Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SL435M is a 435.0 W STC (407.6 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.14% efficiency, 49.5 V Voc at 25 C, and 54.14 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
407.6 W
Voc @ 25C
49.5 V
Efficiency
20.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SL435M Compare Against Peer CEC Listings?

Solar engineering breakdown for PEIMAR SL435M: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Measured at 435.0 W STC and 407.6 W PTC, PEIMAR SL435M sits +50.0 W vs all-CEC median (top 33.5%; higher than 66.5% of peers) among 21,677 listed modules. Power density reaches 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). Higher 49.5 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer AXITEC AC-435MH/144V rates 435.0 W.

Where Does PEIMAR SL435M Fall Across Listed CEC Models?

Distribution marker showing PEIMAR SL435M (435.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SL435M (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SL435M: 435.0 W

What Dataset Percentiles Define PEIMAR SL435M?

Dataset percentiles tracking PEIMAR SL435M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

PEIMAR SL435M Engineering BenchmarksPercentile comparison of PEIMAR SL435M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention93.7%Module Efficiency20.14%

What Do the Dataset Ranks Show for PEIMAR SL435M?

Benchmark highlights for PEIMAR SL435M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,983

20.14% Aperture Efficiency

Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.14 V at -10 C (595.5 V string) and 55.47 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,744 W PTC; NEC 690.8 OCPD floor is 17.39 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.5 * (1 + (-0.268/100) * (-10 - 25)) = 54.14 V | OCPD = 1.56 * 11.15 = 17.39 A

Inputs from CEC Modules.csv for PEIMAR SL435M: Voc=49.5 V, beta_Voc=-0.268%/C, Isc=11.15 A, STC=435.0 W, Area=2.16 m2.

Result: 11 panels max on 600 V (595.5 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for PEIMAR SL435M?

Official CEC datasheet figures for PEIMAR SL435M (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SL435M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 407.6 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.3 V / 10.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.14% (2.16 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SL435M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PEIMAR SL435M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 326 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 442 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 535 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Consolidated PEIMAR wattage variants sharing the PEIMAR SL435M mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the PEIMAR SL435M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SL425M 425.0 W 398.0 W 49.2 V 40.9 V 19.68%
PEIMAR SL430M 430.0 W 402.8 W 49.36 V 41.1 V 19.91%
PEIMAR SL435M 435.0 W 407.6 W 49.5 V 41.3 V 20.14%
PEIMAR SL440M 440.0 W 412.4 W 49.68 V 41.5 V 20.37%
PEIMAR SL445M 445.0 W 417.3 W 49.88 V 41.7 V 20.6%

How Many PEIMAR SL435M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SL435M (54.14 V at 14 F). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Computed from Voc=49.5V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.47 V 10 panels 554.7 V 18 panels
-10 C (14 F) 54.14 V 11 panels 595.5 V 18 panels
0 C (32 F) 52.82 V 11 panels 581.0 V 18 panels
25 C (77 F STC) 49.5 V 12 panels 594.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SL435M?

Competing CEC solar panels closest to PEIMAR SL435M in nameplate wattage and Voc, starting with AXITEC AC-435MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
DualSun SAS DualSun 435M-144-01
DualSun SAS
435.0 W Tie (0 W) 49.4 V 20.14% 93.9%
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SL435M?

Evaluate PEIMAR SL435M (435.0 W STC, 49.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SL435M reaches 55.47 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SL435M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SL435M 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-435MH/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 407.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SL435M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

How many PEIMAR SL435M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SL435M cold Voc rises from 49.5 V to 54.14 V (beta_Voc -0.268%/C), capping a 600 V string at 11 panels (595.5 V).

How much roof area does an 8 kW array of PEIMAR SL435M need?

An 8 kW DC system uses 19 PEIMAR SL435M modules (8,265 W STC / 7,744 W PTC), covering roughly 442 sq ft and saving ~$2,070/yr at 18.54 c/kWh.

How does PEIMAR SL435M compare against AXITEC AC-435MH/144V?

PEIMAR SL435M outputs 435.0 W STC (49.5 V Voc, rank #6,850 of 21,677), while AXITEC AC-435MH/144V delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.