Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W is a 365.0 W STC (337.9 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.51% efficiency, 40.7 V Voc at 25 C, and 45.14 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 337.9 W
- Voc @ 25C
- 40.7 V
- Efficiency
- 20.51%
How Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Compare Against Peer CEC Listings?
Solar engineering breakdown for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 365.0 W STC and 337.9 W PTC, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W sits -20.0 W vs all-CEC median (below all-CEC median; higher than 42.9% of peers) among 21,677 listed modules. Power density reaches 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). Mid-range 40.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Aptos Solar Technology LLC DNA-120-MF26-365W rates 365.0 W.
Where Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Fall Across Listed CEC Models?
Distribution marker showing Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?
Dataset percentiles tracking Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?
Benchmark highlights for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.51% Aperture Efficiency
Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.14 V at -10 C (586.8 V string) and 46.41 V at -20 C (12 max).
22 Panels = 8,030 W STC
Occupies 39.2 m2 (422 sq ft) producing 7,434 W PTC; NEC 690.8 OCPD floor is 17.8 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.7 * (1 + (-0.312/100) * (-10 - 25)) = 45.14 V | OCPD = 1.56 * 11.41 = 17.8 A
Inputs from CEC Modules.csv for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W: Voc=40.7 V, beta_Voc=-0.312%/C, Isc=11.41 A, STC=365.0 W, Area=1.78 m2.
Result: 13 panels max on 600 V (586.8 V); 22 panels for 8 kW (422 sq ft).
What Are the Published CEC Specifications for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?
Official CEC datasheet figures for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 337.9 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.1 V / 10.71 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.51% (1.78 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 326 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 422 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 536 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Series?
Consolidated Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd wattage variants sharing the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-355W | 355.0 W | 328.4 W | 40.3 V | 33.7 V | 19.94% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-360W | 360.0 W | 333.1 W | 40.5 V | 33.9 V | 20.22% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W | 365.0 W | 337.9 W | 40.7 V | 34.1 V | 20.51% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-370W | 370.0 W | 342.6 W | 40.9 V | 34.3 V | 20.79% |
How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (45.14 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.41 V | 12 panels | 556.9 V | 21 panels |
| -10 C (14 F) | 45.14 V | 13 panels | 586.8 V | 22 panels |
| 0 C (32 F) | 43.87 V | 13 panels | 570.3 V | 22 panels |
| 25 C (77 F STC) | 40.7 V | 14 panels | 569.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?
Competing CEC solar panels closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-MF26-365W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-MF26-365W Aptos Solar Technology LLC |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
| CertainTeed CT365HC11-06 CertainTeed |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
| ELITE Solar ET-M660BH365WB ELITE Solar |
365.0 W | Tie (0 W) | 40.7 V | 20.28% | 93.8% |
| ELITE Solar ET-M660BH365WW ELITE Solar |
365.0 W | Tie (0 W) | 40.7 V | 20.28% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?
Evaluate Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W reaches 46.41 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 422 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (422 sq ft).
- 2026 tax credit baseline: cash residential installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W 8 kW Residential Fit
Needs 22 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF26-365W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W panels fit on a 600 V winter solar string?
At -10 C (14 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W cold Voc rises from 40.7 V to 45.14 V (beta_Voc -0.312%/C), capping a 600 V string at 13 panels (586.8 V).
How much roof area does an 8 kW array of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W need?
An 8 kW DC system uses 22 Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W modules (8,030 W STC / 7,434 W PTC), covering roughly 422 sq ft and saving ~$2,010/yr at 18.54 c/kWh.
How does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W compare against Aptos Solar Technology LLC DNA-120-MF26-365W?
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W outputs 365.0 W STC (40.7 V Voc, rank #12,044 of 21,677), while Aptos Solar Technology LLC DNA-120-MF26-365W delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)