Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG330P is a 330.0 W STC (299.7 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.24 V Voc at 25 C, and 51.58 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
299.7 W
Voc @ 25C
46.24 V
Efficiency
17.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG330P Compare Against Peer CEC Listings?

Solar engineering breakdown for PEIMAR SG330P: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Measured at 330.0 W STC and 299.7 W PTC, PEIMAR SG330P sits -55.0 W vs all-CEC median (below all-CEC median; higher than 32.9% of peers) among 21,677 listed modules. Power density reaches 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). Mid-range 46.24 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/72330 rates 330.0 W.

Where Does PEIMAR SG330P Fall Across Listed CEC Models?

Distribution marker showing PEIMAR SG330P (330.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG330P (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG330P: 330.0 W

What Dataset Percentiles Define PEIMAR SG330P?

Dataset percentiles tracking PEIMAR SG330P power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

PEIMAR SG330P Engineering BenchmarksPercentile comparison of PEIMAR SG330P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.8%Module Efficiency17.01%

What Do the Dataset Ranks Show for PEIMAR SG330P?

Benchmark highlights for PEIMAR SG330P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,431

17.01% Aperture Efficiency

Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.58 V at -10 C (567.4 V string) and 53.11 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,492 W PTC; NEC 690.8 OCPD floor is 14.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.24 * (1 + (-0.33/100) * (-10 - 25)) = 51.58 V | OCPD = 1.56 * 9.32 = 14.54 A

Inputs from CEC Modules.csv for PEIMAR SG330P: Voc=46.24 V, beta_Voc=-0.33%/C, Isc=9.32 A, STC=330.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (567.4 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for PEIMAR SG330P?

Official CEC datasheet figures for PEIMAR SG330P (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG330P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 299.7 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.24 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.32 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.9 V / 8.71 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.01% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many PEIMAR SG330P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PEIMAR SG330P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 397 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 522 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 647 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Consolidated PEIMAR wattage variants sharing the PEIMAR SG330P mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the PEIMAR SG330P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG325P 325.0 W 295.0 W 45.99 V 37.7 V 16.75%
PEIMAR SG330P 330.0 W 299.7 W 46.24 V 37.9 V 17.01%

How Many PEIMAR SG330P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SG330P (51.58 V at 14 F). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Computed from Voc=46.24V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.11 V 11 panels 584.2 V 18 panels
-10 C (14 F) 51.58 V 11 panels 567.4 V 19 panels
0 C (32 F) 50.05 V 11 panels 550.5 V 19 panels
25 C (77 F STC) 46.24 V 12 panels 554.9 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG330P?

Competing CEC solar panels closest to PEIMAR SG330P in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/72330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.7%
Centrosolar America TM7 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
Centrosolar America TM7S 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG330P?

Evaluate PEIMAR SG330P (330.0 W STC, 46.24 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG330P reaches 53.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG330P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG330P 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG330P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

How many PEIMAR SG330P panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SG330P cold Voc rises from 46.24 V to 51.58 V (beta_Voc -0.33%/C), capping a 600 V string at 11 panels (567.4 V).

How much roof area does an 8 kW array of PEIMAR SG330P need?

An 8 kW DC system uses 25 PEIMAR SG330P modules (8,250 W STC / 7,492 W PTC), covering roughly 522 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does PEIMAR SG330P compare against GCL System Integration Technology Co Ltd GCL-M6/72330?

PEIMAR SG330P outputs 330.0 W STC (46.24 V Voc, rank #14,165 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/72330 delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.