Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG295P is a 295.0 W STC (263.7 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.2% efficiency, 43.3 V Voc at 25 C, and 48.77 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
263.7 W
Voc @ 25C
43.3 V
Efficiency
15.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG295P Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SG295P handles rooftop heat (263.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SG295P exhibits 9.15 A short-circuit current, requiring a 14.27 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #16,890 of 21,677 (16.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 54.3 m2 for an 8 kW system (34 panels for 10 kW). Mid-range 43.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does PEIMAR SG295P Fall Across Listed CEC Models?

Where PEIMAR SG295P (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG295P (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG295P: 295.0 W

What Dataset Percentiles Define PEIMAR SG295P?

Percentile placement of PEIMAR SG295P across power density (152.1 W/m2), thermal retention, and nameplate STC wattage. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

PEIMAR SG295P Engineering BenchmarksPercentile comparison of PEIMAR SG295P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention89.4%Module Efficiency15.2%

What Do the Dataset Ranks Show for PEIMAR SG295P?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SG295P specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,427

15.2% Aperture Efficiency

Power density 152.1 W/m2 (4.71 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.77 V at -10 C (585.2 V string) and 50.33 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,384 W PTC; NEC 690.8 OCPD floor is 14.27 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.3 * (1 + (-0.361/100) * (-10 - 25)) = 48.77 V | OCPD = 1.56 * 9.15 = 14.27 A

Inputs from CEC Modules.csv for PEIMAR SG295P: Voc=43.3 V, beta_Voc=-0.361%/C, Isc=9.15 A, STC=295.0 W, Area=1.94 m2.

Result: 12 panels max on 600 V (585.2 V); 28 panels for 8 kW (585 sq ft).

What Are the Published CEC Specifications for PEIMAR SG295P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SG295P. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG295P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 263.7 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.1 V / 8.17 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.361 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.2% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many PEIMAR SG295P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SG295P (295.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 439 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 585 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 710 sq ft $2,510 $4,245

How Many PEIMAR SG295P Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SG295P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.3V and beta_Voc=-0.361%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.33 V 11 panels 553.6 V 19 panels
-10 C (14 F) 48.77 V 12 panels 585.2 V 20 panels
0 C (32 F) 47.21 V 12 panels 566.5 V 21 panels
25 C (77 F STC) 43.3 V 13 panels 562.9 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG295P?

Alternative CEC solar modules from competing brands near PEIMAR SG295P (295.0 W), including Chinaland Solar Energy HSE295-72P. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chinaland Solar Energy HSE295-72P
Chinaland Solar Energy
295.0 W Tie (0 W) 43.3 V 15.28% 88.5%
Chinaland Solar Energy HSE295-72M
Chinaland Solar Energy
295.0 W Tie (0 W) 44.4 V 15.28% 90.2%
BYD Company Limited BYD295P6K-36
BYD Company Limited
295.0 W Tie (0 W) 44.9 V 15.21% 91.5%
Centrosolar America TP7 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG295P?

Evaluate PEIMAR SG295P (295.0 W STC, 43.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG295P reaches 50.33 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG295P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG295P 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Chinaland Solar Energy HSE295-72P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 263.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG295P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Why is PEIMAR SG295P PTC wattage (263.7 W) lower than STC (295.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 263.7 W PTC (89.4% retention) across PEIMAR SG295P's 1.94 m2 aperture.

Who should skip PEIMAR SG295P on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 PEIMAR SG295P panels (585 sq ft) leave unusable roof gaps vs. Chinaland Solar Energy HSE295-72P.

What is the 1,000 V commercial string limit for PEIMAR SG295P?

On 1,000 V commercial inverters at -10 C (48.77 V cold Voc), PEIMAR SG295P fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SG295P.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.