Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-HC-BF585-144MT-W is a 585.0 W STC (556.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 53.4 V Voc at 25 C, and 58.2 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
585.0 W
PTC Wattage
556.5 W
Voc @ 25C
53.4 V
Efficiency
22.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Compare Against Peer CEC Listings?

How FreeVolt FreeVolt ECP-PVGRAF-HC-BF585-144MT-W handles rooftop heat (556.5 W PTC), 8 kW sizing, and cold winter string voltage.

FreeVolt builds the FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (Mono-c-Si) as a large-format commercial and ground-mount module delivering 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). Compared against Allesun Industries Inc Allesun-585-78IIMBG (585.0 W), this model holds strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Higher 53.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 20.65 A overcurrent floor served by a 25 A breaker.

Where Does FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Fall Across Listed CEC Models?

Where FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 585.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?

Percentile placement of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W across power density (226.7 W/m2), thermal retention, and nameplate STC wattage. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage585.0 WPTC/STC Retention95.1%Module Efficiency22.67%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?

Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-HC-BF585-144MT-W specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #1,751 / 21,677

Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,698

22.67% Aperture Efficiency

Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.2 V at -10 C (582.0 V string) and 59.58 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,190 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,791 W PTC; NEC 690.8 OCPD floor is 20.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.4 * (1 + (-0.257/100) * (-10 - 25)) = 58.2 V | OCPD = 1.56 * 13.24 = 20.65 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W: Voc=53.4 V, beta_Voc=-0.257%/C, Isc=13.24 A, STC=585.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (582.0 V); 14 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 585.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 556.5 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.6 V / 12.55 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.257 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.67% (2.58 m2) Array roof footprint density
Cell Count & Technology 24 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.43 kW 305 sq ft $1,609 $2,721
8 kW Class 14 8.19 kW 389 sq ft $2,050 $3,466
10 kW Class 18 10.53 kW 500 sq ft $2,636 $4,457

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-HC-BF585-144MT-W architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-HC-BF585-144MT-W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-HC-BF575-144MT-W 575.0 W 546.8 W 53.2 V 46.3 V 22.29%
FreeVolt ECP-PVGRAF-HC-BF580-144MT-W 580.0 W 551.6 W 53.3 V 46.5 V 22.48%
FreeVolt ECP-PVGRAF-HC-BF585-144MT-W 585.0 W 556.5 W 53.4 V 46.6 V 22.67%
FreeVolt ECP-PVGRAF-HC-BF590-144MT-W 590.0 W 561.3 W 53.6 V 46.8 V 22.87%

How Many FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Modules Fit in a Cold-Weather String?

Maximum series module counts for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.4V and beta_Voc=-0.257%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.58 V 10 panels 595.8 V 16 panels
-10 C (14 F) 58.2 V 10 panels 582.0 V 17 panels
0 C (32 F) 56.83 V 10 panels 568.3 V 17 panels
25 C (77 F STC) 53.4 V 11 panels 587.4 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?

Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W), including Allesun Industries Inc Allesun-585-78IIMBG. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Allesun Industries Inc Allesun-585-78IIMBG
Allesun Industries Inc
585.0 W Tie (0 W) 53.73 V 20.97% 94.0%
G-Star Pte Ltd GSD7G78M-585BT
G-Star Pte Ltd
585.0 W Tie (0 W) 53.73 V 21.12% 94.3%
G-Star Pte Ltd GSD7G78M-585WT
G-Star Pte Ltd
585.0 W Tie (0 W) 53.73 V 21.12% 94.3%
G-Star Pte Ltd GSD7S72T-585BT
G-Star Pte Ltd
585.0 W Tie (0 W) 52.85 V 22.85% 95.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?

Evaluate FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W STC, 53.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-HC-BF585-144MT-W reaches 59.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-HC-BF585-144MT-W 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Allesun Industries Inc Allesun-585-78IIMBG.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?

Multiplying FreeVolt ECP-PVGRAF-HC-BF585-144MT-W's 13.24 A short-circuit current by 1.56 equals 20.65 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-HC-BF585-144MT-W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 58.2 V cold Voc at 14 F and handles 13.24 A Isc; string inverters cap FreeVolt ECP-PVGRAF-HC-BF585-144MT-W at 10 panels on 600 V.

Is FreeVolt ECP-PVGRAF-HC-BF585-144MT-W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.