GAF Energy LLC 294000328 is a 45.0 W STC (38.6 W PTC) Mono-c-Si solar module ranking #21,667 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 6.43% efficiency, 10.89 V Voc at 25 C, and 11.9 V cold Voc at -10 C (50 panels max per 600 V string).
- STC Wattage
- 45.0 W
- PTC Wattage
- 38.6 W
- Voc @ 25C
- 10.89 V
- Efficiency
- 6.43%
How Does GAF Energy LLC 294000328 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for GAF Energy LLC 294000328 (Mono-c-Si) residential solar systems.
GAF Energy LLC 294000328 delivers 64.3 W/m2 (13.48 percentage points below 19.91% CEC median) and typical 85.8% PTC-to-STC thermal output (38.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 178 panels (1,341 sq ft). At -4 F (-20 C), string voltage climbs to 12.18 V per unit, capping 600 V circuits at 49 panels. Compare specs directly with Rare Manufacturing IW-40-B12345YZZ (40.0 W).
Where Does GAF Energy LLC 294000328 Fall Across Listed CEC Models?
Comparison of GAF Energy LLC 294000328 (45.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define GAF Energy LLC 294000328?
Relative ranking of GAF Energy LLC 294000328 across nameplate watts, 85.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for GAF Energy LLC 294000328?
Summary of GAF Energy LLC 294000328 output rank, 8 kW array size (178 panels), efficiency rating, and 600 V string limit.
45.0 W STC · Higher Than 0.0%
45.0 W STC (-340.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
6.43% Aperture Efficiency
Power density 64.3 W/m2 (13.48 percentage points below 19.91% CEC median). PTC/STC ratio: 85.8% (rank #21,654).
50 Panels Max @ -10 C (600 V)
Cold Voc reaches 11.9 V at -10 C (595.0 V string) and 12.18 V at -20 C (49 max).
178 Panels = 8,010 W STC
Occupies 124.6 m2 (1,341 sq ft) producing 6,871 W PTC; NEC 690.8 OCPD floor is 8.02 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 10.89 * (1 + (-0.264/100) * (-10 - 25)) = 11.9 V | OCPD = 1.56 * 5.14 = 8.02 A
Inputs from CEC Modules.csv for GAF Energy LLC 294000328: Voc=10.89 V, beta_Voc=-0.264%/C, Isc=5.14 A, STC=45.0 W, Area=0.7 m2.
Result: 50 panels max on 600 V (595.0 V); 178 panels for 8 kW (1,341 sq ft).
What Are the Published CEC Specifications for GAF Energy LLC 294000328?
Complete CEC test sheet for GAF Energy LLC 294000328 including Isc (5.14 A), Voc (10.89 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 45.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 38.6 W (85.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 10.89 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 9.03 V / 4.89 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 6.43% (0.7 m2) | Array roof footprint density |
| Cell Count & Technology | 8 cells (Mono-c-Si) | Monofacial backsheet |
How Many GAF Energy LLC 294000328 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using GAF Energy LLC 294000328.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 134 | 6.03 kW | 1,010 sq ft | $1,509 | $2,552 |
| 8 kW Class | 178 | 8.01 kW | 1,341 sq ft | $2,005 | $3,390 |
| 10 kW Class | 223 | 10.04 kW | 1,680 sq ft | $2,513 | $4,249 |
How Many GAF Energy LLC 294000328 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for GAF Energy LLC 294000328 (10.89 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 12.18 V | 49 panels | 596.8 V | 82 panels |
| -10 C (14 F) | 11.9 V | 50 panels | 595.0 V | 84 panels |
| 0 C (32 F) | 11.61 V | 51 panels | 592.1 V | 86 panels |
| 25 C (77 F STC) | 10.89 V | 55 panels | 599.0 V | 91 panels |
Which Cross-Brand Solar Modules Compare Closest to GAF Energy LLC 294000328?
Four comparable CEC modules such as Rare Manufacturing IW-40-B12345YZZ (40.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Rare Manufacturing IW-40-B12345YZZ Rare Manufacturing |
40.0 W | -5.0 W | 9.26 V | 11.74% | 64.2% |
| Sunflare Co FLEX20-55W Sunflare Co |
55.0 W | +10.0 W | 12.0 V | 9.32% | 90.0% |
| Jackery Inc JS-45A Jackery Inc |
45.0 W | Tie (0 W) | 5.54 V | 15.36% | 92.4% |
| Sunflare Co FLEX20-60W Sunflare Co |
60.0 W | +15.0 W | 12.5 V | 10.17% | 90.2% |
What Are the Design Limits and Best-Fit Uses for GAF Energy LLC 294000328?
Evaluate GAF Energy LLC 294000328 (45.0 W STC, 10.89 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GAF Energy LLC 294000328 reaches 12.18 V per panel—exceeding 49 panels in series voids 600 V inverter warranties.
- Footprint constraint: 178 panels for an 8 kW build require 1,341 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 178 panels (1,341 sq ft).
- 2026 tax credit baseline: cash residential installs of GAF Energy LLC 294000328 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GAF Energy LLC 294000328 8 kW Residential Fit
Needs 178 modules (1,341 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 50 panels (-10 C) or 49 panels (-20 C), or compare Rare Manufacturing IW-40-B12345YZZ.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 38.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GAF Energy LLC 294000328 by GAF Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.
How many GAF Energy LLC 294000328 panels fit on a 600 V winter solar string?
At -10 C (14 F), GAF Energy LLC 294000328 cold Voc rises from 10.89 V to 11.9 V (beta_Voc -0.264%/C), capping a 600 V string at 50 panels (595.0 V).
How much roof area does an 8 kW array of GAF Energy LLC 294000328 need?
An 8 kW DC system uses 178 GAF Energy LLC 294000328 modules (8,010 W STC / 6,871 W PTC), covering roughly 1,341 sq ft and saving ~$2,005/yr at 18.54 c/kWh.
How does GAF Energy LLC 294000328 compare against Rare Manufacturing IW-40-B12345YZZ?
GAF Energy LLC 294000328 outputs 45.0 W STC (10.89 V Voc, rank #21,667 of 21,677), while Rare Manufacturing IW-40-B12345YZZ delivers 40.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)