in a Cold-Weather String?

Maximum series module counts for Tesla Inc SR60T1 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=13.34V and beta_Voc=-0.299%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 15.13 V 39 panels 590.1 V 66 panels
-10 C (14 F) 14.74 V 40 panels 589.6 V 67 panels
0 C (32 F) 14.34 V 41 panels 587.9 V 69 panels
25 C (77 F STC) 13.34 V 44 panels 587.0 V 74 panels

Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR60T1?

Alternative CEC solar modules from competing brands near Tesla Inc SR60T1 (58.5 W), including Sunflare Co FLEX20-60W. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Sunflare Co FLEX20-60W
Sunflare Co
60.0 W +1.5 W 12.5 V 10.17% 90.2%
Ergosun Holdings LLC Ergosun 55W
Ergosun Holdings LLC
55.0 W -3.5 W 14.5 V 19.64% 94.9%
Sunflare Co FLEX20-55W
Sunflare Co
55.0 W -3.5 W 12.0 V 9.32% 90.0%
Midsummer AB SLIM 2 x 10 65
Midsummer AB
65.0 W +6.5 W 12.6 V 10.0% 82.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Tesla Inc SR60T1?

Evaluate Tesla Inc SR60T1 (58.5 W STC, 13.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR60T1 reaches 15.13 V per panel—exceeding 39 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 137 panels for an 8 kW build require 723 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 137 panels (723 sq ft).
  • 2026 tax credit baseline: cash residential installs of Tesla Inc SR60T1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Tesla Inc SR60T1 8 kW Residential Fit

Needs 137 modules (723 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 40 panels (-10 C) or 39 panels (-20 C), or compare Sunflare Co FLEX20-60W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 52.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc SR60T1 by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Tesla Inc SR60T1 PTC wattage (52.1 W) lower than STC (58.5 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 52.1 W PTC (89.1% retention) across Tesla Inc SR60T1's 0.49 m2 aperture.

Who should skip Tesla Inc SR60T1 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 137 Tesla Inc SR60T1 panels (723 sq ft) leave unusable roof gaps vs. Sunflare Co FLEX20-60W.

What is the 1,000 V commercial string limit for Tesla Inc SR60T1?

On 1,000 V commercial inverters at -10 C (14.74 V cold Voc), Tesla Inc SR60T1 fits up to 67 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc SR60T1.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.