GAF Energy LLC TLS-2J-56 is a 56.0 W STC (48.1 W PTC) Mono-c-Si solar module ranking #21,658 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 8.0% efficiency, 10.66 V Voc at 25 C, and 11.72 V cold Voc at -10 C (51 panels max per 600 V string).
- STC Wattage
- 56.0 W
- PTC Wattage
- 48.1 W
- Voc @ 25C
- 10.66 V
- Efficiency
- 8.0%
How Does GAF Energy LLC TLS-2J-56 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for GAF Energy LLC TLS-2J-56 (Mono-c-Si) residential solar systems.
GAF Energy LLC TLS-2J-56 delivers 80.0 W/m2 (11.91 percentage points below 19.91% CEC median) and typical 85.9% PTC-to-STC thermal output (48.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 143 panels (1,077 sq ft). At -4 F (-20 C), string voltage climbs to 12.02 V per unit, capping 600 V circuits at 49 panels. Compare specs directly with Sunflare Co FLEX20-55W (55.0 W).
Where Does GAF Energy LLC TLS-2J-56 Fall Across Listed CEC Models?
Comparison of GAF Energy LLC TLS-2J-56 (56.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define GAF Energy LLC TLS-2J-56?
Relative ranking of GAF Energy LLC TLS-2J-56 across nameplate watts, 85.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for GAF Energy LLC TLS-2J-56?
Summary of GAF Energy LLC TLS-2J-56 output rank, 8 kW array size (143 panels), efficiency rating, and 600 V string limit.
56.0 W STC · Higher Than 0.1%
56.0 W STC (-329.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
8.0% Aperture Efficiency
Power density 80.0 W/m2 (11.91 percentage points below 19.91% CEC median). PTC/STC ratio: 85.9% (rank #21,652).
51 Panels Max @ -10 C (600 V)
Cold Voc reaches 11.72 V at -10 C (597.7 V string) and 12.02 V at -20 C (49 max).
143 Panels = 8,008 W STC
Occupies 100.1 m2 (1,077 sq ft) producing 6,878 W PTC; NEC 690.8 OCPD floor is 10.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 10.66 * (1 + (-0.284/100) * (-10 - 25)) = 11.72 V | OCPD = 1.56 * 6.63 = 10.34 A
Inputs from CEC Modules.csv for GAF Energy LLC TLS-2J-56: Voc=10.66 V, beta_Voc=-0.284%/C, Isc=6.63 A, STC=56.0 W, Area=0.7 m2.
Result: 51 panels max on 600 V (597.7 V); 143 panels for 8 kW (1,077 sq ft).
What Are the Published CEC Specifications for GAF Energy LLC TLS-2J-56?
Complete CEC test sheet for GAF Energy LLC TLS-2J-56 including Isc (6.63 A), Voc (10.66 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 56.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 48.1 W (85.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 10.66 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 8.9 V / 6.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.284 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 8.0% (0.7 m2) | Array roof footprint density |
| Cell Count & Technology | 8 cells (Mono-c-Si) | Monofacial backsheet |
How Many GAF Energy LLC TLS-2J-56 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using GAF Energy LLC TLS-2J-56.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 108 | 6.05 kW | 814 sq ft | $1,514 | $2,561 |
| 8 kW Class | 143 | 8.01 kW | 1,077 sq ft | $2,005 | $3,390 |
| 10 kW Class | 179 | 10.02 kW | 1,349 sq ft | $2,508 | $4,241 |
How Many GAF Energy LLC TLS-2J-56 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for GAF Energy LLC TLS-2J-56 (10.66 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 12.02 V | 49 panels | 589.0 V | 83 panels |
| -10 C (14 F) | 11.72 V | 51 panels | 597.7 V | 85 panels |
| 0 C (32 F) | 11.42 V | 52 panels | 593.8 V | 87 panels |
| 25 C (77 F STC) | 10.66 V | 56 panels | 597.0 V | 93 panels |
Which Cross-Brand Solar Modules Compare Closest to GAF Energy LLC TLS-2J-56?
Four comparable CEC modules such as Sunflare Co FLEX20-55W (55.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Sunflare Co FLEX20-55W Sunflare Co |
55.0 W | -1.0 W | 12.0 V | 9.32% | 90.0% |
| HALEE Inc HST-61-E-FP HALEE Inc |
61.0 W | +5.0 W | 9.5 V | 14.88% | 85.6% |
| Sunflare Co FLEX20-60W Sunflare Co |
60.0 W | +4.0 W | 12.5 V | 10.17% | 90.2% |
| Tesla Inc SR60T1 Tesla Inc |
58.5 W | +2.5 W | 13.34 V | 11.93% | 89.1% |
What Are the Design Limits and Best-Fit Uses for GAF Energy LLC TLS-2J-56?
Evaluate GAF Energy LLC TLS-2J-56 (56.0 W STC, 10.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GAF Energy LLC TLS-2J-56 reaches 12.02 V per panel—exceeding 49 panels in series voids 600 V inverter warranties.
- Footprint constraint: 143 panels for an 8 kW build require 1,077 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 143 panels (1,077 sq ft).
- 2026 tax credit baseline: cash residential installs of GAF Energy LLC TLS-2J-56 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GAF Energy LLC TLS-2J-56 8 kW Residential Fit
Needs 143 modules (1,077 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 51 panels (-10 C) or 49 panels (-20 C), or compare Sunflare Co FLEX20-55W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 48.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GAF Energy LLC TLS-2J-56 by GAF Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.
How many GAF Energy LLC TLS-2J-56 panels fit on a 600 V winter solar string?
At -10 C (14 F), GAF Energy LLC TLS-2J-56 cold Voc rises from 10.66 V to 11.72 V (beta_Voc -0.284%/C), capping a 600 V string at 51 panels (597.7 V).
How much roof area does an 8 kW array of GAF Energy LLC TLS-2J-56 need?
An 8 kW DC system uses 143 GAF Energy LLC TLS-2J-56 modules (8,008 W STC / 6,878 W PTC), covering roughly 1,077 sq ft and saving ~$2,005/yr at 18.54 c/kWh.
How does GAF Energy LLC TLS-2J-56 compare against Sunflare Co FLEX20-55W?
GAF Energy LLC TLS-2J-56 outputs 56.0 W STC (10.66 V Voc, rank #21,658 of 21,677), while Sunflare Co FLEX20-55W delivers 55.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)