AXITEC AC-305M/60V is a 305.0 W STC (278.1 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 18.75% efficiency, 39.81 V Voc at 25 C, and 44.03 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 305.0 W
- PTC Wattage
- 278.1 W
- Voc @ 25C
- 39.81 V
- Efficiency
- 18.75%
How Does AXITEC AC-305M/60V Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-305M/60V (Mono-c-Si) residential solar systems.
Homeowners evaluating AXITEC AC-305M/60V need 20 panels for 6 kW or 27 panels (473 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (473 sq ft). Under NEC 690.7(A), beta_Voc (-0.303%/C) pushes open-circuit voltage to 44.03 V at 14 F and 45.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-305M/60V Fall Across Listed CEC Models?
Comparison of AXITEC AC-305M/60V (305.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define AXITEC AC-305M/60V?
Relative ranking of AXITEC AC-305M/60V across nameplate watts, 91.2% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for AXITEC AC-305M/60V?
Summary of AXITEC AC-305M/60V output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.
305.0 W STC · Higher Than 23.9%
305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.75% Aperture Efficiency
Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.03 V at -10 C (572.4 V string) and 45.24 V at -20 C (13 max).
27 Panels = 8,235 W STC
Occupies 43.9 m2 (473 sq ft) producing 7,509 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.81 * (1 + (-0.303/100) * (-10 - 25)) = 44.03 V | OCPD = 1.56 * 9.83 = 15.33 A
Inputs from CEC Modules.csv for AXITEC AC-305M/60V: Voc=39.81 V, beta_Voc=-0.303%/C, Isc=9.83 A, STC=305.0 W, Area=1.627 m2.
Result: 13 panels max on 600 V (572.4 V); 27 panels for 8 kW (473 sq ft).
What Are the Published CEC Specifications for AXITEC AC-305M/60V?
Complete CEC test sheet for AXITEC AC-305M/60V including Isc (9.83 A), Voc (39.81 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 305.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 278.1 W (91.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.41 V / 9.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.75% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-305M/60V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-305M/60V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.1 kW | 350 sq ft | $1,527 | $2,582 |
| 8 kW Class | 27 | 8.23 kW | 473 sq ft | $2,060 | $3,483 |
| 10 kW Class | 33 | 10.06 kW | 578 sq ft | $2,518 | $4,258 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-305M/60V series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-300M/60V | 300.0 W | 273.4 W | 39.72 V | 32.37 V | 18.44% |
| AXITEC AC-305M/60V | 305.0 W | 278.1 W | 39.81 V | 32.41 V | 18.75% |
| AXITEC AC-310M/60V | 310.0 W | 282.9 W | 39.9 V | 32.46 V | 19.05% |
How Many AXITEC AC-305M/60V Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for AXITEC AC-305M/60V (39.81 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.24 V | 13 panels | 588.1 V | 22 panels |
| -10 C (14 F) | 44.03 V | 13 panels | 572.4 V | 22 panels |
| 0 C (32 F) | 42.83 V | 14 panels | 599.6 V | 23 panels |
| 25 C (77 F STC) | 39.81 V | 15 panels | 597.2 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-305M/60V?
Four comparable CEC modules such as DuCal Solar Technology LLC DST305M-60 (305.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DuCal Solar Technology LLC DST305M-60 DuCal Solar Technology LLC |
305.0 W | Tie (0 W) | 40.0 V | 18.75% | 90.3% |
| Enphase Energy Inc XACM-IQ7-LR6-60PB-305M Enphase Energy Inc |
305.0 W | Tie (0 W) | 40.2 V | 19.3% | 91.4% |
| DEHUI SOLAR POWER INC DH-60M-305W DEHUI SOLAR POWER INC |
305.0 W | Tie (0 W) | 40.3 V | 18.94% | 91.4% |
| CertainTeed CT305M10-02 CertainTeed |
305.0 W | Tie (0 W) | 40.79 V | 18.75% | 91.7% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-305M/60V?
Evaluate AXITEC AC-305M/60V (305.0 W STC, 39.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-305M/60V reaches 45.24 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 473 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (473 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-305M/60V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-305M/60V 8 kW Residential Fit
Needs 27 modules (473 sq ft) with a 20 A string OCPD, offsetting ~$2,060/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DuCal Solar Technology LLC DST305M-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 278.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-305M/60V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is AXITEC AC-305M/60V PTC wattage (278.1 W) lower than STC (305.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 278.1 W PTC (91.2% retention) across AXITEC AC-305M/60V's 1.627 m2 aperture.
Who should skip AXITEC AC-305M/60V on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 AXITEC AC-305M/60V panels (473 sq ft) leave unusable roof gaps vs. DuCal Solar Technology LLC DST305M-60.
What is the 1,000 V commercial string limit for AXITEC AC-305M/60V?
On 1,000 V commercial inverters at -10 C (44.03 V cold Voc), AXITEC AC-305M/60V fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-305M/60V.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)