Skip to main content
WireAndSun
Calculators
CEC PV Module

FreeVolt ECP-PVGRAF-144BHC-450W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-144BHC-450W is a 450.0 W STC (416.9 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.03% efficiency, 49.6 V Voc at 25 C, and 55.02 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
450.0 W
PTC Wattage
416.9 W
Voc @ 25C
49.6 V
Efficiency
21.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-144BHC-450W Compare Against Peer CEC Listings?

Solar engineering breakdown for FreeVolt ECP-PVGRAF-144BHC-450W: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-144BHC-450W stands 40.0 W above the 410.0 W Mono-c-Si median and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,577-$2,591/yr in baseline US bill offset. Higher 49.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does FreeVolt ECP-PVGRAF-144BHC-450W Fall Across Listed CEC Models?

Distribution marker showing FreeVolt ECP-PVGRAF-144BHC-450W (450.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-144BHC-450W (450.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 450.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-144BHC-450W?

Dataset percentiles tracking FreeVolt ECP-PVGRAF-144BHC-450W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

FreeVolt ECP-PVGRAF-144BHC-450W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-144BHC-450W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage450.0 WPTC/STC Retention92.6%Module Efficiency21.03%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-144BHC-450W?

Benchmark highlights for FreeVolt ECP-PVGRAF-144BHC-450W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #5,679 / 21,677

Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.02 V at -10 C (550.2 V string) and 56.56 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,100 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 18.06 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.312/100) * (-10 - 25)) = 55.02 V | OCPD = 1.56 * 11.58 = 18.06 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-144BHC-450W: Voc=49.6 V, beta_Voc=-0.312%/C, Isc=11.58 A, STC=450.0 W, Area=2.14 m2.

Result: 10 panels max on 600 V (550.2 V); 18 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-144BHC-450W?

Official CEC datasheet figures for FreeVolt ECP-PVGRAF-144BHC-450W (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-144BHC-450W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 450.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 416.9 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.4 V / 10.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.312 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.03% (2.14 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-144BHC-450W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many FreeVolt ECP-PVGRAF-144BHC-450W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.3 kW 322 sq ft $1,577 $2,666
8 kW Class 18 8.1 kW 415 sq ft $2,027 $3,428
10 kW Class 23 10.35 kW 530 sq ft $2,591 $4,380

How Many FreeVolt ECP-PVGRAF-144BHC-450W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-144BHC-450W (55.02 V at 14 F). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Computed from Voc=49.6V and beta_Voc=-0.312%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.56 V 10 panels 565.6 V 17 panels
-10 C (14 F) 55.02 V 10 panels 550.2 V 18 panels
0 C (32 F) 53.47 V 11 panels 588.2 V 18 panels
25 C (77 F STC) 49.6 V 12 panels 595.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-144BHC-450W?

Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-144BHC-450W in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
450.0 W Tie (0 W) 49.6 V 21.03% 92.6%
AXITEC AC-450MB/144V
AXITEC
450.0 W Tie (0 W) 49.6 V 21.03% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 450W
Dehui Solar Power (Vietnam) CoLtd
450.0 W Tie (0 W) 49.6 V 21.03% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-144BHC-450W?

Evaluate FreeVolt ECP-PVGRAF-144BHC-450W (450.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-144BHC-450W reaches 56.56 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-144BHC-450W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-144BHC-450W 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-144BHC-450W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-144BHC-450W?

Multiplying FreeVolt ECP-PVGRAF-144BHC-450W's 11.58 A short-circuit current by 1.56 equals 18.06 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-144BHC-450W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-144BHC-450W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.02 V cold Voc at 14 F and handles 11.58 A Isc; string inverters cap FreeVolt ECP-PVGRAF-144BHC-450W at 10 panels on 600 V.

Is FreeVolt ECP-PVGRAF-144BHC-450W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-144BHC-450W rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.