Skip to main content
WireAndSun
Calculators
CEC PV Module

Tesla Inc SR24S3-2 — CEC Solar Module Specifications

Manufacturer: Tesla Inc Registry: CEC Verified Engineering Specification

Tesla Inc SR24S3-2 is a 23.8 W STC (20.5 W PTC) Multi-c-Si solar module ranking #21,675 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 9.9% efficiency, 3.8 V Voc at 25 C, and 4.23 V cold Voc at -10 C (141 panels max per 600 V string).

STC Wattage
23.8 W
PTC Wattage
20.5 W
Voc @ 25C
3.8 V
Efficiency
9.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Tesla Inc SR24S3-2 Compare Against Peer CEC Listings?

How Tesla Inc Tesla Inc SR24S3-2 handles rooftop heat (20.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Tesla Inc SR24S3-2 exhibits 8.35 A short-circuit current, requiring a 13.03 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,675 of 21,677 (255.0 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 80.9 m2 for an 8 kW system (421 panels for 10 kW). Lower 3.8 V string voltage fits 141 panels in series at 14 F and pairs easily with microinverters.

Where Does Tesla Inc SR24S3-2 Fall Across Listed CEC Models?

Where Tesla Inc SR24S3-2 (23.8 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Tesla Inc SR24S3-2 (23.8 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTesla Inc SR24S3-2: 23.8 W

What Dataset Percentiles Define Tesla Inc SR24S3-2?

Percentile placement of Tesla Inc SR24S3-2 across power density (99.2 W/m2), thermal retention, and nameplate STC wattage.

Tesla Inc SR24S3-2 Engineering BenchmarksPercentile comparison of Tesla Inc SR24S3-2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage23.8 WPTC/STC Retention86.3%Module Efficiency9.9%

What Do the Dataset Ranks Show for Tesla Inc SR24S3-2?

Four critical engineering numbers homeowners and solar installers check first when reviewing Tesla Inc SR24S3-2 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #21,675 / 21,677

23.8 W STC · Higher Than 0.0%

23.8 W STC (-361.2 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,629

9.9% Aperture Efficiency

Power density 99.2 W/m2 (10.01 percentage points below 19.91% CEC median). PTC/STC ratio: 86.3% (rank #21,635).

NEC 690.7 Limit

141 Panels Max @ -10 C (600 V)

Cold Voc reaches 4.23 V at -10 C (596.4 V string) and 4.36 V at -20 C (137 max).

8 kW Reference Array

337 Panels = 8,021 W STC

Occupies 80.9 m2 (871 sq ft) producing 6,908 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 3.8 * (1 + (-0.325/100) * (-10 - 25)) = 4.23 V | OCPD = 1.56 * 8.35 = 13.03 A

Inputs from CEC Modules.csv for Tesla Inc SR24S3-2: Voc=3.8 V, beta_Voc=-0.325%/C, Isc=8.35 A, STC=23.8 W, Area=0.24 m2.

Result: 141 panels max on 600 V (596.4 V); 337 panels for 8 kW (871 sq ft).

What Are the Published CEC Specifications for Tesla Inc SR24S3-2?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Tesla Inc SR24S3-2.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc SR24S3-2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 23.8 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 20.5 W (86.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 3.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 3.04 V / 7.8 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.325 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 9.9% (0.24 m2) Array roof footprint density
Cell Count & Technology 6 cells (Multi-c-Si) Monofacial backsheet

How Many Tesla Inc SR24S3-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Tesla Inc SR24S3-2 (23.8 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 253 6.02 kW 654 sq ft $1,507 $2,548
8 kW Class 337 8.02 kW 871 sq ft $2,007 $3,394
10 kW Class 421 10.02 kW 1,088 sq ft $2,508 $4,241

How Many Tesla Inc SR24S3-2 Modules Fit in a Cold-Weather String?

Maximum series module counts for Tesla Inc SR24S3-2 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=3.8V and beta_Voc=-0.325%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 4.36 V 137 panels 597.3 V 229 panels
-10 C (14 F) 4.23 V 141 panels 596.4 V 236 panels
0 C (32 F) 4.11 V 145 panels 596.0 V 243 panels
25 C (77 F STC) 3.8 V 157 panels 596.6 V 263 panels

Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR24S3-2?

Alternative CEC solar modules from competing brands near Tesla Inc SR24S3-2 (23.8 W), including Jackery Inc JS-36A. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Jackery Inc JS-36A
Jackery Inc
36.0 W +12.2 W 5.54 V 12.29% 90.8%
Jackery Inc JS-38A
Jackery Inc
38.0 W +14.2 W 5.54 V 12.97% 91.1%
Jackery Inc JS-42A
Jackery Inc
42.0 W +18.2 W 5.54 V 14.33% 92.4%
Jackery Inc JS-45A
Jackery Inc
45.0 W +21.2 W 5.54 V 15.36% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Tesla Inc SR24S3-2?

Evaluate Tesla Inc SR24S3-2 (23.8 W STC, 3.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR24S3-2 reaches 4.36 V per panel—exceeding 137 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 337 panels for an 8 kW build require 871 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 337 panels (871 sq ft).
  • 2026 tax credit baseline: cash residential installs of Tesla Inc SR24S3-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Tesla Inc SR24S3-2 8 kW Residential Fit

Needs 337 modules (871 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 141 panels (-10 C) or 137 panels (-20 C), or compare Jackery Inc JS-36A.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 20.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc SR24S3-2 by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Tesla Inc SR24S3-2 PTC wattage (20.5 W) lower than STC (23.8 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 20.5 W PTC (86.3% retention) across Tesla Inc SR24S3-2's 0.24 m2 aperture.

Who should skip Tesla Inc SR24S3-2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 337 Tesla Inc SR24S3-2 panels (871 sq ft) leave unusable roof gaps vs. Jackery Inc JS-36A.

What is the 1,000 V commercial string limit for Tesla Inc SR24S3-2?

On 1,000 V commercial inverters at -10 C (4.23 V cold Voc), Tesla Inc SR24S3-2 fits up to 236 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc SR24S3-2.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.