Skip to main content
WireAndSun
Calculators
CEC Brand Hub

Tesla Inc — CEC Certified Solar Equipment Catalog

Registry: California Energy Commission (CEC) Verified: 2026-11-26

Tesla Inc holds 23 verified California Energy Commission (CEC) certifications including 17 module series and 6 grid-support inverter models (23–430W PV / 3,336–11,508W AC). Tesla Inc carries 17 module series ranging from 23 W to 430 W STC (median 73 W vs 385 W CEC fleet median; 16.2% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si).

Manufacturer
Tesla Inc
PV Module Series
17
Listed Inverters
6
Output Range
23–430W PV / 3,336–11,508W AC
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Do Tesla Inc Solar Specifications Compare Across the CEC Catalog?

How Tesla Inc residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Tesla Inc for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Tesla Inc carries 17 module series ranging from 23 W to 430 W STC (median 73 W vs 385 W CEC fleet median; 16.2% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). On the AC conversion side, Tesla Inc lists 6 CEC-certified inverters from 3,336 W to 11,508 W AC (97.4% median weighted CEC efficiency, including 2 battery-ready hybrid units). No active CPSC electrical recalls match Tesla Inc in our federal recall archive as of 2026.

Which Tesla Inc PV Module Series Are CEC Certified? (17)

Inspect Tesla Inc photovoltaic panel series sorted from highest STC wattage downward; near-identical wattage trims are grouped inside each series page.

Deduplicated CEC photovoltaic module series for Tesla Inc.
Module Series STC (W) PTC (W) Voc (V) Eff (%) Variants
Tesla Inc T430S 430.0 401.8 48.8 20.37 2
Tesla Inc TSP-430 430.0 405.0 41.01 21.18 2
Tesla Inc T420S 420.0 392.2 48.5 19.9 1
Tesla Inc TSP-415 415.0 390.6 40.92 20.44 4
Tesla Inc T400H 400.0 371.5 45.3 20.83 3
Tesla Inc T395H 395.0 366.7 45.27 20.57 1
Tesla Inc SR86T3R 86.0 77.3 26.6 17.92 1
Tesla Inc SR75T3R 75.0 67.9 14.2 16.67 1
Tesla Inc SR73T3R 73.0 66.0 14.2 16.22 1
Tesla Inc SR72T1 72.0 65.4 14.2 14.69 1
Tesla Inc SR72T2 72.0 65.4 14.2 14.69 1
Tesla Inc SR72T3R 72.0 65.4 14.2 14.69 1
Tesla Inc SR60T1 58.5 52.1 13.34 11.93 1
Tesla Inc SR25S3 25.0 22.3 4.3 10.58 1
Tesla Inc SR25T3 25.0 21.9 4.3 10.56 1
Tesla Inc SR24S3-2 23.8 20.5 3.8 9.9 1
Tesla Inc SR24T3-2 23.8 20.5 3.8 9.9 1

Which Tesla Inc Grid-Support Inverters Are Listed? (6)

Compare CEC-certified Tesla Inc inverters by continuous AC output watts, nominal grid voltage, maximum DC input ceiling, and weighted test efficiency.

Verified CEC grid-support inverters from Tesla Inc.
Inverter Model AC Output (W) Vac (V) Max DC (V) CEC Eff (%)
Tesla Inc: 1707000-XX-Y {240V 115kW} 11,508 240.0 480.0 97.19
Tesla Inc: 1707000-XX-Y {240V 10kW} 9,991 240.0 480.0 95.82
Tesla Inc: 1538000-xx-y {240V} 7,575 240.0 480.0 97.54
Tesla Inc: 1538000-xx-y {208V} 6,561 208.0 480.0 97.37
Tesla Inc: 1534000-xx-y {240V} 3,800 240.0 425.0 97.61
Tesla Inc: 1534000-xx-y {208V} 3,336 208.0 480.0 97.42
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Tesla Inc Solar Hardware?

Evaluate Tesla Inc CEC certifications (23–430W PV / 3,336–11,508W AC), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

  • With 17 module series and 6 inverter models, verify your exact wattage trim appears on your utility's accepted CEC sub-revision before permitting.
  • Constrained roofs: Tesla Inc's median module aperture efficiency (16.2%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

Unified Tesla Inc Solar + Inverter Spec

Use Tesla Inc modules and inverters together under unified CEC certification tracking while verifying NEC 705.12 backfeed clearance.

Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Tesla Inc solar equipment. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many Tesla Inc solar models are verified on the CEC list?

Our CEC archive indexes 23 Tesla Inc equipment records (17 module series and 6 inverter models) spanning 23–430W PV / 3,336–11,508W AC. Check local building department permit requirements for Tesla Inc before finalizing component orders.

What should homeowners check before approving Tesla Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

How efficient are Tesla Inc solar panels compared to CEC averages?

Across listed series, Tesla Inc modules show a median aperture efficiency of 16.2% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
  4. CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.