Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV390H — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV390H is a 390.0 W STC (372.2 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 21.79% efficiency, 48.6 V Voc at 25 C, and 52.5 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
372.2 W
Voc @ 25C
48.6 V
Efficiency
21.79%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Compare Against Peer CEC Listings?

Engineering position of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (390.0 W STC) vs. CSI Solar Co Ltd CS3U-390MS across 5,889 CEC Mono-c-Si solar modules.

Built with 66 Mono-c-Si cells, PANASONIC CORPORATION OF NORTH AMERICA EVPV390H pairs strong 95.4% PTC-to-STC heat retention (#141 of 21,677) with 48.6 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,816 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3U-390MS offers a 390.0 W alternative.

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Fall Across Listed CEC Models?

Plots PANASONIC CORPORATION OF NORTH AMERICA EVPV390H at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 390.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Benchmarks PANASONIC CORPORATION OF NORTH AMERICA EVPV390H on STC wattage, thermal PTC/STC retention, and 21.79 aperture conversion efficiency against CEC peers.

PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention95.4%Module Efficiency21.79%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H by PANASONIC CORPORATION OF NORTH AMERICA.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,590

21.79% Aperture Efficiency

Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.5 V at -10 C (577.5 V string) and 53.61 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,816 W PTC; NEC 690.8 OCPD floor is 15.9 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.6 * (1 + (-0.229/100) * (-10 - 25)) = 52.5 V | OCPD = 1.56 * 10.19 = 15.9 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H: Voc=48.6 V, beta_Voc=-0.229%/C, Isc=10.19 A, STC=390.0 W, Area=1.79 m2.

Result: 11 panels max on 600 V (577.5 V); 21 panels for 8 kW (405 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Laboratory test ratings recorded for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 372.2 W (95.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.5 V / 9.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.79% (1.79 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 308 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 405 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 501 sq ft $2,538 $4,292

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV390H Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (beta_Voc -0.229%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.6V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.61 V 11 panels 589.7 V 18 panels
-10 C (14 F) 52.5 V 11 panels 577.5 V 19 panels
0 C (32 F) 51.38 V 11 panels 565.2 V 19 panels
25 C (77 F STC) 48.6 V 12 panels 583.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Closest cross-brand CEC competitors to PANASONIC CORPORATION OF NORTH AMERICA EVPV390H matched near 390.0 W STC and 48.6 V Voc, led by CSI Solar Co Ltd CS3U-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 48.2 V 20.31% 93.2%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W +5.0 W 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W +5.0 W 48.7 V 20.68% 92.5%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W -5.0 W 48.5 V 19.85% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV390H (390.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV390H reaches 53.61 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (405 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV390H 8 kW Residential Fit

Needs 21 modules (405 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PANASONIC CORPORATION OF NORTH AMERICA EVPV390H?

Multiplying PANASONIC CORPORATION OF NORTH AMERICA EVPV390H's 10.19 A short-circuit current by 1.56 equals 15.9 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can PANASONIC CORPORATION OF NORTH AMERICA EVPV390H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.5 V cold Voc at 14 F and handles 10.19 A Isc; string inverters cap PANASONIC CORPORATION OF NORTH AMERICA EVPV390H at 11 panels on 600 V.

Is PANASONIC CORPORATION OF NORTH AMERICA EVPV390H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV390H rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.