Tesla Inc SR73T3R is a 73.0 W STC (66.0 W PTC) Mono-c-Si solar module ranking #21,623 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 16.22% efficiency, 14.2 V Voc at 25 C, and 15.55 V cold Voc at -10 C (38 panels max per 600 V string).
- STC Wattage
- 73.0 W
- PTC Wattage
- 66.0 W
- Voc @ 25C
- 14.2 V
- Efficiency
- 16.22%
How Does Tesla Inc SR73T3R Compare Against Peer CEC Listings?
How Tesla Inc Tesla Inc SR73T3R handles rooftop heat (66.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Tesla Inc SR73T3R exhibits 6.6 A short-circuit current, requiring a 10.3 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,623 of 21,677 (337.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 49.5 m2 for an 8 kW system (137 panels for 10 kW). Lower 14.2 V string voltage fits 38 panels in series at 14 F and pairs easily with microinverters.
Where Does Tesla Inc SR73T3R Fall Across Listed CEC Models?
Where Tesla Inc SR73T3R (73.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Tesla Inc SR73T3R?
Percentile placement of Tesla Inc SR73T3R across power density (162.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Tesla Inc SR73T3R?
Four critical engineering numbers homeowners and solar installers check first when reviewing Tesla Inc SR73T3R specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
73.0 W STC · Higher Than 0.2%
73.0 W STC (-312.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.22% Aperture Efficiency
Power density 162.2 W/m2 (3.69 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
38 Panels Max @ -10 C (600 V)
Cold Voc reaches 15.55 V at -10 C (590.9 V string) and 15.93 V at -20 C (37 max).
110 Panels = 8,030 W STC
Occupies 49.5 m2 (533 sq ft) producing 7,260 W PTC; NEC 690.8 OCPD floor is 10.3 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 14.2 * (1 + (-0.271/100) * (-10 - 25)) = 15.55 V | OCPD = 1.56 * 6.6 = 10.3 A
Inputs from CEC Modules.csv for Tesla Inc SR73T3R: Voc=14.2 V, beta_Voc=-0.271%/C, Isc=6.6 A, STC=73.0 W, Area=0.45 m2.
Result: 38 panels max on 600 V (590.9 V); 110 panels for 8 kW (533 sq ft).
What Are the Published CEC Specifications for Tesla Inc SR73T3R?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Tesla Inc SR73T3R.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 73.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 66.0 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 14.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 11.6 V / 6.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.22% (0.45 m2) | Array roof footprint density |
| Cell Count & Technology | 21 cells (Mono-c-Si) | Monofacial backsheet |
How Many Tesla Inc SR73T3R Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Tesla Inc SR73T3R (73.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 83 | 6.06 kW | 402 sq ft | $1,517 | $2,565 |
| 8 kW Class | 110 | 8.03 kW | 533 sq ft | $2,010 | $3,398 |
| 10 kW Class | 137 | 10.0 kW | 664 sq ft | $2,503 | $4,232 |
How Many Tesla Inc SR73T3R Modules Fit in a Cold-Weather String?
Maximum series module counts for Tesla Inc SR73T3R from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 15.93 V | 37 panels | 589.4 V | 62 panels |
| -10 C (14 F) | 15.55 V | 38 panels | 590.9 V | 64 panels |
| 0 C (32 F) | 15.16 V | 39 panels | 591.2 V | 65 panels |
| 25 C (77 F STC) | 14.2 V | 42 panels | 596.4 V | 70 panels |
Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR73T3R?
Alternative CEC solar modules from competing brands near Tesla Inc SR73T3R (73.0 W), including SUNSTYLE AG / LTD SUNSTYLE M75.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| SUNSTYLE AG / LTD SUNSTYLE M75 SUNSTYLE AG / LTD |
75.0 W | +2.0 W | 15.6 V | 10.49% | 90.9% |
| SUNSTYLE AG / LTD SUNSTYLE M80 SUNSTYLE AG / LTD |
80.0 W | +7.0 W | 15.7 V | 11.19% | 91.0% |
| Midsummer AB SLIM 2 x 10 65 Midsummer AB |
65.0 W | -8.0 W | 12.6 V | 10.0% | 82.5% |
| Arka Energy Inc AEP-821-00012-A Arka Energy Inc |
77.0 W | +4.0 W | 11.56 V | 14.81% | 92.1% |
What Are the Design Limits and Best-Fit Uses for Tesla Inc SR73T3R?
Evaluate Tesla Inc SR73T3R (73.0 W STC, 14.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR73T3R reaches 15.93 V per panel—exceeding 37 panels in series voids 600 V inverter warranties.
- Footprint constraint: 110 panels for an 8 kW build require 533 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 110 panels (533 sq ft).
- 2026 tax credit baseline: cash residential installs of Tesla Inc SR73T3R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Tesla Inc SR73T3R 8 kW Residential Fit
Needs 110 modules (533 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 38 panels (-10 C) or 37 panels (-20 C), or compare SUNSTYLE AG / LTD SUNSTYLE M75.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 66.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Tesla Inc SR73T3R by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Tesla Inc SR73T3R PTC wattage (66.0 W) lower than STC (73.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 66.0 W PTC (90.4% retention) across Tesla Inc SR73T3R's 0.45 m2 aperture.
Who should skip Tesla Inc SR73T3R on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 110 Tesla Inc SR73T3R panels (533 sq ft) leave unusable roof gaps vs. SUNSTYLE AG / LTD SUNSTYLE M75.
What is the 1,000 V commercial string limit for Tesla Inc SR73T3R?
On 1,000 V commercial inverters at -10 C (15.55 V cold Voc), Tesla Inc SR73T3R fits up to 64 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc SR73T3R.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)