CertainTeed CT300M10-01 — CEC Solar Module Specifications

Manufacturer: CertainTeed Registry: CEC Verified Engineering Specification

CertainTeed CT300M10-01 is a 300.0 W STC (272.9 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.33% efficiency, 39.1 V Voc at 25 C, and 43.11 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
272.9 W
Voc @ 25C
39.1 V
Efficiency
18.33%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed CT300M10-01 Compare Against Peer CEC Listings?

Solar engineering breakdown for CertainTeed CT300M10-01: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Measured at 300.0 W STC and 272.9 W PTC, CertainTeed CT300M10-01 sits -85.0 W vs all-CEC median (below all-CEC median; higher than 22.1% of peers) among 21,677 listed modules. Power density reaches 183.3 W/m2 (1.58 percentage points below 19.91% CEC median). Lower 39.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer FreeVolt PV-GRAF-60M6-300/M rates 300.0 W.

Where Does CertainTeed CT300M10-01 Fall Across Listed CEC Models?

Distribution marker showing CertainTeed CT300M10-01 (300.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed CT300M10-01 (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed CT300M: 300.0 W

What Dataset Percentiles Define CertainTeed CT300M10-01?

Dataset percentiles tracking CertainTeed CT300M10-01 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

CertainTeed CT300M10-01 Engineering BenchmarksPercentile comparison of CertainTeed CT300M10-01 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention91.0%Module Efficiency18.33%

What Do the Dataset Ranks Show for CertainTeed CT300M10-01?

Benchmark highlights for CertainTeed CT300M10-01 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #14,597

18.33% Aperture Efficiency

Power density 183.3 W/m2 (1.58 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.11 V at -10 C (560.4 V string) and 44.26 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 44.2 m2 (476 sq ft) producing 7,368 W PTC; NEC 690.8 OCPD floor is 15.44 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.293/100) * (-10 - 25)) = 43.11 V | OCPD = 1.56 * 9.9 = 15.44 A

Inputs from CEC Modules.csv for CertainTeed CT300M10-01: Voc=39.1 V, beta_Voc=-0.293%/C, Isc=9.9 A, STC=300.0 W, Area=1.637 m2.

Result: 13 panels max on 600 V (560.4 V); 27 panels for 8 kW (476 sq ft).

What Are the Published CEC Specifications for CertainTeed CT300M10-01?

Official CEC datasheet figures for CertainTeed CT300M10-01 (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed CT300M10-01.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 272.9 W (91.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.3 V / 9.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.293 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.33% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many CertainTeed CT300M10-01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many CertainTeed CT300M10-01 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 352 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 476 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 599 sq ft $2,553 $4,317

How Many CertainTeed CT300M10-01 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed CT300M10-01 (43.11 V at 14 F). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Computed from Voc=39.1V and beta_Voc=-0.293%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.26 V 13 panels 575.4 V 22 panels
-10 C (14 F) 43.11 V 13 panels 560.4 V 23 panels
0 C (32 F) 41.96 V 14 panels 587.4 V 23 panels
25 C (77 F STC) 39.1 V 15 panels 586.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed CT300M10-01?

Competing CEC solar panels closest to CertainTeed CT300M10-01 in nameplate wattage and Voc, starting with FreeVolt PV-GRAF-60M6-300/M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
FreeVolt PV-GRAF-60M6-300/M
FreeVolt
300.0 W Tie (0 W) 39.6 V 18.29% 91.1%
Enphase Energy Inc XACM-IQ7-LR6-60PB-300M
Enphase Energy Inc
300.0 W Tie (0 W) 40.1 V 18.99% 91.1%
AXITEC AC-305M/60S
AXITEC
305.0 W +5.0 W 39.81 V 18.75% 91.2%
AXITEC AC-305M/60V
AXITEC
305.0 W +5.0 W 39.81 V 18.75% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed CT300M10-01?

Evaluate CertainTeed CT300M10-01 (300.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CT300M10-01 reaches 44.26 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (476 sq ft).
  • 2026 tax credit baseline: cash residential installs of CertainTeed CT300M10-01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed CT300M10-01 8 kW Residential Fit

Needs 27 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare FreeVolt PV-GRAF-60M6-300/M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 272.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed CT300M10-01 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

How many CertainTeed CT300M10-01 panels fit on a 600 V winter solar string?

At -10 C (14 F), CertainTeed CT300M10-01 cold Voc rises from 39.1 V to 43.11 V (beta_Voc -0.293%/C), capping a 600 V string at 13 panels (560.4 V).

How much roof area does an 8 kW array of CertainTeed CT300M10-01 need?

An 8 kW DC system uses 27 CertainTeed CT300M10-01 modules (8,100 W STC / 7,368 W PTC), covering roughly 476 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does CertainTeed CT300M10-01 compare against FreeVolt PV-GRAF-60M6-300/M?

CertainTeed CT300M10-01 outputs 300.0 W STC (39.1 V Voc, rank #16,498 of 21,677), while FreeVolt PV-GRAF-60M6-300/M delivers 300.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.