Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W — CEC Solar Module Specifications

Manufacturer: Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Registry: CEC Verified Engineering Specification

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W is a 365.0 W STC (337.9 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.51% efficiency, 40.7 V Voc at 25 C, and 45.14 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
337.9 W
Voc @ 25C
40.7 V
Efficiency
20.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Compare Against Peer CEC Listings?

Solar engineering breakdown for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 365.0 W STC and 337.9 W PTC, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W sits -20.0 W vs all-CEC median (below all-CEC median; higher than 42.9% of peers) among 21,677 listed modules. Power density reaches 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). Mid-range 40.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Aptos Solar Technology LLC DNA-120-MF26-365W rates 365.0 W.

Where Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Fall Across Listed CEC Models?

Distribution marker showing Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAmerisolar-Worldwi: 365.0 W

What Dataset Percentiles Define Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?

Dataset percentiles tracking Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Engineering BenchmarksPercentile comparison of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention92.6%Module Efficiency20.51%

What Do the Dataset Ranks Show for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?

Benchmark highlights for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,487

20.51% Aperture Efficiency

Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.14 V at -10 C (586.8 V string) and 46.41 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,434 W PTC; NEC 690.8 OCPD floor is 17.8 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.7 * (1 + (-0.312/100) * (-10 - 25)) = 45.14 V | OCPD = 1.56 * 11.41 = 17.8 A

Inputs from CEC Modules.csv for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W: Voc=40.7 V, beta_Voc=-0.312%/C, Isc=11.41 A, STC=365.0 W, Area=1.78 m2.

Result: 13 panels max on 600 V (586.8 V); 22 panels for 8 kW (422 sq ft).

What Are the Published CEC Specifications for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?

Official CEC datasheet figures for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 337.9 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.1 V / 10.71 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.312 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.51% (1.78 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 326 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 422 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 536 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Series?

Consolidated Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd wattage variants sharing the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W mechanical and cell layout.

Sibling CEC listings grouped into the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-355W 355.0 W 328.4 W 40.3 V 33.7 V 19.94%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-360W 360.0 W 333.1 W 40.5 V 33.9 V 20.22%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W 365.0 W 337.9 W 40.7 V 34.1 V 20.51%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-370W 370.0 W 342.6 W 40.9 V 34.3 V 20.79%

How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (45.14 V at 14 F).

Computed from Voc=40.7V and beta_Voc=-0.312%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.41 V 12 panels 556.9 V 21 panels
-10 C (14 F) 45.14 V 13 panels 586.8 V 22 panels
0 C (32 F) 43.87 V 13 panels 570.3 V 22 panels
25 C (77 F STC) 40.7 V 14 panels 569.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?

Competing CEC solar panels closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-MF26-365W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-120-MF26-365W
Aptos Solar Technology LLC
365.0 W Tie (0 W) 40.7 V 20.74% 91.3%
CertainTeed CT365HC11-06
CertainTeed
365.0 W Tie (0 W) 40.7 V 20.74% 91.3%
ELITE Solar ET-M660BH365WB
ELITE Solar
365.0 W Tie (0 W) 40.7 V 20.28% 93.8%
ELITE Solar ET-M660BH365WW
ELITE Solar
365.0 W Tie (0 W) 40.7 V 20.28% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W?

Evaluate Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W reaches 46.41 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 422 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (422 sq ft).
  • 2026 tax credit baseline: cash residential installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W 8 kW Residential Fit

Needs 22 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF26-365W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W panels fit on a 600 V winter solar string?

At -10 C (14 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W cold Voc rises from 40.7 V to 45.14 V (beta_Voc -0.312%/C), capping a 600 V string at 13 panels (586.8 V).

How much roof area does an 8 kW array of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W need?

An 8 kW DC system uses 22 Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W modules (8,030 W STC / 7,434 W PTC), covering roughly 422 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W compare against Aptos Solar Technology LLC DNA-120-MF26-365W?

Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W outputs 365.0 W STC (40.7 V Voc, rank #12,044 of 21,677), while Aptos Solar Technology LLC DNA-120-MF26-365W delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.