FreeVolt ECP-PVGRAF-HC-BF585-144MT-B is a 585.0 W STC (556.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 53.4 V Voc at 25 C, and 58.2 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 556.5 W
- Voc @ 25C
- 53.4 V
- Efficiency
- 22.67%
How Does FreeVolt ECP-PVGRAF-HC-BF585-144MT-B Compare Against Peer CEC Listings?
Engineering position of FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (585.0 W STC) vs. Allesun Industries Inc Allesun-585-78IIMBG across 5,889 CEC Mono-c-Si solar modules.
Built with 24 Mono-c-Si cells, FreeVolt ECP-PVGRAF-HC-BF585-144MT-B pairs strong 95.1% PTC-to-STC heat retention (#713 of 21,677) with 53.4 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,791 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Allesun Industries Inc Allesun-585-78IIMBG offers a 585.0 W alternative.
Where Does FreeVolt ECP-PVGRAF-HC-BF585-144MT-B Fall Across Listed CEC Models?
Plots FreeVolt ECP-PVGRAF-HC-BF585-144MT-B at 585.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?
Benchmarks FreeVolt ECP-PVGRAF-HC-BF585-144MT-B on STC wattage, thermal PTC/STC retention, and 22.67 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B by FreeVolt.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.2 V at -10 C (582.0 V string) and 59.58 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,791 W PTC; NEC 690.8 OCPD floor is 20.65 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.4 * (1 + (-0.257/100) * (-10 - 25)) = 58.2 V | OCPD = 1.56 * 13.24 = 20.65 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B: Voc=53.4 V, beta_Voc=-0.257%/C, Isc=13.24 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (582.0 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?
Laboratory test ratings recorded for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 556.5 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.6 V / 12.55 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-HC-BF585-144MT-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (389 sq ft at 8 kW), and estimated Year-1 electric bill offset for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
Sibling wattage bins and frame colors grouped with FreeVolt ECP-PVGRAF-HC-BF585-144MT-B under FreeVolt to prevent duplicate spec pages. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-HC-BF575-144MT-B | 575.0 W | 546.8 W | 53.2 V | 46.3 V | 22.29% |
| FreeVolt ECP-PVGRAF-HC-BF580-144MT-B | 580.0 W | 551.6 W | 53.3 V | 46.5 V | 22.48% |
| FreeVolt ECP-PVGRAF-HC-BF585-144MT-B | 585.0 W | 556.5 W | 53.4 V | 46.6 V | 22.67% |
| FreeVolt ECP-PVGRAF-HC-BF590-144MT-B | 590.0 W | 561.3 W | 53.6 V | 46.8 V | 22.87% |
How Many FreeVolt ECP-PVGRAF-HC-BF585-144MT-B Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (beta_Voc -0.257%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.58 V | 10 panels | 595.8 V | 16 panels |
| -10 C (14 F) | 58.2 V | 10 panels | 582.0 V | 17 panels |
| 0 C (32 F) | 56.83 V | 10 panels | 568.3 V | 17 panels |
| 25 C (77 F STC) | 53.4 V | 11 panels | 587.4 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?
Closest cross-brand CEC competitors to FreeVolt ECP-PVGRAF-HC-BF585-144MT-B matched near 585.0 W STC and 53.4 V Voc, led by Allesun Industries Inc Allesun-585-78IIMBG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Allesun Industries Inc Allesun-585-78IIMBG Allesun Industries Inc |
585.0 W | Tie (0 W) | 53.73 V | 20.97% | 94.0% |
| G-Star Pte Ltd GSD7G78M-585BT G-Star Pte Ltd |
585.0 W | Tie (0 W) | 53.73 V | 21.12% | 94.3% |
| G-Star Pte Ltd GSD7G78M-585WT G-Star Pte Ltd |
585.0 W | Tie (0 W) | 53.73 V | 21.12% | 94.3% |
| G-Star Pte Ltd GSD7S72T-585BT G-Star Pte Ltd |
585.0 W | Tie (0 W) | 52.85 V | 22.85% | 95.2% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?
Evaluate FreeVolt ECP-PVGRAF-HC-BF585-144MT-B (585.0 W STC, 53.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-HC-BF585-144MT-B reaches 59.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-HC-BF585-144MT-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-HC-BF585-144MT-B 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Allesun Industries Inc Allesun-585-78IIMBG.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B?
Multiplying FreeVolt ECP-PVGRAF-HC-BF585-144MT-B's 13.24 A short-circuit current by 1.56 equals 20.65 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-HC-BF585-144MT-B before finalizing component orders.
Can FreeVolt ECP-PVGRAF-HC-BF585-144MT-B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 58.2 V cold Voc at 14 F and handles 13.24 A Isc; string inverters cap FreeVolt ECP-PVGRAF-HC-BF585-144MT-B at 10 panels on 600 V.
Is FreeVolt ECP-PVGRAF-HC-BF585-144MT-B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-HC-BF585-144MT-B rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)