PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 is a 420.0 W STC (403.3 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 22.34% efficiency, 48.8 V Voc at 25 C, and 52.81 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 403.3 W
- Voc @ 25C
- 48.8 V
- Efficiency
- 22.34%
How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Compare Against Peer CEC Listings?
Solar engineering breakdown for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 420.0 W STC and 403.3 W PTC, PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 sits +35.0 W vs all-CEC median (top 37.8%; higher than 62.2% of peers) among 21,677 listed modules. Power density reaches 223.4 W/m2 (2.43 percentage points above 19.91% CEC median). Higher 48.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer DualSun SAS DualSun 420M-144-01 rates 420.0 W.
Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Fall Across Listed CEC Models?
Distribution marker showing PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (420.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?
Dataset percentiles tracking PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?
Benchmark highlights for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.34% Aperture Efficiency
Power density 223.4 W/m2 (2.43 percentage points above 19.91% CEC median). PTC/STC ratio: 96.0% (rank #21).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.81 V at -10 C (580.9 V string) and 53.96 V at -20 C (11 max).
20 Panels = 8,400 W STC
Occupies 37.6 m2 (405 sq ft) producing 8,066 W PTC; NEC 690.8 OCPD floor is 16.75 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.8 * (1 + (-0.235/100) * (-10 - 25)) = 52.81 V | OCPD = 1.56 * 10.74 = 16.75 A
Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2: Voc=48.8 V, beta_Voc=-0.235%/C, Isc=10.74 A, STC=420.0 W, Area=1.88 m2.
Result: 11 panels max on 600 V (580.9 V); 20 panels for 8 kW (405 sq ft).
What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?
Official CEC datasheet figures for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 403.3 W (96.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.2 V / 9.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.34% (1.88 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 304 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 405 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 486 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?
Consolidated PANASONIC CORPORATION OF NORTH AMERICA wattage variants sharing the PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK2 | 410.0 W | 393.5 W | 48.6 V | 41.6 V | 21.81% |
| PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 | 420.0 W | 403.3 W | 48.8 V | 42.2 V | 22.34% |
How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (52.81 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.96 V | 11 panels | 593.6 V | 18 panels |
| -10 C (14 F) | 52.81 V | 11 panels | 580.9 V | 18 panels |
| 0 C (32 F) | 51.67 V | 11 panels | 568.4 V | 19 panels |
| 25 C (77 F STC) | 48.8 V | 12 panels | 585.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?
Competing CEC solar panels closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 in nameplate wattage and Voc, starting with DualSun SAS DualSun 420M-144-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| AXITEC AC-410MH/144V AXITEC |
410.0 W | -10.0 W | 48.91 V | 20.71% | 93.5% |
| BYD Company Limited BYD400MIK-36 BYD Company Limited |
410.0 W | -10.0 W | 49.21 V | 20.4% | 94.0% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | -10.0 W | 49.3 V | 21.03% | 93.0% |
What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2?
Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 (420.0 W STC, 48.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 reaches 53.96 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (405 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 8 kW Residential Fit
Needs 20 modules (405 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 403.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.
How many PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 panels fit on a 600 V winter solar string?
At -10 C (14 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 cold Voc rises from 48.8 V to 52.81 V (beta_Voc -0.235%/C), capping a 600 V string at 11 panels (580.9 V).
How much roof area does an 8 kW array of PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 need?
An 8 kW DC system uses 20 PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 modules (8,400 W STC / 8,066 W PTC), covering roughly 405 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 compare against DualSun SAS DualSun 420M-144-01?
PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2 outputs 420.0 W STC (48.8 V Voc, rank #7,910 of 21,677), while DualSun SAS DualSun 420M-144-01 delivers 420.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)