Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK is a 410.0 W STC (390.8 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 22.91% efficiency, 49.0 V Voc at 25 C, and 53.0 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
390.8 W
Voc @ 25C
49.0 V
Efficiency
22.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK Compare Against Peer CEC Listings?

Engineering position of PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK (410.0 W STC) vs. AXITEC AC-410MH/144V across 5,889 CEC Mono-c-Si solar modules.

Ranking #8,539 across 21,677 CEC solar panels (top 41.3%; higher than 58.7% of peers), PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK operates as a modern high-density residential and light-commercial module sitting equal to the 410.0 W Mono-c-Si median. Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 95.3% PTC-to-STC heat retention (#237 of 21,677), 20 panels occupy 385 sq ft and offset roughly $2,052/yr at average US rates (or $3,470/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK Fall Across Listed CEC Models?

Plots PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 410.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK?

Benchmarks PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK on STC wattage, thermal PTC/STC retention, and 22.91 aperture conversion efficiency against CEC peers.

PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention95.3%Module Efficiency22.91%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK by PANASONIC CORPORATION OF NORTH AMERICA.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,283

22.91% Aperture Efficiency

Power density 229.1 W/m2 (3.00 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.0 V at -10 C (583.0 V string) and 54.14 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 35.8 m2 (385 sq ft) producing 7,816 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.233/100) * (-10 - 25)) = 53.0 V | OCPD = 1.56 * 10.35 = 16.15 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK: Voc=49.0 V, beta_Voc=-0.233%/C, Isc=10.35 A, STC=410.0 W, Area=1.79 m2.

Result: 11 panels max on 600 V (583.0 V); 20 panels for 8 kW (385 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK?

Laboratory test ratings recorded for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 390.8 W (95.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.7 V / 9.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.233 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.91% (1.79 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (385 sq ft at 8 kW), and estimated Year-1 electric bill offset for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 289 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 385 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 482 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?

Sibling wattage bins and frame colors grouped with PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK under PANASONIC CORPORATION OF NORTH AMERICA to prevent duplicate spec pages.

Sibling CEC listings grouped into the PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PANASONIC CORPORATION OF NORTH AMERICA EVPV400HK 400.0 W 381.1 W 48.8 V 42.1 V 22.35%
PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK 410.0 W 390.8 W 49.0 V 42.7 V 22.91%

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK (beta_Voc -0.233%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.0V and beta_Voc=-0.233%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.14 V 11 panels 595.5 V 18 panels
-10 C (14 F) 53.0 V 11 panels 583.0 V 18 panels
0 C (32 F) 51.85 V 11 panels 570.4 V 19 panels
25 C (77 F STC) 49.0 V 12 panels 588.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK?

Closest cross-brand CEC competitors to PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK matched near 410.0 W STC and 49.0 V Voc, led by AXITEC AC-410MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-410MH/144V
AXITEC
410.0 W Tie (0 W) 48.91 V 20.71% 93.5%
BYD Company Limited BYD400MIK-36
BYD Company Limited
410.0 W Tie (0 W) 49.21 V 20.4% 94.0%
AXITEC AC-410MB/144V
AXITEC
410.0 W Tie (0 W) 49.3 V 21.03% 93.0%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK (410.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK reaches 54.14 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 385 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (385 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK 8 kW Residential Fit

Needs 20 modules (385 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-410MH/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 390.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK panels fit on a 600 V winter solar string?

At -10 C (14 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK cold Voc rises from 49.0 V to 53.0 V (beta_Voc -0.233%/C), capping a 600 V string at 11 panels (583.0 V).

How much roof area does an 8 kW array of PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK need?

An 8 kW DC system uses 20 PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK modules (8,200 W STC / 7,816 W PTC), covering roughly 385 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

How does PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK compare against AXITEC AC-410MH/144V?

PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK outputs 410.0 W STC (49.0 V Voc, rank #8,539 of 21,677), while AXITEC AC-410MH/144V delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.