Jackery Inc JS-45A is a 45.0 W STC (41.6 W PTC) Mono-c-Si solar module ranking #21,667 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 15.36% efficiency, 5.54 V Voc at 25 C, and 6.04 V cold Voc at -10 C (99 panels max per 600 V string).
- STC Wattage
- 45.0 W
- PTC Wattage
- 41.6 W
- Voc @ 25C
- 5.54 V
- Efficiency
- 15.36%
How Does Jackery Inc JS-45A Compare Against Peer CEC Listings?
How Jackery Inc Jackery Inc JS-45A handles rooftop heat (41.6 W PTC), 8 kW sizing, and cold winter string voltage.
Jackery Inc builds the Jackery Inc JS-45A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 153.6 W/m2 (4.55 percentage points below 19.91% CEC median). Compared against Solar Frame Solutions Inc SFS50S (50.0 W), this model holds strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Lower 5.54 V string voltage fits 99 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 16.16 A overcurrent floor served by a 20 A breaker.
Where Does Jackery Inc JS-45A Fall Across Listed CEC Models?
Where Jackery Inc JS-45A (45.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jackery Inc JS-45A?
Percentile placement of Jackery Inc JS-45A across power density (153.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jackery Inc JS-45A?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jackery Inc JS-45A specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
45.0 W STC · Higher Than 0.0%
45.0 W STC (-340.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.36% Aperture Efficiency
Power density 153.6 W/m2 (4.55 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
99 Panels Max @ -10 C (600 V)
Cold Voc reaches 6.04 V at -10 C (598.0 V string) and 6.19 V at -20 C (96 max).
178 Panels = 8,010 W STC
Occupies 52.2 m2 (561 sq ft) producing 7,405 W PTC; NEC 690.8 OCPD floor is 16.16 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 5.54 * (1 + (-0.26/100) * (-10 - 25)) = 6.04 V | OCPD = 1.56 * 10.36 = 16.16 A
Inputs from CEC Modules.csv for Jackery Inc JS-45A: Voc=5.54 V, beta_Voc=-0.26%/C, Isc=10.36 A, STC=45.0 W, Area=0.293 m2.
Result: 99 panels max on 600 V (598.0 V); 178 panels for 8 kW (561 sq ft).
What Are the Published CEC Specifications for Jackery Inc JS-45A?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jackery Inc JS-45A.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 45.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 41.6 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 5.54 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 4.53 V / 9.93 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.26 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.36% (0.293 m2) | Array roof footprint density |
| Cell Count & Technology | 8 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jackery Inc JS-45A Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jackery Inc JS-45A (45.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 134 | 6.03 kW | 423 sq ft | $1,509 | $2,552 |
| 8 kW Class | 178 | 8.01 kW | 561 sq ft | $2,005 | $3,390 |
| 10 kW Class | 223 | 10.04 kW | 703 sq ft | $2,513 | $4,249 |
How Many Jackery Inc JS-45A Modules Fit in a Cold-Weather String?
Maximum series module counts for Jackery Inc JS-45A from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 6.19 V | 96 panels | 594.2 V | 161 panels |
| -10 C (14 F) | 6.04 V | 99 panels | 598.0 V | 165 panels |
| 0 C (32 F) | 5.9 V | 101 panels | 595.9 V | 169 panels |
| 25 C (77 F STC) | 5.54 V | 108 panels | 598.3 V | 180 panels |
Which Cross-Brand Solar Modules Compare Closest to Jackery Inc JS-45A?
Alternative CEC solar modules from competing brands near Jackery Inc JS-45A (45.0 W), including Solar Frame Solutions Inc SFS50S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Solar Frame Solutions Inc SFS50S Solar Frame Solutions Inc |
50.0 W | +5.0 W | 6.1 V | 13.89% | 91.4% |
| Rare Manufacturing IW-40-B12345YZZ Rare Manufacturing |
40.0 W | -5.0 W | 9.26 V | 11.74% | 64.2% |
| GAF Energy LLC 294000328 GAF Energy LLC |
45.0 W | Tie (0 W) | 10.89 V | 6.43% | 85.8% |
| GAF Energy LLC TLS-1 GAF Energy LLC |
46.0 W | +1.0 W | 10.9 V | 6.57% | 90.0% |
What Are the Design Limits and Best-Fit Uses for Jackery Inc JS-45A?
Evaluate Jackery Inc JS-45A (45.0 W STC, 5.54 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jackery Inc JS-45A reaches 6.19 V per panel—exceeding 96 panels in series voids 600 V inverter warranties.
- Footprint constraint: 178 panels for an 8 kW build require 561 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 178 panels (561 sq ft).
- 2026 tax credit baseline: cash residential installs of Jackery Inc JS-45A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jackery Inc JS-45A 8 kW Residential Fit
Needs 178 modules (561 sq ft) with a 20 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 99 panels (-10 C) or 96 panels (-20 C), or compare Solar Frame Solutions Inc SFS50S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 41.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jackery Inc JS-45A by Jackery Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jackery Inc JS-45A?
Multiplying Jackery Inc JS-45A's 10.36 A short-circuit current by 1.56 equals 16.16 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Jackery Inc JS-45A pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 6.04 V cold Voc at 14 F and handles 10.36 A Isc; string inverters cap Jackery Inc JS-45A at 99 panels on 600 V.
Is Jackery Inc JS-45A eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jackery Inc JS-45A rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)