Manufacturer: Jackery Inc Registry: CEC Verified Engineering Specification

Jackery Inc JS-36A is a 36.0 W STC (32.7 W PTC) Mono-c-Si solar module ranking #21,672 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 12.29% efficiency, 5.54 V Voc at 25 C, and 6.14 V cold Voc at -10 C (97 panels max per 600 V string).

STC Wattage
36.0 W
PTC Wattage
32.7 W
Voc @ 25C
5.54 V
Efficiency
12.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jackery Inc JS-36A Compare Against Peer CEC Listings?

How Jackery Inc Jackery Inc JS-36A handles rooftop heat (32.7 W PTC), 8 kW sizing, and cold winter string voltage.

Jackery Inc builds the Jackery Inc JS-36A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 122.9 W/m2 (7.62 percentage points below 19.91% CEC median). Compared against Tesla Inc SR25S3 (25.0 W), this model holds typical 90.8% PTC-to-STC thermal output (32.7 W real-world rating). Lower 5.54 V string voltage fits 97 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.81 A overcurrent floor served by a 15 A breaker.

Where Does Jackery Inc JS-36A Fall Across Listed CEC Models?

Where Jackery Inc JS-36A (36.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jackery Inc JS-36A (36.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJackery Inc JS-36A: 36.0 W

What Dataset Percentiles Define Jackery Inc JS-36A?

Percentile placement of Jackery Inc JS-36A across power density (122.9 W/m2), thermal retention, and nameplate STC wattage.

Jackery Inc JS-36A Engineering BenchmarksPercentile comparison of Jackery Inc JS-36A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage36.0 WPTC/STC Retention90.8%Module Efficiency12.29%

What Do the Dataset Ranks Show for Jackery Inc JS-36A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jackery Inc JS-36A specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,672 / 21,677

36.0 W STC · Higher Than 0.0%

36.0 W STC (-349.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,549

12.29% Aperture Efficiency

Power density 122.9 W/m2 (7.62 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

97 Panels Max @ -10 C (600 V)

Cold Voc reaches 6.14 V at -10 C (595.6 V string) and 6.32 V at -20 C (94 max).

8 kW Reference Array

223 Panels = 8,028 W STC

Occupies 65.3 m2 (703 sq ft) producing 7,292 W PTC; NEC 690.8 OCPD floor is 13.81 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 5.54 * (1 + (-0.311/100) * (-10 - 25)) = 6.14 V | OCPD = 1.56 * 8.85 = 13.81 A

Inputs from CEC Modules.csv for Jackery Inc JS-36A: Voc=5.54 V, beta_Voc=-0.311%/C, Isc=8.85 A, STC=36.0 W, Area=0.293 m2.

Result: 97 panels max on 600 V (595.6 V); 223 panels for 8 kW (703 sq ft).

What Are the Published CEC Specifications for Jackery Inc JS-36A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jackery Inc JS-36A.

Official California Energy Commission (NREL SAM) test parameters for Jackery Inc JS-36A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 36.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 32.7 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 5.54 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 4.53 V / 7.95 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.311 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.29% (0.293 m2) Array roof footprint density
Cell Count & Technology 8 cells (Mono-c-Si) Monofacial backsheet

How Many Jackery Inc JS-36A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jackery Inc JS-36A (36.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 167 6.01 kW 527 sq ft $1,504 $2,544
8 kW Class 223 8.03 kW 703 sq ft $2,010 $3,398
10 kW Class 278 10.01 kW 877 sq ft $2,505 $4,236

How Many Jackery Inc JS-36A Modules Fit in a Cold-Weather String?

Maximum series module counts for Jackery Inc JS-36A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=5.54V and beta_Voc=-0.311%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 6.32 V 94 panels 594.1 V 158 panels
-10 C (14 F) 6.14 V 97 panels 595.6 V 162 panels
0 C (32 F) 5.97 V 100 panels 597.0 V 167 panels
25 C (77 F STC) 5.54 V 108 panels 598.3 V 180 panels

Which Cross-Brand Solar Modules Compare Closest to Jackery Inc JS-36A?

Alternative CEC solar modules from competing brands near Jackery Inc JS-36A (36.0 W), including Tesla Inc SR25S3. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Tesla Inc SR25S3
Tesla Inc
25.0 W -11.0 W 4.3 V 10.58% 89.2%
Tesla Inc SR25T3
Tesla Inc
25.0 W -11.0 W 4.3 V 10.56% 87.6%
Solar Frame Solutions Inc SFS50S
Solar Frame Solutions Inc
50.0 W +14.0 W 6.1 V 13.89% 91.4%
Rare Manufacturing IW-40-B12345YZZ
Rare Manufacturing
40.0 W +4.0 W 9.26 V 11.74% 64.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jackery Inc JS-36A?

Evaluate Jackery Inc JS-36A (36.0 W STC, 5.54 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jackery Inc JS-36A reaches 6.32 V per panel—exceeding 94 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 223 panels for an 8 kW build require 703 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 223 panels (703 sq ft).
  • 2026 tax credit baseline: cash residential installs of Jackery Inc JS-36A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jackery Inc JS-36A 8 kW Residential Fit

Needs 223 modules (703 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 97 panels (-10 C) or 94 panels (-20 C), or compare Tesla Inc SR25S3.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 32.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jackery Inc JS-36A by Jackery Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Jackery Inc JS-36A?

Multiplying Jackery Inc JS-36A's 8.85 A short-circuit current by 1.56 equals 13.81 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Jackery Inc JS-36A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 6.14 V cold Voc at 14 F and handles 8.85 A Isc; string inverters cap Jackery Inc JS-36A at 97 panels on 600 V.

Is Jackery Inc JS-36A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jackery Inc JS-36A rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.