Skip to main content
WireAndSun
Calculators
CEC PV Module

GAF Energy LLC TLS-2-58 — CEC Solar Module Specifications

Manufacturer: GAF Energy LLC Registry: CEC Verified Engineering Specification

GAF Energy LLC TLS-2-58 is a 58.0 W STC (49.9 W PTC) Mono-c-Si solar module ranking #21,654 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 8.29% efficiency, 11.04 V Voc at 25 C, and 12.14 V cold Voc at -10 C (49 panels max per 600 V string).

STC Wattage
58.0 W
PTC Wattage
49.9 W
Voc @ 25C
11.04 V
Efficiency
8.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GAF Energy LLC TLS-2-58 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for GAF Energy LLC TLS-2-58 (Mono-c-Si) residential solar systems.

GAF Energy LLC TLS-2-58 delivers 82.9 W/m2 (11.62 percentage points below 19.91% CEC median) and typical 86.0% PTC-to-STC thermal output (49.9 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 138 panels (1,040 sq ft). At -4 F (-20 C), string voltage climbs to 12.45 V per unit, capping 600 V circuits at 48 panels. Compare specs directly with Sunflare Co FLEX20-55W (55.0 W).

Where Does GAF Energy LLC TLS-2-58 Fall Across Listed CEC Models?

Comparison of GAF Energy LLC TLS-2-58 (58.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GAF Energy LLC TLS-2-58 (58.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGAF Energy LLC TLS: 58.0 W

What Dataset Percentiles Define GAF Energy LLC TLS-2-58?

Relative ranking of GAF Energy LLC TLS-2-58 across nameplate watts, 86.0% PTC thermal ratio, and module aperture efficiency.

GAF Energy LLC TLS-2-58 Engineering BenchmarksPercentile comparison of GAF Energy LLC TLS-2-58 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage58.0 WPTC/STC Retention86.0%Module Efficiency8.29%

What Do the Dataset Ranks Show for GAF Energy LLC TLS-2-58?

Summary of GAF Energy LLC TLS-2-58 output rank, 8 kW array size (138 panels), efficiency rating, and 600 V string limit.

Rank #21,654 / 21,677

58.0 W STC · Higher Than 0.1%

58.0 W STC (-327.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,647

8.29% Aperture Efficiency

Power density 82.9 W/m2 (11.62 percentage points below 19.91% CEC median). PTC/STC ratio: 86.0% (rank #21,644).

NEC 690.7 Limit

49 Panels Max @ -10 C (600 V)

Cold Voc reaches 12.14 V at -10 C (594.9 V string) and 12.45 V at -20 C (48 max).

8 kW Reference Array

138 Panels = 8,004 W STC

Occupies 96.6 m2 (1,040 sq ft) producing 6,886 W PTC; NEC 690.8 OCPD floor is 10.34 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 11.04 * (1 + (-0.284/100) * (-10 - 25)) = 12.14 V | OCPD = 1.56 * 6.63 = 10.34 A

Inputs from CEC Modules.csv for GAF Energy LLC TLS-2-58: Voc=11.04 V, beta_Voc=-0.284%/C, Isc=6.63 A, STC=58.0 W, Area=0.7 m2.

Result: 49 panels max on 600 V (594.9 V); 138 panels for 8 kW (1,040 sq ft).

What Are the Published CEC Specifications for GAF Energy LLC TLS-2-58?

Complete CEC test sheet for GAF Energy LLC TLS-2-58 including Isc (6.63 A), Voc (11.04 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for GAF Energy LLC TLS-2-58.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 58.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 49.9 W (86.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 11.04 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 9.2 V / 6.31 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.284 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 8.29% (0.7 m2) Array roof footprint density
Cell Count & Technology 8 cells (Mono-c-Si) Monofacial backsheet

How Many GAF Energy LLC TLS-2-58 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using GAF Energy LLC TLS-2-58.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 104 6.03 kW 784 sq ft $1,509 $2,552
8 kW Class 138 8.0 kW 1,040 sq ft $2,002 $3,386
10 kW Class 173 10.03 kW 1,304 sq ft $2,510 $4,245

How Many GAF Energy LLC TLS-2-58 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for GAF Energy LLC TLS-2-58 (11.04 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=11.04V and beta_Voc=-0.284%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 12.45 V 48 panels 597.6 V 80 panels
-10 C (14 F) 12.14 V 49 panels 594.9 V 82 panels
0 C (32 F) 11.82 V 50 panels 591.0 V 84 panels
25 C (77 F STC) 11.04 V 54 panels 596.2 V 90 panels

Which Cross-Brand Solar Modules Compare Closest to GAF Energy LLC TLS-2-58?

Four comparable CEC modules such as Sunflare Co FLEX20-55W (55.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Sunflare Co FLEX20-55W
Sunflare Co
55.0 W -3.0 W 12.0 V 9.32% 90.0%
Sunflare Co FLEX20-60W
Sunflare Co
60.0 W +2.0 W 12.5 V 10.17% 90.2%
HALEE Inc HST-61-E-FP
HALEE Inc
61.0 W +3.0 W 9.5 V 14.88% 85.6%
Tesla Inc SR60T1
Tesla Inc
58.5 W +0.5 W 13.34 V 11.93% 89.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GAF Energy LLC TLS-2-58?

Evaluate GAF Energy LLC TLS-2-58 (58.0 W STC, 11.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GAF Energy LLC TLS-2-58 reaches 12.45 V per panel—exceeding 48 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 138 panels for an 8 kW build require 1,040 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 138 panels (1,040 sq ft).
  • 2026 tax credit baseline: cash residential installs of GAF Energy LLC TLS-2-58 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GAF Energy LLC TLS-2-58 8 kW Residential Fit

Needs 138 modules (1,040 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 49 panels (-10 C) or 48 panels (-20 C), or compare Sunflare Co FLEX20-55W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 49.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GAF Energy LLC TLS-2-58 by GAF Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

How many GAF Energy LLC TLS-2-58 panels fit on a 600 V winter solar string?

At -10 C (14 F), GAF Energy LLC TLS-2-58 cold Voc rises from 11.04 V to 12.14 V (beta_Voc -0.284%/C), capping a 600 V string at 49 panels (594.9 V).

How much roof area does an 8 kW array of GAF Energy LLC TLS-2-58 need?

An 8 kW DC system uses 138 GAF Energy LLC TLS-2-58 modules (8,004 W STC / 6,886 W PTC), covering roughly 1,040 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does GAF Energy LLC TLS-2-58 compare against Sunflare Co FLEX20-55W?

GAF Energy LLC TLS-2-58 outputs 58.0 W STC (11.04 V Voc, rank #21,654 of 21,677), while Sunflare Co FLEX20-55W delivers 55.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.