FreeVolt ECP-PVGRAF-HC-BF560-144MT-W is a 560.0 W STC (532.2 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.71% efficiency, 52.7 V Voc at 25 C, and 57.44 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 532.2 W
- Voc @ 25C
- 52.7 V
- Efficiency
- 21.71%
How Does FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (Mono-c-Si) residential solar systems. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Homeowners evaluating FreeVolt ECP-PVGRAF-HC-BF560-144MT-W need 11 panels for 6 kW or 15 panels (417 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.257%/C) pushes open-circuit voltage to 57.44 V at 14 F and 58.79 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Fall Across Listed CEC Models?
Comparison of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (560.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?
Relative ranking of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?
Summary of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.71% Aperture Efficiency
Power density 217.1 W/m2 (1.80 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.44 V at -10 C (574.4 V string) and 58.79 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,983 W PTC; NEC 690.8 OCPD floor is 20.03 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.7 * (1 + (-0.257/100) * (-10 - 25)) = 57.44 V | OCPD = 1.56 * 12.84 = 20.03 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W: Voc=52.7 V, beta_Voc=-0.257%/C, Isc=12.84 A, STC=560.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (574.4 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?
Complete CEC test sheet for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W including Isc (12.84 A), Voc (52.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 532.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 12.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.9 V / 12.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.71% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using FreeVolt ECP-PVGRAF-HC-BF560-144MT-W.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 305 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 417 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 500 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
Related FreeVolt power steps and black/silver trims consolidated into this FreeVolt ECP-PVGRAF-HC-BF560-144MT-W series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-HC-BF550-144MT-W | 550.0 W | 522.5 W | 52.5 V | 45.6 V | 21.32% |
| FreeVolt ECP-PVGRAF-HC-BF555-144MT-W | 555.0 W | 527.3 W | 52.6 V | 45.8 V | 21.51% |
| FreeVolt ECP-PVGRAF-HC-BF560-144MT-W | 560.0 W | 532.2 W | 52.7 V | 45.9 V | 21.71% |
| FreeVolt ECP-PVGRAF-HC-BF565-144MT-W | 565.0 W | 537.0 W | 52.9 V | 46.0 V | 21.9% |
| FreeVolt ECP-PVGRAF-HC-BF570-144MT-W | 570.0 W | 541.9 W | 53.0 V | 46.2 V | 22.09% |
How Many FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (52.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.79 V | 10 panels | 587.9 V | 17 panels |
| -10 C (14 F) | 57.44 V | 10 panels | 574.4 V | 17 panels |
| 0 C (32 F) | 56.09 V | 10 panels | 560.9 V | 17 panels |
| 25 C (77 F STC) | 52.7 V | 11 panels | 579.7 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?
Four comparable CEC modules such as Auxin Solar AXN10M560W (560.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M560W Auxin Solar |
560.0 W | Tie (0 W) | 52.48 V | 21.88% | 91.8% |
| Boviet Solar Technology Co Ltd BVM7612M-560-H-HC Boviet Solar Technology Co Ltd |
560.0 W | Tie (0 W) | 51.66 V | 21.71% | 95.0% |
| GermanSolar USA Inc GSM10-144-565W GermanSolar USA Inc |
565.0 W | +5.0 W | 53.34 V | 23.44% | 95.1% |
| Chint New Energy Technology Co Ltd CHSM72N-HC-560 Chint New Energy Technology Co Ltd |
560.0 W | Tie (0 W) | 50.55 V | 21.71% | 94.6% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?
Evaluate FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (560.0 W STC, 52.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-HC-BF560-144MT-W reaches 58.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-HC-BF560-144MT-W 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN10M560W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 532.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Why is FreeVolt ECP-PVGRAF-HC-BF560-144MT-W PTC wattage (532.2 W) lower than STC (560.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 532.2 W PTC (95.0% retention) across FreeVolt ECP-PVGRAF-HC-BF560-144MT-W's 2.58 m2 aperture.
Who should skip FreeVolt ECP-PVGRAF-HC-BF560-144MT-W on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 FreeVolt ECP-PVGRAF-HC-BF560-144MT-W panels (417 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M560W.
What is the 1,000 V commercial string limit for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?
On 1,000 V commercial inverters at -10 C (57.44 V cold Voc), FreeVolt ECP-PVGRAF-HC-BF560-144MT-W fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting FreeVolt ECP-PVGRAF-HC-BF560-144MT-W.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)