Chinaland Solar Energy HSE325-72M is a 325.0 W STC (293.9 W PTC) Mono-c-Si solar module ranking #14,546 of 21,677 CEC listings (below all-CEC median; higher than 31.1% of peers). It delivers 16.84% efficiency, 45.9 V Voc at 25 C, and 51.44 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 325.0 W
- PTC Wattage
- 293.9 W
- Voc @ 25C
- 45.9 V
- Efficiency
- 16.84%
How Does Chinaland Solar Energy HSE325-72M Compare Against Peer CEC Listings?
How Chinaland Solar Energy Chinaland Solar Energy HSE325-72M handles rooftop heat (293.9 W PTC), 8 kW sizing, and cold winter string voltage.
Chinaland Solar Energy builds the Chinaland Solar Energy HSE325-72M (Mono-c-Si) as a compact residential or specialty off-grid module delivering 168.4 W/m2 (3.07 percentage points below 19.91% CEC median). Compared against CertainTeed CT325P00-01 (325.0 W), this model holds typical 90.4% PTC-to-STC thermal output (293.9 W real-world rating). Mid-range 45.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.26 A overcurrent floor served by a 15 A breaker.
Where Does Chinaland Solar Energy HSE325-72M Fall Across Listed CEC Models?
Where Chinaland Solar Energy HSE325-72M (325.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Chinaland Solar Energy HSE325-72M?
Percentile placement of Chinaland Solar Energy HSE325-72M across power density (168.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Chinaland Solar Energy HSE325-72M?
Four critical engineering numbers homeowners and solar installers check first when reviewing Chinaland Solar Energy HSE325-72M specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
325.0 W STC · Higher Than 31.1%
325.0 W STC (-60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.84% Aperture Efficiency
Power density 168.4 W/m2 (3.07 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.44 V at -10 C (565.8 V string) and 53.03 V at -20 C (11 max).
25 Panels = 8,125 W STC
Occupies 48.2 m2 (519 sq ft) producing 7,348 W PTC; NEC 690.8 OCPD floor is 14.26 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.9 * (1 + (-0.345/100) * (-10 - 25)) = 51.44 V | OCPD = 1.56 * 9.14 = 14.26 A
Inputs from CEC Modules.csv for Chinaland Solar Energy HSE325-72M: Voc=45.9 V, beta_Voc=-0.345%/C, Isc=9.14 A, STC=325.0 W, Area=1.93 m2.
Result: 11 panels max on 600 V (565.8 V); 25 panels for 8 kW (519 sq ft).
What Are the Published CEC Specifications for Chinaland Solar Energy HSE325-72M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Chinaland Solar Energy HSE325-72M.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 325.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 293.9 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.9 V / 8.58 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.345 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.84% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Chinaland Solar Energy HSE325-72M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Chinaland Solar Energy HSE325-72M (325.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.17 kW | 395 sq ft | $1,544 | $2,611 |
| 8 kW Class | 25 | 8.12 kW | 519 sq ft | $2,032 | $3,437 |
| 10 kW Class | 31 | 10.07 kW | 644 sq ft | $2,520 | $4,262 |
How Many Chinaland Solar Energy HSE325-72M Modules Fit in a Cold-Weather String?
Maximum series module counts for Chinaland Solar Energy HSE325-72M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.03 V | 11 panels | 583.3 V | 18 panels |
| -10 C (14 F) | 51.44 V | 11 panels | 565.8 V | 19 panels |
| 0 C (32 F) | 49.86 V | 12 panels | 598.3 V | 20 panels |
| 25 C (77 F STC) | 45.9 V | 13 panels | 596.7 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Chinaland Solar Energy HSE325-72M?
Alternative CEC solar modules from competing brands near Chinaland Solar Energy HSE325-72M (325.0 W), including CertainTeed CT325P00-01. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT325P00-01 CertainTeed |
325.0 W | Tie (0 W) | 45.9 V | 17.96% | 91.8% |
| Flextronics FXS-325BB-MAB1W Flextronics |
325.0 W | Tie (0 W) | 45.8 V | 17.55% | 91.6% |
| Flextronics FXS-325BC-MAB1W Flextronics |
325.0 W | Tie (0 W) | 45.8 V | 17.55% | 91.6% |
| GCL System Integration Technology Co Ltd GCL-M6/72325 GCL System Integration Technology Co Ltd |
325.0 W | Tie (0 W) | 46.0 V | 16.75% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Chinaland Solar Energy HSE325-72M?
Evaluate Chinaland Solar Energy HSE325-72M (325.0 W STC, 45.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chinaland Solar Energy HSE325-72M reaches 53.03 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 519 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (519 sq ft).
- 2026 tax credit baseline: cash residential installs of Chinaland Solar Energy HSE325-72M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chinaland Solar Energy HSE325-72M 8 kW Residential Fit
Needs 25 modules (519 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT325P00-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 293.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chinaland Solar Energy HSE325-72M by Chinaland Solar Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Chinaland Solar Energy HSE325-72M?
Multiplying Chinaland Solar Energy HSE325-72M's 9.14 A short-circuit current by 1.56 equals 14.26 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Chinaland Solar Energy HSE325-72M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.44 V cold Voc at 14 F and handles 9.14 A Isc; string inverters cap Chinaland Solar Energy HSE325-72M at 11 panels on 600 V.
Is Chinaland Solar Energy HSE325-72M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Chinaland Solar Energy HSE325-72M rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)