PANASONIC CORPORATION OF NORTH AMERICA EVPV410H is a 410.0 W STC (391.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 22.91% efficiency, 49.0 V Voc at 25 C, and 52.93 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 391.7 W
- Voc @ 25C
- 49.0 V
- Efficiency
- 22.91%
How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Compare Against Peer CEC Listings?
How PANASONIC CORPORATION OF NORTH AMERICA PANASONIC CORPORATION OF NORTH AMERICA EVPV410H handles rooftop heat (391.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, PANASONIC CORPORATION OF NORTH AMERICA EVPV410H exhibits 10.35 A short-circuit current, requiring a 16.15 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 35.8 m2 for an 8 kW system (25 panels for 10 kW). Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Fall Across Listed CEC Models?
Where PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?
Percentile placement of PANASONIC CORPORATION OF NORTH AMERICA EVPV410H across power density (229.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?
Four critical engineering numbers homeowners and solar installers check first when reviewing PANASONIC CORPORATION OF NORTH AMERICA EVPV410H specifications.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.91% Aperture Efficiency
Power density 229.1 W/m2 (3.00 percentage points above 19.91% CEC median). PTC/STC ratio: 95.5% (rank #102).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.93 V at -10 C (582.2 V string) and 54.05 V at -20 C (11 max).
20 Panels = 8,200 W STC
Occupies 35.8 m2 (385 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.0 * (1 + (-0.229/100) * (-10 - 25)) = 52.93 V | OCPD = 1.56 * 10.35 = 16.15 A
Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H: Voc=49.0 V, beta_Voc=-0.229%/C, Isc=10.35 A, STC=410.0 W, Area=1.79 m2.
Result: 11 panels max on 600 V (582.2 V); 20 panels for 8 kW (385 sq ft).
What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 391.7 W (95.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.7 V / 9.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.229 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.91% (1.79 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 289 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 385 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 482 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?
All closely matched PANASONIC CORPORATION OF NORTH AMERICA wattages and cosmetic trims sharing the PANASONIC CORPORATION OF NORTH AMERICA EVPV410H architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PANASONIC CORPORATION OF NORTH AMERICA EVPV400H | 400.0 W | 381.9 W | 48.8 V | 42.1 V | 22.35% |
| PANASONIC CORPORATION OF NORTH AMERICA EVPV410H | 410.0 W | 391.7 W | 49.0 V | 42.7 V | 22.91% |
How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Modules Fit in a Cold-Weather String?
Maximum series module counts for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.05 V | 11 panels | 594.5 V | 18 panels |
| -10 C (14 F) | 52.93 V | 11 panels | 582.2 V | 18 panels |
| 0 C (32 F) | 51.81 V | 11 panels | 569.9 V | 19 panels |
| 25 C (77 F STC) | 49.0 V | 12 panels | 588.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?
Alternative CEC solar modules from competing brands near PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W), including AXITEC AC-410MH/144V.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-410MH/144V AXITEC |
410.0 W | Tie (0 W) | 48.91 V | 20.71% | 93.5% |
| BYD Company Limited BYD400MIK-36 BYD Company Limited |
410.0 W | Tie (0 W) | 49.21 V | 20.4% | 94.0% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?
Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV410H reaches 54.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 385 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (385 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV410H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PANASONIC CORPORATION OF NORTH AMERICA EVPV410H 8 kW Residential Fit
Needs 20 modules (385 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-410MH/144V.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.
Why is PANASONIC CORPORATION OF NORTH AMERICA EVPV410H PTC wattage (391.7 W) lower than STC (410.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 391.7 W PTC (95.5% retention) across PANASONIC CORPORATION OF NORTH AMERICA EVPV410H's 1.79 m2 aperture.
Who should skip PANASONIC CORPORATION OF NORTH AMERICA EVPV410H on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 PANASONIC CORPORATION OF NORTH AMERICA EVPV410H panels (385 sq ft) leave unusable roof gaps vs. AXITEC AC-410MH/144V.
What is the 1,000 V commercial string limit for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?
On 1,000 V commercial inverters at -10 C (52.93 V cold Voc), PANASONIC CORPORATION OF NORTH AMERICA EVPV410H fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)