Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W is a 365.0 W STC (337.0 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.17% efficiency, 40.7 V Voc at 25 C, and 44.67 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 337.0 W
- Voc @ 25C
- 40.7 V
- Efficiency
- 20.17%
How Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Compare Against Peer CEC Listings?
How Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W handles rooftop heat (337.0 W PTC), 8 kW sizing, and cold winter string voltage.
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd builds the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W (Mono-c-Si) as a compact residential or specialty off-grid module delivering 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-120-MF26-365W (365.0 W), this model holds strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Mid-range 40.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.83 A overcurrent floor served by a 20 A breaker.
Where Does Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Fall Across Listed CEC Models?
Where Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W (365.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W?
Percentile placement of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W across power density (201.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W?
Four critical engineering numbers homeowners and solar installers check first when reviewing Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W specifications.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.17% Aperture Efficiency
Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.67 V at -10 C (580.7 V string) and 45.81 V at -20 C (13 max).
22 Panels = 8,030 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,414 W PTC; NEC 690.8 OCPD floor is 17.83 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.7 * (1 + (-0.279/100) * (-10 - 25)) = 44.67 V | OCPD = 1.56 * 11.43 = 17.83 A
Inputs from CEC Modules.csv for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W: Voc=40.7 V, beta_Voc=-0.279%/C, Isc=11.43 A, STC=365.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (580.7 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 337.0 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.2 V / 10.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.17% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W (365.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 331 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 429 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 546 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd Series?
All closely matched Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd wattages and cosmetic trims sharing the Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-355W | 355.0 W | 327.5 W | 40.3 V | 33.8 V | 19.61% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-360W | 360.0 W | 332.2 W | 40.5 V | 34.0 V | 19.89% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W | 365.0 W | 337.0 W | 40.7 V | 34.2 V | 20.17% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-370W | 370.0 W | 341.7 W | 40.9 V | 34.4 V | 20.44% |
How Many Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Modules Fit in a Cold-Weather String?
Maximum series module counts for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.81 V | 13 panels | 595.5 V | 21 panels |
| -10 C (14 F) | 44.67 V | 13 panels | 580.7 V | 22 panels |
| 0 C (32 F) | 43.54 V | 13 panels | 566.0 V | 22 panels |
| 25 C (77 F STC) | 40.7 V | 14 panels | 569.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W?
Alternative CEC solar modules from competing brands near Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W (365.0 W), including Aptos Solar Technology LLC DNA-120-MF26-365W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-MF26-365W Aptos Solar Technology LLC |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
| CertainTeed CT365HC11-06 CertainTeed |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
| ELITE Solar ET-M660BH365WB ELITE Solar |
365.0 W | Tie (0 W) | 40.7 V | 20.28% | 93.8% |
| ELITE Solar ET-M660BH365WW ELITE Solar |
365.0 W | Tie (0 W) | 40.7 V | 20.28% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W?
Evaluate Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W (365.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W reaches 45.81 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF26-365W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W?
Multiplying Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W's 11.43 A short-circuit current by 1.56 equals 17.83 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.67 V cold Voc at 14 F and handles 11.43 A Isc; string inverters cap Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W at 13 panels on 600 V.
Is Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)