Skip to main content
WireAndSun
Calculators
CEC PV Module

FreeVolt ECP-PVGRAF-HC-BF560-144MT-W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-HC-BF560-144MT-W is a 560.0 W STC (532.2 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.71% efficiency, 52.7 V Voc at 25 C, and 57.44 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
560.0 W
PTC Wattage
532.2 W
Voc @ 25C
52.7 V
Efficiency
21.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (Mono-c-Si) residential solar systems. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Homeowners evaluating FreeVolt ECP-PVGRAF-HC-BF560-144MT-W need 11 panels for 6 kW or 15 panels (417 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.257%/C) pushes open-circuit voltage to 57.44 V at 14 F and 58.79 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Fall Across Listed CEC Models?

Comparison of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (560.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (560.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 560.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?

Relative ranking of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage560.0 WPTC/STC Retention95.0%Module Efficiency21.71%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?

Summary of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,404 / 21,677

Top 11.8% STC Output

560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,802

21.71% Aperture Efficiency

Power density 217.1 W/m2 (1.80 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.44 V at -10 C (574.4 V string) and 58.79 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,400 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,983 W PTC; NEC 690.8 OCPD floor is 20.03 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.7 * (1 + (-0.257/100) * (-10 - 25)) = 57.44 V | OCPD = 1.56 * 12.84 = 20.03 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W: Voc=52.7 V, beta_Voc=-0.257%/C, Isc=12.84 A, STC=560.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (574.4 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?

Complete CEC test sheet for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W including Isc (12.84 A), Voc (52.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 560.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 532.2 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.84 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.9 V / 12.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.257 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.71% (2.58 m2) Array roof footprint density
Cell Count & Technology 24 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using FreeVolt ECP-PVGRAF-HC-BF560-144MT-W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.16 kW 305 sq ft $1,542 $2,607
8 kW Class 15 8.4 kW 417 sq ft $2,102 $3,555
10 kW Class 18 10.08 kW 500 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

Related FreeVolt power steps and black/silver trims consolidated into this FreeVolt ECP-PVGRAF-HC-BF560-144MT-W series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-HC-BF560-144MT-W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-HC-BF550-144MT-W 550.0 W 522.5 W 52.5 V 45.6 V 21.32%
FreeVolt ECP-PVGRAF-HC-BF555-144MT-W 555.0 W 527.3 W 52.6 V 45.8 V 21.51%
FreeVolt ECP-PVGRAF-HC-BF560-144MT-W 560.0 W 532.2 W 52.7 V 45.9 V 21.71%
FreeVolt ECP-PVGRAF-HC-BF565-144MT-W 565.0 W 537.0 W 52.9 V 46.0 V 21.9%
FreeVolt ECP-PVGRAF-HC-BF570-144MT-W 570.0 W 541.9 W 53.0 V 46.2 V 22.09%

How Many FreeVolt ECP-PVGRAF-HC-BF560-144MT-W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (52.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.7V and beta_Voc=-0.257%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.79 V 10 panels 587.9 V 17 panels
-10 C (14 F) 57.44 V 10 panels 574.4 V 17 panels
0 C (32 F) 56.09 V 10 panels 560.9 V 17 panels
25 C (77 F STC) 52.7 V 11 panels 579.7 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?

Four comparable CEC modules such as Auxin Solar AXN10M560W (560.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M560W
Auxin Solar
560.0 W Tie (0 W) 52.48 V 21.88% 91.8%
Boviet Solar Technology Co Ltd BVM7612M-560-H-HC
Boviet Solar Technology Co Ltd
560.0 W Tie (0 W) 51.66 V 21.71% 95.0%
GermanSolar USA Inc GSM10-144-565W
GermanSolar USA Inc
565.0 W +5.0 W 53.34 V 23.44% 95.1%
Chint New Energy Technology Co Ltd CHSM72N-HC-560
Chint New Energy Technology Co Ltd
560.0 W Tie (0 W) 50.55 V 21.71% 94.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?

Evaluate FreeVolt ECP-PVGRAF-HC-BF560-144MT-W (560.0 W STC, 52.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-HC-BF560-144MT-W reaches 58.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-HC-BF560-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-HC-BF560-144MT-W 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN10M560W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 532.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Why is FreeVolt ECP-PVGRAF-HC-BF560-144MT-W PTC wattage (532.2 W) lower than STC (560.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 532.2 W PTC (95.0% retention) across FreeVolt ECP-PVGRAF-HC-BF560-144MT-W's 2.58 m2 aperture.

Who should skip FreeVolt ECP-PVGRAF-HC-BF560-144MT-W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 FreeVolt ECP-PVGRAF-HC-BF560-144MT-W panels (417 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M560W.

What is the 1,000 V commercial string limit for FreeVolt ECP-PVGRAF-HC-BF560-144MT-W?

On 1,000 V commercial inverters at -10 C (57.44 V cold Voc), FreeVolt ECP-PVGRAF-HC-BF560-144MT-W fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting FreeVolt ECP-PVGRAF-HC-BF560-144MT-W.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.