Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 is a 420.0 W STC (403.3 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 22.34% efficiency, 48.8 V Voc at 25 C, and 52.81 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
403.3 W
Voc @ 25C
48.8 V
Efficiency
22.34%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Compare Against Peer CEC Listings?

Solar engineering breakdown for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 420.0 W STC and 403.3 W PTC, PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 sits +35.0 W vs all-CEC median (top 37.8%; higher than 62.2% of peers) among 21,677 listed modules. Power density reaches 223.4 W/m2 (2.43 percentage points above 19.91% CEC median). Higher 48.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer DualSun SAS DualSun 420M-144-01 rates 420.0 W.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Fall Across Listed CEC Models?

Distribution marker showing PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (420.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 420.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?

Dataset percentiles tracking PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention96.0%Module Efficiency22.34%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?

Benchmark highlights for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,346

22.34% Aperture Efficiency

Power density 223.4 W/m2 (2.43 percentage points above 19.91% CEC median). PTC/STC ratio: 96.0% (rank #21).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.81 V at -10 C (580.9 V string) and 53.96 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 37.6 m2 (405 sq ft) producing 8,066 W PTC; NEC 690.8 OCPD floor is 16.75 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.8 * (1 + (-0.235/100) * (-10 - 25)) = 52.81 V | OCPD = 1.56 * 10.74 = 16.75 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2: Voc=48.8 V, beta_Voc=-0.235%/C, Isc=10.74 A, STC=420.0 W, Area=1.88 m2.

Result: 11 panels max on 600 V (580.9 V); 20 panels for 8 kW (405 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?

Official CEC datasheet figures for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 403.3 W (96.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.74 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.2 V / 9.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.34% (1.88 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 304 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 405 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 486 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?

Consolidated PANASONIC CORPORATION OF NORTH AMERICA wattage variants sharing the PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 mechanical and cell layout.

Sibling CEC listings grouped into the PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK2 410.0 W 393.5 W 48.6 V 41.6 V 21.81%
PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 420.0 W 403.3 W 48.8 V 42.2 V 22.34%

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (52.81 V at 14 F).

Computed from Voc=48.8V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.96 V 11 panels 593.6 V 18 panels
-10 C (14 F) 52.81 V 11 panels 580.9 V 18 panels
0 C (32 F) 51.67 V 11 panels 568.4 V 19 panels
25 C (77 F STC) 48.8 V 12 panels 585.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?

Competing CEC solar panels closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 in nameplate wattage and Voc, starting with DualSun SAS DualSun 420M-144-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 420M-144-01
DualSun SAS
420.0 W Tie (0 W) 48.8 V 19.44% 93.8%
AXITEC AC-410MH/144V
AXITEC
410.0 W -10.0 W 48.91 V 20.71% 93.5%
BYD Company Limited BYD400MIK-36
BYD Company Limited
410.0 W -10.0 W 49.21 V 20.4% 94.0%
AXITEC AC-410MB/144V
AXITEC
410.0 W -10.0 W 49.3 V 21.03% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (420.0 W STC, 48.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 reaches 53.96 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (405 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 8 kW Residential Fit

Needs 20 modules (405 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 403.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

How many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 panels fit on a 600 V winter solar string?

At -10 C (14 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 cold Voc rises from 48.8 V to 52.81 V (beta_Voc -0.235%/C), capping a 600 V string at 11 panels (580.9 V).

How much roof area does an 8 kW array of PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 need?

An 8 kW DC system uses 20 PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 modules (8,400 W STC / 8,066 W PTC), covering roughly 405 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

How does PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 compare against DualSun SAS DualSun 420M-144-01?

PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 outputs 420.0 W STC (48.8 V Voc, rank #7,910 of 21,677), while DualSun SAS DualSun 420M-144-01 delivers 420.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.