Skip to main content
WireAndSun
Calculators
CEC PV Module

PANASONIC CORPORATION OF NORTH AMERICA EVPV410H — CEC Solar Module Specifications

Manufacturer: PANASONIC CORPORATION OF NORTH AMERICA Registry: CEC Verified Engineering Specification

PANASONIC CORPORATION OF NORTH AMERICA EVPV410H is a 410.0 W STC (391.7 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 22.91% efficiency, 49.0 V Voc at 25 C, and 52.93 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
391.7 W
Voc @ 25C
49.0 V
Efficiency
22.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Compare Against Peer CEC Listings?

How PANASONIC CORPORATION OF NORTH AMERICA PANASONIC CORPORATION OF NORTH AMERICA EVPV410H handles rooftop heat (391.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PANASONIC CORPORATION OF NORTH AMERICA EVPV410H exhibits 10.35 A short-circuit current, requiring a 16.15 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 35.8 m2 for an 8 kW system (25 panels for 10 kW). Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Fall Across Listed CEC Models?

Where PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPANASONIC CORPORAT: 410.0 W

What Dataset Percentiles Define PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?

Percentile placement of PANASONIC CORPORATION OF NORTH AMERICA EVPV410H across power density (229.1 W/m2), thermal retention, and nameplate STC wattage.

PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Engineering BenchmarksPercentile comparison of PANASONIC CORPORATION OF NORTH AMERICA EVPV410H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention95.5%Module Efficiency22.91%

What Do the Dataset Ranks Show for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?

Four critical engineering numbers homeowners and solar installers check first when reviewing PANASONIC CORPORATION OF NORTH AMERICA EVPV410H specifications.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,283

22.91% Aperture Efficiency

Power density 229.1 W/m2 (3.00 percentage points above 19.91% CEC median). PTC/STC ratio: 95.5% (rank #102).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.93 V at -10 C (582.2 V string) and 54.05 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 35.8 m2 (385 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.229/100) * (-10 - 25)) = 52.93 V | OCPD = 1.56 * 10.35 = 16.15 A

Inputs from CEC Modules.csv for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H: Voc=49.0 V, beta_Voc=-0.229%/C, Isc=10.35 A, STC=410.0 W, Area=1.79 m2.

Result: 11 panels max on 600 V (582.2 V); 20 panels for 8 kW (385 sq ft).

What Are the Published CEC Specifications for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H.

Official California Energy Commission (NREL SAM) test parameters for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 391.7 W (95.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.7 V / 9.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.91% (1.79 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 289 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 385 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 482 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This PANASONIC CORPORATION OF NORTH AMERICA Series?

All closely matched PANASONIC CORPORATION OF NORTH AMERICA wattages and cosmetic trims sharing the PANASONIC CORPORATION OF NORTH AMERICA EVPV410H architecture.

Sibling CEC listings grouped into the PANASONIC CORPORATION OF NORTH AMERICA EVPV410H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PANASONIC CORPORATION OF NORTH AMERICA EVPV400H 400.0 W 381.9 W 48.8 V 42.1 V 22.35%
PANASONIC CORPORATION OF NORTH AMERICA EVPV410H 410.0 W 391.7 W 49.0 V 42.7 V 22.91%

How Many PANASONIC CORPORATION OF NORTH AMERICA EVPV410H Modules Fit in a Cold-Weather String?

Maximum series module counts for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.0V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.05 V 11 panels 594.5 V 18 panels
-10 C (14 F) 52.93 V 11 panels 582.2 V 18 panels
0 C (32 F) 51.81 V 11 panels 569.9 V 19 panels
25 C (77 F STC) 49.0 V 12 panels 588.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?

Alternative CEC solar modules from competing brands near PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W), including AXITEC AC-410MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-410MH/144V
AXITEC
410.0 W Tie (0 W) 48.91 V 20.71% 93.5%
BYD Company Limited BYD400MIK-36
BYD Company Limited
410.0 W Tie (0 W) 49.21 V 20.4% 94.0%
AXITEC AC-410MB/144V
AXITEC
410.0 W Tie (0 W) 49.3 V 21.03% 93.0%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?

Evaluate PANASONIC CORPORATION OF NORTH AMERICA EVPV410H (410.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PANASONIC CORPORATION OF NORTH AMERICA EVPV410H reaches 54.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 385 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (385 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PANASONIC CORPORATION OF NORTH AMERICA EVPV410H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PANASONIC CORPORATION OF NORTH AMERICA EVPV410H 8 kW Residential Fit

Needs 20 modules (385 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-410MH/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H by PANASONIC CORPORATION OF NORTH AMERICA grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PANASONIC CORPORATION OF NORTH AMERICA EVPV410H PTC wattage (391.7 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 391.7 W PTC (95.5% retention) across PANASONIC CORPORATION OF NORTH AMERICA EVPV410H's 1.79 m2 aperture.

Who should skip PANASONIC CORPORATION OF NORTH AMERICA EVPV410H on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 PANASONIC CORPORATION OF NORTH AMERICA EVPV410H panels (385 sq ft) leave unusable roof gaps vs. AXITEC AC-410MH/144V.

What is the 1,000 V commercial string limit for PANASONIC CORPORATION OF NORTH AMERICA EVPV410H?

On 1,000 V commercial inverters at -10 C (52.93 V cold Voc), PANASONIC CORPORATION OF NORTH AMERICA EVPV410H fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.