CertainTeed CT300M10-03 is a 300.0 W STC (277.2 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.55% efficiency, 40.3 V Voc at 25 C, and 44.24 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 277.2 W
- Voc @ 25C
- 40.3 V
- Efficiency
- 18.55%
How Does CertainTeed CT300M10-03 Compare Against Peer CEC Listings?
How CertainTeed CertainTeed CT300M10-03 handles rooftop heat (277.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, CertainTeed CT300M10-03 exhibits 9.75 A short-circuit current, requiring a 15.21 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #16,498 of 21,677 (110.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.7 m2 for an 8 kW system (34 panels for 10 kW). Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does CertainTeed CT300M10-03 Fall Across Listed CEC Models?
Where CertainTeed CT300M10-03 (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CertainTeed CT300M10-03?
Percentile placement of CertainTeed CT300M10-03 across power density (185.5 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for CertainTeed CT300M10-03?
Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed CT300M10-03 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.55% Aperture Efficiency
Power density 185.5 W/m2 (1.36 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.24 V at -10 C (575.1 V string) and 45.36 V at -20 C (13 max).
27 Panels = 8,100 W STC
Occupies 43.7 m2 (470 sq ft) producing 7,484 W PTC; NEC 690.8 OCPD floor is 15.21 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.3 * (1 + (-0.279/100) * (-10 - 25)) = 44.24 V | OCPD = 1.56 * 9.75 = 15.21 A
Inputs from CEC Modules.csv for CertainTeed CT300M10-03: Voc=40.3 V, beta_Voc=-0.279%/C, Isc=9.75 A, STC=300.0 W, Area=1.617 m2.
Result: 13 panels max on 600 V (575.1 V); 27 panels for 8 kW (470 sq ft).
What Are the Published CEC Specifications for CertainTeed CT300M10-03?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed CT300M10-03. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 277.2 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.5 V / 9.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.55% (1.617 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed CT300M10-03 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed CT300M10-03 (300.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 348 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 470 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 592 sq ft | $2,553 | $4,317 |
How Many CertainTeed CT300M10-03 Modules Fit in a Cold-Weather String?
Maximum series module counts for CertainTeed CT300M10-03 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.36 V | 13 panels | 589.7 V | 22 panels |
| -10 C (14 F) | 44.24 V | 13 panels | 575.1 V | 22 panels |
| 0 C (32 F) | 43.11 V | 13 panels | 560.4 V | 23 panels |
| 25 C (77 F STC) | 40.3 V | 14 panels | 564.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed CT300M10-03?
Alternative CEC solar modules from competing brands near CertainTeed CT300M10-03 (300.0 W), including Enphase Energy Inc XACM-IQ7-LR6-60PB-300M. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Enphase Energy Inc |
300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| FreeVolt PV-GRAF-60M6-300/M FreeVolt |
300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| DEHUI SOLAR POWER INC DH-60M-305W DEHUI SOLAR POWER INC |
305.0 W | +5.0 W | 40.3 V | 18.94% | 91.4% |
| Enphase Energy Inc XACM-IQ7-LR6-60PB-305M Enphase Energy Inc |
305.0 W | +5.0 W | 40.2 V | 19.3% | 91.4% |
What Are the Design Limits and Best-Fit Uses for CertainTeed CT300M10-03?
Evaluate CertainTeed CT300M10-03 (300.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CT300M10-03 reaches 45.36 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (470 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed CT300M10-03 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed CT300M10-03 8 kW Residential Fit
Needs 27 modules (470 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 277.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed CT300M10-03 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Why is CertainTeed CT300M10-03 PTC wattage (277.2 W) lower than STC (300.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 277.2 W PTC (92.4% retention) across CertainTeed CT300M10-03's 1.617 m2 aperture.
Who should skip CertainTeed CT300M10-03 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 CertainTeed CT300M10-03 panels (470 sq ft) leave unusable roof gaps vs. Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.
What is the 1,000 V commercial string limit for CertainTeed CT300M10-03?
On 1,000 V commercial inverters at -10 C (44.24 V cold Voc), CertainTeed CT300M10-03 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting CertainTeed CT300M10-03.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)