Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt PV-GRAF-60M6-300/M is a 300.0 W STC (273.4 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.29% efficiency, 39.6 V Voc at 25 C, and 43.79 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
273.4 W
Voc @ 25C
39.6 V
Efficiency
18.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt PV-GRAF-60M6-300/M Compare Against Peer CEC Listings?

Solar engineering breakdown for FreeVolt PV-GRAF-60M6-300/M: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt PV-GRAF-60M6-300/M stands 110.0 W below the 410.0 W Mono-c-Si median and typical 91.1% PTC-to-STC thermal output (273.4 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (34 panels) yields $1,502-$2,553/yr in baseline US bill offset. Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does FreeVolt PV-GRAF-60M6-300/M Fall Across Listed CEC Models?

Distribution marker showing FreeVolt PV-GRAF-60M6-300/M (300.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt PV-GRAF-60M6-300/M (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt PV-GRAF-6: 300.0 W

What Dataset Percentiles Define FreeVolt PV-GRAF-60M6-300/M?

Dataset percentiles tracking FreeVolt PV-GRAF-60M6-300/M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

FreeVolt PV-GRAF-60M6-300/M Engineering BenchmarksPercentile comparison of FreeVolt PV-GRAF-60M6-300/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention91.1%Module Efficiency18.29%

What Do the Dataset Ranks Show for FreeVolt PV-GRAF-60M6-300/M?

Benchmark highlights for FreeVolt PV-GRAF-60M6-300/M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,697

18.29% Aperture Efficiency

Power density 182.9 W/m2 (1.62 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.79 V at -10 C (569.3 V string) and 44.98 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 44.3 m2 (477 sq ft) producing 7,382 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.6 * (1 + (-0.302/100) * (-10 - 25)) = 43.79 V | OCPD = 1.56 * 9.7 = 15.13 A

Inputs from CEC Modules.csv for FreeVolt PV-GRAF-60M6-300/M: Voc=39.6 V, beta_Voc=-0.302%/C, Isc=9.7 A, STC=300.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (569.3 V); 27 panels for 8 kW (477 sq ft).

What Are the Published CEC Specifications for FreeVolt PV-GRAF-60M6-300/M?

Official CEC datasheet figures for FreeVolt PV-GRAF-60M6-300/M (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt PV-GRAF-60M6-300/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 273.4 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.0 V / 9.24 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.302 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.29% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt PV-GRAF-60M6-300/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many FreeVolt PV-GRAF-60M6-300/M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 353 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 477 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 600 sq ft $2,553 $4,317

How Many FreeVolt PV-GRAF-60M6-300/M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt PV-GRAF-60M6-300/M (43.79 V at 14 F).

Computed from Voc=39.6V and beta_Voc=-0.302%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.98 V 13 panels 584.7 V 22 panels
-10 C (14 F) 43.79 V 13 panels 569.3 V 22 panels
0 C (32 F) 42.59 V 14 panels 596.3 V 23 panels
25 C (77 F STC) 39.6 V 15 panels 594.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt PV-GRAF-60M6-300/M?

Competing CEC solar panels closest to FreeVolt PV-GRAF-60M6-300/M in nameplate wattage and Voc, starting with CertainTeed CT300M10-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT300M10-01
CertainTeed
300.0 W Tie (0 W) 39.1 V 18.33% 91.0%
CertainTeed CT300M11-01
CertainTeed
300.0 W Tie (0 W) 39.1 V 18.33% 90.1%
Enphase Energy Inc XACM-IQ7-LR6-60PB-300M
Enphase Energy Inc
300.0 W Tie (0 W) 40.1 V 18.99% 91.1%
CertainTeed CT300M10-03
CertainTeed
300.0 W Tie (0 W) 40.3 V 18.55% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt PV-GRAF-60M6-300/M?

Evaluate FreeVolt PV-GRAF-60M6-300/M (300.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt PV-GRAF-60M6-300/M reaches 44.98 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 477 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (477 sq ft).
  • 2026 tax credit baseline: cash residential installs of FreeVolt PV-GRAF-60M6-300/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt PV-GRAF-60M6-300/M 8 kW Residential Fit

Needs 27 modules (477 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT300M10-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 273.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt PV-GRAF-60M6-300/M by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for FreeVolt PV-GRAF-60M6-300/M?

Multiplying FreeVolt PV-GRAF-60M6-300/M's 9.7 A short-circuit current by 1.56 equals 15.13 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can FreeVolt PV-GRAF-60M6-300/M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.79 V cold Voc at 14 F and handles 9.7 A Isc; string inverters cap FreeVolt PV-GRAF-60M6-300/M at 13 panels on 600 V.

Is FreeVolt PV-GRAF-60M6-300/M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt PV-GRAF-60M6-300/M rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.