AXITEC AC-450MB/144V is a 450.0 W STC (416.9 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.03% efficiency, 49.6 V Voc at 25 C, and 55.02 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 416.9 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 21.03%
How Does AXITEC AC-450MB/144V Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-450MB/144V (450.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W across 5,889 CEC Mono-c-Si solar modules.
Ranking #5,679 across 21,677 CEC solar panels (top 27.8%; higher than 72.2% of peers), AXITEC AC-450MB/144V operates as a modern high-density residential and light-commercial module sitting 40.0 W above the 410.0 W Mono-c-Si median. Higher 49.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), 18 panels occupy 415 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-450MB/144V Fall Across Listed CEC Models?
Plots AXITEC AC-450MB/144V at 450.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-450MB/144V?
Benchmarks AXITEC AC-450MB/144V on STC wattage, thermal PTC/STC retention, and 21.03 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-450MB/144V?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-450MB/144V by AXITEC.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.02 V at -10 C (550.2 V string) and 56.56 V at -20 C (10 max).
18 Panels = 8,100 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 18.06 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.312/100) * (-10 - 25)) = 55.02 V | OCPD = 1.56 * 11.58 = 18.06 A
Inputs from CEC Modules.csv for AXITEC AC-450MB/144V: Voc=49.6 V, beta_Voc=-0.312%/C, Isc=11.58 A, STC=450.0 W, Area=2.14 m2.
Result: 10 panels max on 600 V (550.2 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for AXITEC AC-450MB/144V?
Laboratory test ratings recorded for AXITEC AC-450MB/144V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 416.9 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.4 V / 10.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-450MB/144V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (415 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-450MB/144V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 322 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 415 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 530 sq ft | $2,591 | $4,380 |
How Many AXITEC AC-450MB/144V Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-450MB/144V (beta_Voc -0.312%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.56 V | 10 panels | 565.6 V | 17 panels |
| -10 C (14 F) | 55.02 V | 10 panels | 550.2 V | 18 panels |
| 0 C (32 F) | 53.47 V | 11 panels | 588.2 V | 18 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-450MB/144V?
Closest cross-brand CEC competitors to AXITEC AC-450MB/144V matched near 450.0 W STC and 49.6 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
450.0 W | Tie (0 W) | 49.6 V | 21.03% | 92.6% |
| Dehui Solar Power (Vietnam) CoLtd DH-M772F 450W Dehui Solar Power (Vietnam) CoLtd |
450.0 W | Tie (0 W) | 49.6 V | 21.03% | 92.6% |
| FreeVolt ECP-PVGRAF-144BHC-450W FreeVolt |
450.0 W | Tie (0 W) | 49.6 V | 21.03% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-450MB/144V?
Evaluate AXITEC AC-450MB/144V (450.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-450MB/144V reaches 56.56 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-450MB/144V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-450MB/144V 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-450MB/144V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-450MB/144V panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-450MB/144V cold Voc rises from 49.6 V to 55.02 V (beta_Voc -0.312%/C), capping a 600 V string at 10 panels (550.2 V).
How much roof area does an 8 kW array of AXITEC AC-450MB/144V need?
An 8 kW DC system uses 18 AXITEC AC-450MB/144V modules (8,100 W STC / 7,504 W PTC), covering roughly 415 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does AXITEC AC-450MB/144V compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W?
AXITEC AC-450MB/144V outputs 450.0 W STC (49.6 V Voc, rank #5,679 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W delivers 450.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)