Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 is a 430.0 W STC (413.1 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 22.87% efficiency, 49.0 V Voc at 25 C, and 53.03 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
430.0 W
PTC Wattage
413.1 W
Voc @ 25C
49.0 V
Efficiency
22.87%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 Compare Against Peer CEC Listings?

Engineering position of PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 (430.0 W STC) vs. AXITEC AC-435MB/144V across 5,889 CEC Mono-c-Si solar modules.

Built with 66 Mono-c-Si cells, PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 pairs strong 96.1% PTC-to-STC heat retention (#17 of 21,677) with 49.0 V nominal Voc. An 8 kW residential build (8,170 W DC, 7,849 W PTC) saves ~$2,045/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AXITEC AC-435MB/144V offers a 435.0 W alternative.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 Fall Across Listed CEC Models?

Plots PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 at 430.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 (430.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 430.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2?

Benchmarks PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 on STC wattage, thermal PTC/STC retention, and 22.87 aperture conversion efficiency against CEC peers.

PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage430.0 WPTC/STC Retention96.1%Module Efficiency22.87%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 by PANASONIC CORPORATION OF NORTH AMERICA.

Rank #7,266 / 21,677

Top 35.2% STC Output

430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,348

22.87% Aperture Efficiency

Power density 228.7 W/m2 (2.96 percentage points above 19.91% CEC median). PTC/STC ratio: 96.1% (rank #17).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.03 V at -10 C (583.3 V string) and 54.18 V at -20 C (11 max).

8 kW Reference Array

19 Panels = 8,170 W STC

Occupies 35.7 m2 (384 sq ft) producing 7,849 W PTC; NEC 690.8 OCPD floor is 16.86 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.235/100) * (-10 - 25)) = 53.03 V | OCPD = 1.56 * 10.81 = 16.86 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2: Voc=49.0 V, beta_Voc=-0.235%/C, Isc=10.81 A, STC=430.0 W, Area=1.88 m2.

Result: 11 panels max on 600 V (583.3 V); 19 panels for 8 kW (384 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2?

Laboratory test ratings recorded for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 430.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 413.1 W (96.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.81 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.8 V / 10.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.87% (1.88 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (384 sq ft at 8 kW), and estimated Year-1 electric bill offset for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.02 kW 283 sq ft $1,507 $2,548
8 kW Class 19 8.17 kW 384 sq ft $2,045 $3,458
10 kW Class 24 10.32 kW 486 sq ft $2,583 $4,368

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 (beta_Voc -0.235%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.0V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.18 V 11 panels 596.0 V 18 panels
-10 C (14 F) 53.03 V 11 panels 583.3 V 18 panels
0 C (32 F) 51.88 V 11 panels 570.7 V 19 panels
25 C (77 F STC) 49.0 V 12 panels 588.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2?

Closest cross-brand CEC competitors to PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 matched near 430.0 W STC and 49.0 V Voc, led by AXITEC AC-435MB/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-435MB/144V
AXITEC
435.0 W +5.0 W 49.1 V 20.33% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W +5.0 W 49.1 V 20.33% 92.6%
Caterpillar Inc PVC435MP03H
Caterpillar Inc
435.0 W +5.0 W 48.7 V 20.52% 93.6%
AXITEC AC-435MH/144V
AXITEC
435.0 W +5.0 W 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 (430.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 reaches 54.18 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 384 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (384 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 8 kW Residential Fit

Needs 19 modules (384 sq ft) with a 20 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-435MB/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 413.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2?

Multiplying PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2's 10.81 A short-circuit current by 1.56 equals 16.86 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.03 V cold Voc at 14 F and handles 10.81 A Isc; string inverters cap PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 at 11 panels on 600 V.

Is PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2 rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.