FreeVolt ECP-PVGRAF-HC-BF585-144MT-W is a 585.0 W STC (556.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 53.4 V Voc at 25 C, and 58.2 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 556.5 W
- Voc @ 25C
- 53.4 V
- Efficiency
- 22.67%
How Does FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Compare Against Peer CEC Listings?
How FreeVolt FreeVolt ECP-PVGRAF-HC-BF585-144MT-W handles rooftop heat (556.5 W PTC), 8 kW sizing, and cold winter string voltage.
FreeVolt builds the FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (Mono-c-Si) as a large-format commercial and ground-mount module delivering 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). Compared against Allesun Industries Inc Allesun-585-78IIMBG (585.0 W), this model holds strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Higher 53.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 20.65 A overcurrent floor served by a 25 A breaker.
Where Does FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Fall Across Listed CEC Models?
Where FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?
Percentile placement of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W across power density (226.7 W/m2), thermal retention, and nameplate STC wattage. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?
Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-HC-BF585-144MT-W specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.2 V at -10 C (582.0 V string) and 59.58 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,791 W PTC; NEC 690.8 OCPD floor is 20.65 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.4 * (1 + (-0.257/100) * (-10 - 25)) = 58.2 V | OCPD = 1.56 * 13.24 = 20.65 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W: Voc=53.4 V, beta_Voc=-0.257%/C, Isc=13.24 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (582.0 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 556.5 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.6 V / 12.55 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.257 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
All closely matched FreeVolt wattages and cosmetic trims sharing the FreeVolt ECP-PVGRAF-HC-BF585-144MT-W architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-HC-BF575-144MT-W | 575.0 W | 546.8 W | 53.2 V | 46.3 V | 22.29% |
| FreeVolt ECP-PVGRAF-HC-BF580-144MT-W | 580.0 W | 551.6 W | 53.3 V | 46.5 V | 22.48% |
| FreeVolt ECP-PVGRAF-HC-BF585-144MT-W | 585.0 W | 556.5 W | 53.4 V | 46.6 V | 22.67% |
| FreeVolt ECP-PVGRAF-HC-BF590-144MT-W | 590.0 W | 561.3 W | 53.6 V | 46.8 V | 22.87% |
How Many FreeVolt ECP-PVGRAF-HC-BF585-144MT-W Modules Fit in a Cold-Weather String?
Maximum series module counts for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.58 V | 10 panels | 595.8 V | 16 panels |
| -10 C (14 F) | 58.2 V | 10 panels | 582.0 V | 17 panels |
| 0 C (32 F) | 56.83 V | 10 panels | 568.3 V | 17 panels |
| 25 C (77 F STC) | 53.4 V | 11 panels | 587.4 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?
Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W), including Allesun Industries Inc Allesun-585-78IIMBG. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Allesun Industries Inc Allesun-585-78IIMBG Allesun Industries Inc |
585.0 W | Tie (0 W) | 53.73 V | 20.97% | 94.0% |
| G-Star Pte Ltd GSD7G78M-585BT G-Star Pte Ltd |
585.0 W | Tie (0 W) | 53.73 V | 21.12% | 94.3% |
| G-Star Pte Ltd GSD7G78M-585WT G-Star Pte Ltd |
585.0 W | Tie (0 W) | 53.73 V | 21.12% | 94.3% |
| G-Star Pte Ltd GSD7S72T-585BT G-Star Pte Ltd |
585.0 W | Tie (0 W) | 52.85 V | 22.85% | 95.2% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?
Evaluate FreeVolt ECP-PVGRAF-HC-BF585-144MT-W (585.0 W STC, 53.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-HC-BF585-144MT-W reaches 59.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-HC-BF585-144MT-W 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Allesun Industries Inc Allesun-585-78IIMBG.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W?
Multiplying FreeVolt ECP-PVGRAF-HC-BF585-144MT-W's 13.24 A short-circuit current by 1.56 equals 20.65 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-HC-BF585-144MT-W before finalizing component orders.
Can FreeVolt ECP-PVGRAF-HC-BF585-144MT-W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 58.2 V cold Voc at 14 F and handles 13.24 A Isc; string inverters cap FreeVolt ECP-PVGRAF-HC-BF585-144MT-W at 10 panels on 600 V.
Is FreeVolt ECP-PVGRAF-HC-BF585-144MT-W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-HC-BF585-144MT-W rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)