Chinaland Solar Energy HSE295-72P is a 295.0 W STC (261.0 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.28% efficiency, 43.3 V Voc at 25 C, and 48.83 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 261.0 W
- Voc @ 25C
- 43.3 V
- Efficiency
- 15.28%
How Does Chinaland Solar Energy HSE295-72P Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Chinaland Solar Energy HSE295-72P (Multi-c-Si) residential solar systems.
Homeowners evaluating Chinaland Solar Energy HSE295-72P need 21 panels for 6 kW or 28 panels (582 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (582 sq ft). Under NEC 690.7(A), beta_Voc (-0.365%/C) pushes open-circuit voltage to 48.83 V at 14 F and 50.41 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Chinaland Solar Energy HSE295-72P Fall Across Listed CEC Models?
Comparison of Chinaland Solar Energy HSE295-72P (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Chinaland Solar Energy HSE295-72P?
Relative ranking of Chinaland Solar Energy HSE295-72P across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Chinaland Solar Energy HSE295-72P?
Summary of Chinaland Solar Energy HSE295-72P output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.28% Aperture Efficiency
Power density 152.8 W/m2 (4.63 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.83 V at -10 C (586.0 V string) and 50.41 V at -20 C (11 max).
28 Panels = 8,260 W STC
Occupies 54.0 m2 (582 sq ft) producing 7,308 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.3 * (1 + (-0.365/100) * (-10 - 25)) = 48.83 V | OCPD = 1.56 * 8.64 = 13.48 A
Inputs from CEC Modules.csv for Chinaland Solar Energy HSE295-72P: Voc=43.3 V, beta_Voc=-0.365%/C, Isc=8.64 A, STC=295.0 W, Area=1.93 m2.
Result: 12 panels max on 600 V (586.0 V); 28 panels for 8 kW (582 sq ft).
What Are the Published CEC Specifications for Chinaland Solar Energy HSE295-72P?
Complete CEC test sheet for Chinaland Solar Energy HSE295-72P including Isc (8.64 A), Voc (43.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 261.0 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.5 V / 8.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.365 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.28% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Chinaland Solar Energy HSE295-72P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Chinaland Solar Energy HSE295-72P.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 436 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 582 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 706 sq ft | $2,510 | $4,245 |
Which Sibling Wattage & Trim Variants Belong to This Chinaland Solar Energy Series?
Related Chinaland Solar Energy power steps and black/silver trims consolidated into this Chinaland Solar Energy HSE295-72P series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE290-72P | 290.0 W | 256.4 W | 43.2 V | 36.3 V | 15.02% |
| Chinaland Solar Energy HSE295-72P | 295.0 W | 261.0 W | 43.3 V | 36.5 V | 15.28% |
How Many Chinaland Solar Energy HSE295-72P Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Chinaland Solar Energy HSE295-72P (43.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.41 V | 11 panels | 554.5 V | 19 panels |
| -10 C (14 F) | 48.83 V | 12 panels | 586.0 V | 20 panels |
| 0 C (32 F) | 47.25 V | 12 panels | 567.0 V | 21 panels |
| 25 C (77 F STC) | 43.3 V | 13 panels | 562.9 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Chinaland Solar Energy HSE295-72P?
Four comparable CEC modules such as BYD Company Limited BYD295P6K-36 (295.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD295P6K-36 BYD Company Limited |
295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| Centrosolar America TP7 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| Centrosolar America TP7S 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | -5.0 W | 44.4 V | 14.92% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Chinaland Solar Energy HSE295-72P?
Evaluate Chinaland Solar Energy HSE295-72P (295.0 W STC, 43.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chinaland Solar Energy HSE295-72P reaches 50.41 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 582 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (582 sq ft).
- 2026 tax credit baseline: cash residential installs of Chinaland Solar Energy HSE295-72P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chinaland Solar Energy HSE295-72P 8 kW Residential Fit
Needs 28 modules (582 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 261.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chinaland Solar Energy HSE295-72P by Chinaland Solar Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Chinaland Solar Energy HSE295-72P PTC wattage (261.0 W) lower than STC (295.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 261.0 W PTC (88.5% retention) across Chinaland Solar Energy HSE295-72P's 1.93 m2 aperture.
Who should skip Chinaland Solar Energy HSE295-72P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Chinaland Solar Energy HSE295-72P panels (582 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD295P6K-36.
What is the 1,000 V commercial string limit for Chinaland Solar Energy HSE295-72P?
On 1,000 V commercial inverters at -10 C (48.83 V cold Voc), Chinaland Solar Energy HSE295-72P fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Chinaland Solar Energy HSE295-72P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)