FreeVolt ECP-PVGRAF-HC-BF560-144MT-B is a 560.0 W STC (532.2 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.71% efficiency, 52.7 V Voc at 25 C, and 57.44 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 532.2 W
- Voc @ 25C
- 52.7 V
- Efficiency
- 21.71%
How Does FreeVolt ECP-PVGRAF-HC-BF560-144MT-B Compare Against Peer CEC Listings?
How FreeVolt FreeVolt ECP-PVGRAF-HC-BF560-144MT-B handles rooftop heat (532.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, FreeVolt ECP-PVGRAF-HC-BF560-144MT-B exhibits 12.84 A short-circuit current, requiring a 20.03 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,404 of 21,677 (150.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.7 m2 for an 8 kW system (18 panels for 10 kW). Higher 52.7 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does FreeVolt ECP-PVGRAF-HC-BF560-144MT-B Fall Across Listed CEC Models?
Where FreeVolt ECP-PVGRAF-HC-BF560-144MT-B (560.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-HC-BF560-144MT-B?
Percentile placement of FreeVolt ECP-PVGRAF-HC-BF560-144MT-B across power density (217.1 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B?
Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-HC-BF560-144MT-B specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.71% Aperture Efficiency
Power density 217.1 W/m2 (1.80 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.44 V at -10 C (574.4 V string) and 58.79 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,983 W PTC; NEC 690.8 OCPD floor is 20.03 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.7 * (1 + (-0.257/100) * (-10 - 25)) = 57.44 V | OCPD = 1.56 * 12.84 = 20.03 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B: Voc=52.7 V, beta_Voc=-0.257%/C, Isc=12.84 A, STC=560.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (574.4 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 532.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 12.84 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.9 V / 12.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.71% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-HC-BF560-144MT-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-HC-BF560-144MT-B (560.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 305 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 417 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 500 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-HC-BF560-144MT-B architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-HC-BF550-144MT-B | 550.0 W | 522.5 W | 52.5 V | 45.6 V | 21.32% |
| FreeVolt ECP-PVGRAF-HC-BF555-144MT-B | 555.0 W | 527.3 W | 52.6 V | 45.8 V | 21.51% |
| FreeVolt ECP-PVGRAF-HC-BF560-144MT-B | 560.0 W | 532.2 W | 52.7 V | 45.9 V | 21.71% |
| FreeVolt ECP-PVGRAF-HC-BF565-144MT-B | 565.0 W | 537.0 W | 52.9 V | 46.0 V | 21.9% |
| FreeVolt ECP-PVGRAF-HC-BF570-144MT-B | 570.0 W | 541.9 W | 53.0 V | 46.2 V | 22.09% |
How Many FreeVolt ECP-PVGRAF-HC-BF560-144MT-B Modules Fit in a Cold-Weather String?
Maximum series module counts for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.79 V | 10 panels | 587.9 V | 17 panels |
| -10 C (14 F) | 57.44 V | 10 panels | 574.4 V | 17 panels |
| 0 C (32 F) | 56.09 V | 10 panels | 560.9 V | 17 panels |
| 25 C (77 F STC) | 52.7 V | 11 panels | 579.7 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-HC-BF560-144MT-B?
Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-HC-BF560-144MT-B (560.0 W), including Auxin Solar AXN10M560W. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M560W Auxin Solar |
560.0 W | Tie (0 W) | 52.48 V | 21.88% | 91.8% |
| Boviet Solar Technology Co Ltd BVM7612M-560-H-HC Boviet Solar Technology Co Ltd |
560.0 W | Tie (0 W) | 51.66 V | 21.71% | 95.0% |
| GermanSolar USA Inc GSM10-144-565W GermanSolar USA Inc |
565.0 W | +5.0 W | 53.34 V | 23.44% | 95.1% |
| Chint New Energy Technology Co Ltd CHSM72N-HC-560 Chint New Energy Technology Co Ltd |
560.0 W | Tie (0 W) | 50.55 V | 21.71% | 94.6% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B?
Evaluate FreeVolt ECP-PVGRAF-HC-BF560-144MT-B (560.0 W STC, 52.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-HC-BF560-144MT-B reaches 58.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-HC-BF560-144MT-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-HC-BF560-144MT-B 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN10M560W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 532.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Why is FreeVolt ECP-PVGRAF-HC-BF560-144MT-B PTC wattage (532.2 W) lower than STC (560.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 532.2 W PTC (95.0% retention) across FreeVolt ECP-PVGRAF-HC-BF560-144MT-B's 2.58 m2 aperture.
Who should skip FreeVolt ECP-PVGRAF-HC-BF560-144MT-B on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 FreeVolt ECP-PVGRAF-HC-BF560-144MT-B panels (417 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M560W.
What is the 1,000 V commercial string limit for FreeVolt ECP-PVGRAF-HC-BF560-144MT-B?
On 1,000 V commercial inverters at -10 C (57.44 V cold Voc), FreeVolt ECP-PVGRAF-HC-BF560-144MT-B fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting FreeVolt ECP-PVGRAF-HC-BF560-144MT-B.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)