Rare Manufacturing IW-40-B12345YZZ is a 40.0 W STC (25.7 W PTC) Mono-c-Si solar module ranking #21,670 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 11.74% efficiency, 9.26 V Voc at 25 C, and 11.2 V cold Voc at -10 C (53 panels max per 600 V string).
- STC Wattage
- 40.0 W
- PTC Wattage
- 25.7 W
- Voc @ 25C
- 9.26 V
- Efficiency
- 11.74%
How Does Rare Manufacturing IW-40-B12345YZZ Compare Against Peer CEC Listings?
Engineering position of Rare Manufacturing IW-40-B12345YZZ (40.0 W STC) vs. GAF Energy LLC 294000328 across 5,889 CEC Mono-c-Si solar modules.
Built with 16 Mono-c-Si cells, Rare Manufacturing IW-40-B12345YZZ pairs typical 64.2% PTC-to-STC thermal output (25.7 W real-world rating) with 9.26 V nominal Voc. An 8 kW residential build (8,000 W DC, 5,140 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer GAF Energy LLC 294000328 offers a 45.0 W alternative.
Where Does Rare Manufacturing IW-40-B12345YZZ Fall Across Listed CEC Models?
Plots Rare Manufacturing IW-40-B12345YZZ at 40.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Rare Manufacturing IW-40-B12345YZZ?
Benchmarks Rare Manufacturing IW-40-B12345YZZ on STC wattage, thermal PTC/STC retention, and 11.74 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Rare Manufacturing IW-40-B12345YZZ?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Rare Manufacturing IW-40-B12345YZZ by Rare Manufacturing.
40.0 W STC · Higher Than 0.0%
40.0 W STC (-345.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
11.74% Aperture Efficiency
Power density 117.3 W/m2 (8.17 percentage points below 19.91% CEC median). PTC/STC ratio: 64.2% (rank #21,677).
53 Panels Max @ -10 C (600 V)
Cold Voc reaches 11.2 V at -10 C (593.6 V string) and 11.76 V at -20 C (51 max).
200 Panels = 8,000 W STC
Occupies 68.2 m2 (734 sq ft) producing 5,140 W PTC; NEC 690.8 OCPD floor is 8.64 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 9.26 * (1 + (-0.599/100) * (-10 - 25)) = 11.2 V | OCPD = 1.56 * 5.54 = 8.64 A
Inputs from CEC Modules.csv for Rare Manufacturing IW-40-B12345YZZ: Voc=9.26 V, beta_Voc=-0.599%/C, Isc=5.54 A, STC=40.0 W, Area=0.341 m2.
Result: 53 panels max on 600 V (593.6 V); 200 panels for 8 kW (734 sq ft).
What Are the Published CEC Specifications for Rare Manufacturing IW-40-B12345YZZ?
Laboratory test ratings recorded for Rare Manufacturing IW-40-B12345YZZ (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 40.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 25.7 W (64.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 9.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 8.0 V / 5.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.599 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 11.74% (0.341 m2) | Array roof footprint density |
| Cell Count & Technology | 16 cells (Mono-c-Si) | Monofacial backsheet |
How Many Rare Manufacturing IW-40-B12345YZZ Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (734 sq ft at 8 kW), and estimated Year-1 electric bill offset for Rare Manufacturing IW-40-B12345YZZ.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 150 | 6.0 kW | 551 sq ft | $1,502 | $2,539 |
| 8 kW Class | 200 | 8.0 kW | 734 sq ft | $2,002 | $3,386 |
| 10 kW Class | 250 | 10.0 kW | 918 sq ft | $2,503 | $4,232 |
How Many Rare Manufacturing IW-40-B12345YZZ Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Rare Manufacturing IW-40-B12345YZZ (beta_Voc -0.599%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 11.76 V | 51 panels | 599.8 V | 85 panels |
| -10 C (14 F) | 11.2 V | 53 panels | 593.6 V | 89 panels |
| 0 C (32 F) | 10.65 V | 56 panels | 596.4 V | 93 panels |
| 25 C (77 F STC) | 9.26 V | 64 panels | 592.6 V | 107 panels |
Which Cross-Brand Solar Modules Compare Closest to Rare Manufacturing IW-40-B12345YZZ?
Closest cross-brand CEC competitors to Rare Manufacturing IW-40-B12345YZZ matched near 40.0 W STC and 9.26 V Voc, led by GAF Energy LLC 294000328.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GAF Energy LLC 294000328 GAF Energy LLC |
45.0 W | +5.0 W | 10.89 V | 6.43% | 85.8% |
| GAF Energy LLC TLS-1 GAF Energy LLC |
46.0 W | +6.0 W | 10.9 V | 6.57% | 90.0% |
| GAF Energy LLC TLS-11 GAF Energy LLC |
46.0 W | +6.0 W | 10.9 V | 6.57% | 90.0% |
| GAF Energy LLC TLS-12 GAF Energy LLC |
47.0 W | +7.0 W | 10.9 V | 6.71% | 85.1% |
What Are the Design Limits and Best-Fit Uses for Rare Manufacturing IW-40-B12345YZZ?
Evaluate Rare Manufacturing IW-40-B12345YZZ (40.0 W STC, 9.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Rare Manufacturing IW-40-B12345YZZ reaches 11.76 V per panel—exceeding 51 panels in series voids 600 V inverter warranties.
- Footprint constraint: 200 panels for an 8 kW build require 734 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 200 panels (734 sq ft).
- 2026 tax credit baseline: cash residential installs of Rare Manufacturing IW-40-B12345YZZ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Rare Manufacturing IW-40-B12345YZZ 8 kW Residential Fit
Needs 200 modules (734 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 53 panels (-10 C) or 51 panels (-20 C), or compare GAF Energy LLC 294000328.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 25.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Rare Manufacturing IW-40-B12345YZZ by Rare Manufacturing grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Rare Manufacturing IW-40-B12345YZZ?
Multiplying Rare Manufacturing IW-40-B12345YZZ's 5.54 A short-circuit current by 1.56 equals 8.64 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Rare Manufacturing IW-40-B12345YZZ pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 11.2 V cold Voc at 14 F and handles 5.54 A Isc; string inverters cap Rare Manufacturing IW-40-B12345YZZ at 53 panels on 600 V.
Is Rare Manufacturing IW-40-B12345YZZ eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Rare Manufacturing IW-40-B12345YZZ rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)