Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SL365M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SL365M is a 365.0 W STC (342.1 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.17% efficiency, 41.4 V Voc at 25 C, and 45.28 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
342.1 W
Voc @ 25C
41.4 V
Efficiency
20.17%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SL365M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SL365M handles rooftop heat (342.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SL365M exhibits 11.21 A short-circuit current, requiring a 17.49 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #12,044 of 21,677 (45.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 39.8 m2 for an 8 kW system (28 panels for 10 kW). Mid-range 41.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does PEIMAR SL365M Fall Across Listed CEC Models?

Where PEIMAR SL365M (365.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SL365M (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SL365M: 365.0 W

What Dataset Percentiles Define PEIMAR SL365M?

Percentile placement of PEIMAR SL365M across power density (201.7 W/m2), thermal retention, and nameplate STC wattage. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

PEIMAR SL365M Engineering BenchmarksPercentile comparison of PEIMAR SL365M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention93.7%Module Efficiency20.17%

What Do the Dataset Ranks Show for PEIMAR SL365M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SL365M specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,881

20.17% Aperture Efficiency

Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.28 V at -10 C (588.6 V string) and 46.39 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 17.49 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.4 * (1 + (-0.268/100) * (-10 - 25)) = 45.28 V | OCPD = 1.56 * 11.21 = 17.49 A

Inputs from CEC Modules.csv for PEIMAR SL365M: Voc=41.4 V, beta_Voc=-0.268%/C, Isc=11.21 A, STC=365.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (588.6 V); 22 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for PEIMAR SL365M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SL365M. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SL365M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 342.1 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.21 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.5 V / 10.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.17% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SL365M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SL365M (365.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 331 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 429 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 546 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SL365M architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the PEIMAR SL365M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SL355M 355.0 W 332.5 W 40.95 V 34.1 V 19.61%
PEIMAR SL360M 360.0 W 337.3 W 41.2 V 34.3 V 19.89%
PEIMAR SL365M 365.0 W 342.1 W 41.4 V 34.5 V 20.17%
PEIMAR SL370M 370.0 W 346.9 W 41.6 V 34.7 V 20.44%

How Many PEIMAR SL365M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SL365M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.4V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.39 V 12 panels 556.7 V 21 panels
-10 C (14 F) 45.28 V 13 panels 588.6 V 22 panels
0 C (32 F) 44.17 V 13 panels 574.2 V 22 panels
25 C (77 F STC) 41.4 V 14 panels 579.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SL365M?

Alternative CEC solar modules from competing brands near PEIMAR SL365M (365.0 W), including Caterpillar Inc PVC365MP03HA. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC365MP03HA
Caterpillar Inc
365.0 W Tie (0 W) 41.0 V 20.62% 93.5%
Bluesun Solar CoLtd BSM365M-60HPH
Bluesun Solar CoLtd
365.0 W Tie (0 W) 40.9 V 20.05% 92.8%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.51% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.17% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SL365M?

Evaluate PEIMAR SL365M (365.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SL365M reaches 46.39 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SL365M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SL365M 8 kW Residential Fit

Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Caterpillar Inc PVC365MP03HA.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 342.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SL365M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Why is PEIMAR SL365M PTC wattage (342.1 W) lower than STC (365.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 342.1 W PTC (93.7% retention) across PEIMAR SL365M's 1.81 m2 aperture.

Who should skip PEIMAR SL365M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 PEIMAR SL365M panels (429 sq ft) leave unusable roof gaps vs. Caterpillar Inc PVC365MP03HA.

What is the 1,000 V commercial string limit for PEIMAR SL365M?

On 1,000 V commercial inverters at -10 C (45.28 V cold Voc), PEIMAR SL365M fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SL365M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.