CertainTeed CT305M10-02 is a 305.0 W STC (279.8 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 18.75% efficiency, 40.79 V Voc at 25 C, and 44.82 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 305.0 W
- PTC Wattage
- 279.8 W
- Voc @ 25C
- 40.79 V
- Efficiency
- 18.75%
How Does CertainTeed CT305M10-02 Compare Against Peer CEC Listings?
How CertainTeed CertainTeed CT305M10-02 handles rooftop heat (279.8 W PTC), 8 kW sizing, and cold winter string voltage.
CertainTeed builds the CertainTeed CT305M10-02 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). Compared against DEHUI SOLAR POWER INC DH-60M-305W (305.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Mid-range 40.79 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.69 A overcurrent floor served by a 20 A breaker.
Where Does CertainTeed CT305M10-02 Fall Across Listed CEC Models?
Where CertainTeed CT305M10-02 (305.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CertainTeed CT305M10-02?
Percentile placement of CertainTeed CT305M10-02 across power density (187.5 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for CertainTeed CT305M10-02?
Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed CT305M10-02 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
305.0 W STC · Higher Than 23.9%
305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.75% Aperture Efficiency
Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.82 V at -10 C (582.7 V string) and 45.97 V at -20 C (13 max).
27 Panels = 8,235 W STC
Occupies 43.9 m2 (473 sq ft) producing 7,555 W PTC; NEC 690.8 OCPD floor is 15.69 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.79 * (1 + (-0.282/100) * (-10 - 25)) = 44.82 V | OCPD = 1.56 * 10.06 = 15.69 A
Inputs from CEC Modules.csv for CertainTeed CT305M10-02: Voc=40.79 V, beta_Voc=-0.282%/C, Isc=10.06 A, STC=305.0 W, Area=1.627 m2.
Result: 13 panels max on 600 V (582.7 V); 27 panels for 8 kW (473 sq ft).
What Are the Published CEC Specifications for CertainTeed CT305M10-02?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed CT305M10-02. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 305.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 279.8 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.79 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.73 V / 9.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.75% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed CT305M10-02 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed CT305M10-02 (305.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.1 kW | 350 sq ft | $1,527 | $2,582 |
| 8 kW Class | 27 | 8.23 kW | 473 sq ft | $2,060 | $3,483 |
| 10 kW Class | 33 | 10.06 kW | 578 sq ft | $2,518 | $4,258 |
Which Sibling Wattage & Trim Variants Belong to This CertainTeed Series?
All closely matched CertainTeed wattages and cosmetic trims sharing the CertainTeed CT305M10-02 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CertainTeed CT300M10-02 | 300.0 W | 275.1 W | 40.45 V | 32.48 V | 18.44% |
| CertainTeed CT305M10-02 | 305.0 W | 279.8 W | 40.79 V | 32.73 V | 18.75% |
How Many CertainTeed CT305M10-02 Modules Fit in a Cold-Weather String?
Maximum series module counts for CertainTeed CT305M10-02 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.97 V | 13 panels | 597.6 V | 21 panels |
| -10 C (14 F) | 44.82 V | 13 panels | 582.7 V | 22 panels |
| 0 C (32 F) | 43.67 V | 13 panels | 567.7 V | 22 panels |
| 25 C (77 F STC) | 40.79 V | 14 panels | 571.1 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed CT305M10-02?
Alternative CEC solar modules from competing brands near CertainTeed CT305M10-02 (305.0 W), including DEHUI SOLAR POWER INC DH-60M-305W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DEHUI SOLAR POWER INC DH-60M-305W DEHUI SOLAR POWER INC |
305.0 W | Tie (0 W) | 40.3 V | 18.94% | 91.4% |
| Enphase Energy Inc XACM-IQ7-LR6-60PB-305M Enphase Energy Inc |
305.0 W | Tie (0 W) | 40.2 V | 19.3% | 91.4% |
| DuCal Solar Technology LLC DST305M-60 DuCal Solar Technology LLC |
305.0 W | Tie (0 W) | 40.0 V | 18.75% | 90.3% |
| AXITEC AC-305M/60S AXITEC |
305.0 W | Tie (0 W) | 39.81 V | 18.75% | 91.2% |
What Are the Design Limits and Best-Fit Uses for CertainTeed CT305M10-02?
Evaluate CertainTeed CT305M10-02 (305.0 W STC, 40.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CT305M10-02 reaches 45.97 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 473 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (473 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed CT305M10-02 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed CT305M10-02 8 kW Residential Fit
Needs 27 modules (473 sq ft) with a 20 A string OCPD, offsetting ~$2,060/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-60M-305W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed CT305M10-02 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What fuse or breaker size does NEC 690.8 require for CertainTeed CT305M10-02?
Multiplying CertainTeed CT305M10-02's 10.06 A short-circuit current by 1.56 equals 15.69 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for CertainTeed CT305M10-02 before finalizing component orders.
Can CertainTeed CT305M10-02 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.82 V cold Voc at 14 F and handles 10.06 A Isc; string inverters cap CertainTeed CT305M10-02 at 13 panels on 600 V.
Is CertainTeed CT305M10-02 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed CT305M10-02 rely on utility bill offset (~$2,060/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)