Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV360K — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV360K is a 360.0 W STC (341.0 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 21.3% efficiency, 43.9 V Voc at 25 C, and 47.51 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
341.0 W
Voc @ 25C
43.9 V
Efficiency
21.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV360K Compare Against Peer CEC Listings?

Engineering position of PANASONIC CORPORATION OF NORTH AMERICA EVPV360K (360.0 W STC) vs. CSI Solar Co Ltd CS6XH-360M across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, PANASONIC CORPORATION OF NORTH AMERICA EVPV360K pairs strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677) with 43.9 V nominal Voc. An 8 kW residential build (8,280 W DC, 7,843 W PTC) saves ~$2,072/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS6XH-360M offers a 360.0 W alternative.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV360K Fall Across Listed CEC Models?

Plots PANASONIC CORPORATION OF NORTH AMERICA EVPV360K at 360.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV360K (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 360.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV360K?

Benchmarks PANASONIC CORPORATION OF NORTH AMERICA EVPV360K on STC wattage, thermal PTC/STC retention, and 21.3 aperture conversion efficiency against CEC peers.

PANASONIC CORPORATION OF NORTH AMERICA EVPV360K Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV360K wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention94.7%Module Efficiency21.3%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K by PANASONIC CORPORATION OF NORTH AMERICA.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,110

21.3% Aperture Efficiency

Power density 213.0 W/m2 (1.39 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.51 V at -10 C (570.1 V string) and 48.54 V at -20 C (12 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 38.9 m2 (418 sq ft) producing 7,843 W PTC; NEC 690.8 OCPD floor is 16.36 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.9 * (1 + (-0.235/100) * (-10 - 25)) = 47.51 V | OCPD = 1.56 * 10.49 = 16.36 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K: Voc=43.9 V, beta_Voc=-0.235%/C, Isc=10.49 A, STC=360.0 W, Area=1.69 m2.

Result: 12 panels max on 600 V (570.1 V); 23 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K?

Laboratory test ratings recorded for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 341.0 W (94.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.49 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.7 V / 9.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.3% (1.69 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV360K Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 309 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 418 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 509 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?

Sibling wattage bins and frame colors grouped with PANASONIC CORPORATION OF NORTH AMERICA EVPV360K under PANASONIC CORPORATION OF NORTH AMERICA to prevent duplicate spec pages.

Sibling CEC listings grouped into the PANASONIC CORPORATION OF NORTH AMERICA EVPV360K wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PANASONIC CORPORATION OF NORTH AMERICA EVPV350K 350.0 W 331.3 W 43.2 V 36.0 V 20.71%
PANASONIC CORPORATION OF NORTH AMERICA EVPV360K 360.0 W 341.0 W 43.9 V 36.7 V 21.3%
PANASONIC CORPORATION OF NORTH AMERICA EVPV370K 370.0 W 350.7 W 44.1 V 37.4 V 21.89%

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV360K Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K (beta_Voc -0.235%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=43.9V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.54 V 12 panels 582.5 V 20 panels
-10 C (14 F) 47.51 V 12 panels 570.1 V 21 panels
0 C (32 F) 46.48 V 12 panels 557.8 V 21 panels
25 C (77 F STC) 43.9 V 13 panels 570.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV360K?

Closest cross-brand CEC competitors to PANASONIC CORPORATION OF NORTH AMERICA EVPV360K matched near 360.0 W STC and 43.9 V Voc, led by CSI Solar Co Ltd CS6XH-360M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6XH-360M
CSI Solar Co Ltd
360.0 W Tie (0 W) 45.0 V 19.46% 92.8%
DualSun SAS DualSun 360M-120-00
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.3%
DualSun SAS DualSun 360M-120-01
DualSun SAS
360.0 W Tie (0 W) 40.9 V 19.89% 93.2%
CSI Solar Co Ltd CS3U-360MS
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.76% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV360K (360.0 W STC, 43.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV360K reaches 48.54 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 418 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (418 sq ft).
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV360K carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV360K 8 kW Residential Fit

Needs 23 modules (418 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-360M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 341.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PANASONIC CORPORATION OF NORTH AMERICA EVPV360K?

Multiplying PANASONIC CORPORATION OF NORTH AMERICA EVPV360K's 10.49 A short-circuit current by 1.56 equals 16.36 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can PANASONIC CORPORATION OF NORTH AMERICA EVPV360K pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.51 V cold Voc at 14 F and handles 10.49 A Isc; string inverters cap PANASONIC CORPORATION OF NORTH AMERICA EVPV360K at 12 panels on 600 V.

Is PANASONIC CORPORATION OF NORTH AMERICA EVPV360K eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV360K rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.