AXITEC AC-305M/60S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-305M/60S is a 305.0 W STC (278.1 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 18.75% efficiency, 39.81 V Voc at 25 C, and 44.03 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
278.1 W
Voc @ 25C
39.81 V
Efficiency
18.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-305M/60S Compare Against Peer CEC Listings?

Solar engineering breakdown for AXITEC AC-305M/60S: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Across 5,889 Mono-c-Si listings from AXITEC and peers, AXITEC AC-305M/60S stands 105.0 W below the 410.0 W Mono-c-Si median and typical 91.2% PTC-to-STC thermal output (278.1 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,527-$2,518/yr in baseline US bill offset. Lower 39.81 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does AXITEC AC-305M/60S Fall Across Listed CEC Models?

Distribution marker showing AXITEC AC-305M/60S (305.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-305M/60S (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-305M/60S: 305.0 W

What Dataset Percentiles Define AXITEC AC-305M/60S?

Dataset percentiles tracking AXITEC AC-305M/60S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

AXITEC AC-305M/60S Engineering BenchmarksPercentile comparison of AXITEC AC-305M/60S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention91.2%Module Efficiency18.75%

What Do the Dataset Ranks Show for AXITEC AC-305M/60S?

Benchmark highlights for AXITEC AC-305M/60S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,926

18.75% Aperture Efficiency

Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.03 V at -10 C (572.4 V string) and 45.24 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 43.9 m2 (473 sq ft) producing 7,509 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.81 * (1 + (-0.303/100) * (-10 - 25)) = 44.03 V | OCPD = 1.56 * 9.83 = 15.33 A

Inputs from CEC Modules.csv for AXITEC AC-305M/60S: Voc=39.81 V, beta_Voc=-0.303%/C, Isc=9.83 A, STC=305.0 W, Area=1.627 m2.

Result: 13 panels max on 600 V (572.4 V); 27 panels for 8 kW (473 sq ft).

What Are the Published CEC Specifications for AXITEC AC-305M/60S?

Official CEC datasheet figures for AXITEC AC-305M/60S (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-305M/60S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 278.1 W (91.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.81 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.41 V / 9.41 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.303 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.75% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-305M/60S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many AXITEC AC-305M/60S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 350 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 473 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 578 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Consolidated AXITEC wattage variants sharing the AXITEC AC-305M/60S mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the AXITEC AC-305M/60S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-300M/60S 300.0 W 273.5 W 39.72 V 32.37 V 18.44%
AXITEC AC-305M/60S 305.0 W 278.1 W 39.81 V 32.41 V 18.75%
AXITEC AC-310M/60S 310.0 W 282.9 W 39.9 V 32.46 V 19.05%

How Many AXITEC AC-305M/60S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-305M/60S (44.03 V at 14 F).

Computed from Voc=39.81V and beta_Voc=-0.303%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.24 V 13 panels 588.1 V 22 panels
-10 C (14 F) 44.03 V 13 panels 572.4 V 22 panels
0 C (32 F) 42.83 V 14 panels 599.6 V 23 panels
25 C (77 F STC) 39.81 V 15 panels 597.2 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-305M/60S?

Competing CEC solar panels closest to AXITEC AC-305M/60S in nameplate wattage and Voc, starting with DuCal Solar Technology LLC DST305M-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DuCal Solar Technology LLC DST305M-60
DuCal Solar Technology LLC
305.0 W Tie (0 W) 40.0 V 18.75% 90.3%
Enphase Energy Inc XACM-IQ7-LR6-60PB-305M
Enphase Energy Inc
305.0 W Tie (0 W) 40.2 V 19.3% 91.4%
DEHUI SOLAR POWER INC DH-60M-305W
DEHUI SOLAR POWER INC
305.0 W Tie (0 W) 40.3 V 18.94% 91.4%
CertainTeed CT305M10-02
CertainTeed
305.0 W Tie (0 W) 40.79 V 18.75% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-305M/60S?

Evaluate AXITEC AC-305M/60S (305.0 W STC, 39.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-305M/60S reaches 45.24 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 473 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (473 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-305M/60S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-305M/60S 8 kW Residential Fit

Needs 27 modules (473 sq ft) with a 20 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DuCal Solar Technology LLC DST305M-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 278.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-305M/60S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for AXITEC AC-305M/60S?

Multiplying AXITEC AC-305M/60S's 9.83 A short-circuit current by 1.56 equals 15.33 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can AXITEC AC-305M/60S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.03 V cold Voc at 14 F and handles 9.83 A Isc; string inverters cap AXITEC AC-305M/60S at 13 panels on 600 V.

Is AXITEC AC-305M/60S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-305M/60S rely on utility bill offset (~$2,060/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.