GAF Energy LLC TLS-2-58 is a 58.0 W STC (49.9 W PTC) Mono-c-Si solar module ranking #21,654 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 8.29% efficiency, 11.04 V Voc at 25 C, and 12.14 V cold Voc at -10 C (49 panels max per 600 V string).
- STC Wattage
- 58.0 W
- PTC Wattage
- 49.9 W
- Voc @ 25C
- 11.04 V
- Efficiency
- 8.29%
How Does GAF Energy LLC TLS-2-58 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for GAF Energy LLC TLS-2-58 (Mono-c-Si) residential solar systems.
GAF Energy LLC TLS-2-58 delivers 82.9 W/m2 (11.62 percentage points below 19.91% CEC median) and typical 86.0% PTC-to-STC thermal output (49.9 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 138 panels (1,040 sq ft). At -4 F (-20 C), string voltage climbs to 12.45 V per unit, capping 600 V circuits at 48 panels. Compare specs directly with Sunflare Co FLEX20-55W (55.0 W).
Where Does GAF Energy LLC TLS-2-58 Fall Across Listed CEC Models?
Comparison of GAF Energy LLC TLS-2-58 (58.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define GAF Energy LLC TLS-2-58?
Relative ranking of GAF Energy LLC TLS-2-58 across nameplate watts, 86.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for GAF Energy LLC TLS-2-58?
Summary of GAF Energy LLC TLS-2-58 output rank, 8 kW array size (138 panels), efficiency rating, and 600 V string limit.
58.0 W STC · Higher Than 0.1%
58.0 W STC (-327.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
8.29% Aperture Efficiency
Power density 82.9 W/m2 (11.62 percentage points below 19.91% CEC median). PTC/STC ratio: 86.0% (rank #21,644).
49 Panels Max @ -10 C (600 V)
Cold Voc reaches 12.14 V at -10 C (594.9 V string) and 12.45 V at -20 C (48 max).
138 Panels = 8,004 W STC
Occupies 96.6 m2 (1,040 sq ft) producing 6,886 W PTC; NEC 690.8 OCPD floor is 10.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 11.04 * (1 + (-0.284/100) * (-10 - 25)) = 12.14 V | OCPD = 1.56 * 6.63 = 10.34 A
Inputs from CEC Modules.csv for GAF Energy LLC TLS-2-58: Voc=11.04 V, beta_Voc=-0.284%/C, Isc=6.63 A, STC=58.0 W, Area=0.7 m2.
Result: 49 panels max on 600 V (594.9 V); 138 panels for 8 kW (1,040 sq ft).
What Are the Published CEC Specifications for GAF Energy LLC TLS-2-58?
Complete CEC test sheet for GAF Energy LLC TLS-2-58 including Isc (6.63 A), Voc (11.04 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 58.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 49.9 W (86.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 11.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 9.2 V / 6.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.284 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 8.29% (0.7 m2) | Array roof footprint density |
| Cell Count & Technology | 8 cells (Mono-c-Si) | Monofacial backsheet |
How Many GAF Energy LLC TLS-2-58 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using GAF Energy LLC TLS-2-58.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 104 | 6.03 kW | 784 sq ft | $1,509 | $2,552 |
| 8 kW Class | 138 | 8.0 kW | 1,040 sq ft | $2,002 | $3,386 |
| 10 kW Class | 173 | 10.03 kW | 1,304 sq ft | $2,510 | $4,245 |
How Many GAF Energy LLC TLS-2-58 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for GAF Energy LLC TLS-2-58 (11.04 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 12.45 V | 48 panels | 597.6 V | 80 panels |
| -10 C (14 F) | 12.14 V | 49 panels | 594.9 V | 82 panels |
| 0 C (32 F) | 11.82 V | 50 panels | 591.0 V | 84 panels |
| 25 C (77 F STC) | 11.04 V | 54 panels | 596.2 V | 90 panels |
Which Cross-Brand Solar Modules Compare Closest to GAF Energy LLC TLS-2-58?
Four comparable CEC modules such as Sunflare Co FLEX20-55W (55.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Sunflare Co FLEX20-55W Sunflare Co |
55.0 W | -3.0 W | 12.0 V | 9.32% | 90.0% |
| Sunflare Co FLEX20-60W Sunflare Co |
60.0 W | +2.0 W | 12.5 V | 10.17% | 90.2% |
| HALEE Inc HST-61-E-FP HALEE Inc |
61.0 W | +3.0 W | 9.5 V | 14.88% | 85.6% |
| Tesla Inc SR60T1 Tesla Inc |
58.5 W | +0.5 W | 13.34 V | 11.93% | 89.1% |
What Are the Design Limits and Best-Fit Uses for GAF Energy LLC TLS-2-58?
Evaluate GAF Energy LLC TLS-2-58 (58.0 W STC, 11.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GAF Energy LLC TLS-2-58 reaches 12.45 V per panel—exceeding 48 panels in series voids 600 V inverter warranties.
- Footprint constraint: 138 panels for an 8 kW build require 1,040 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 138 panels (1,040 sq ft).
- 2026 tax credit baseline: cash residential installs of GAF Energy LLC TLS-2-58 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GAF Energy LLC TLS-2-58 8 kW Residential Fit
Needs 138 modules (1,040 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 49 panels (-10 C) or 48 panels (-20 C), or compare Sunflare Co FLEX20-55W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 49.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GAF Energy LLC TLS-2-58 by GAF Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.
How many GAF Energy LLC TLS-2-58 panels fit on a 600 V winter solar string?
At -10 C (14 F), GAF Energy LLC TLS-2-58 cold Voc rises from 11.04 V to 12.14 V (beta_Voc -0.284%/C), capping a 600 V string at 49 panels (594.9 V).
How much roof area does an 8 kW array of GAF Energy LLC TLS-2-58 need?
An 8 kW DC system uses 138 GAF Energy LLC TLS-2-58 modules (8,004 W STC / 6,886 W PTC), covering roughly 1,040 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does GAF Energy LLC TLS-2-58 compare against Sunflare Co FLEX20-55W?
GAF Energy LLC TLS-2-58 outputs 58.0 W STC (11.04 V Voc, rank #21,654 of 21,677), while Sunflare Co FLEX20-55W delivers 55.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)