Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SC 2660 UP-US 600V 2566A {600V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SC 2660 UP-US 600V 2566A {600V} outputs 2,616,157 W AC at 600 V, 3-phase (2517.5 A continuous, 3,150 A OCPD), ranking #1,520 of 2,343 CEC inverters at 96.52% efficiency with a 880-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,616,157 W
AC Voltage
600 V, 3-phase
Min PV Breaker
3,150 A (parallel Cu feeders)
CEC Efficiency
96.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SC 2660 UP-US 600V 2566A {600V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for SMA America: SC 2660 UP-US 600V 2566A {600V}.

Ranking #70 of 2,343 CEC inverters (top 3.0%; higher than 97.0% of peers), SMA America: SC 2660 UP-US 600V 2566A {600V} is a hybrid battery-capable inverter delivering 2,616,157 W continuous AC at 600 V, 3-phase (2517.5 A continuous). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 96.52% (-1.76 pts vs the 98.28% 600 V median) against peers like INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (2,582,000 W).

Where Does SMA America: SC 2660 UP-US 600V 2566A {600V} Fall Across Listed CEC Models?

Marks SMA America: SC 2660 UP-US 600V 2566A {600V} (2,616,157 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SC 2660 UP-US 600V 2566A {600V} (2,616,157 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SC 26: 2,616,157 W

What Dataset Percentiles Define SMA America: SC 2660 UP-US 600V 2566A {600V}?

Benchmarks SMA America: SC 2660 UP-US 600V 2566A {600V} continuous AC output, 96.52% CEC weighted efficiency, and 3,150 A OCPD breaker demand.

SMA America: SC 2660 UP-US 600V 2566A {600V} Technical ThresholdsPercentile comparison for SMA America: SC 2660 UP-US 600V 2566A {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,616,157 WCEC Efficiency96.52%Backfeed Breaker3,150 A

What Do the Dataset Ranks Show for SMA America: SC 2660 UP-US 600V 2566A {600V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SC 2660 UP-US 600V 2566A {600V} by SMA America.

Eff #1,520 / 2,343

96.52% CEC Weighted Efficiency

-1.76 pts vs the 98.28% 600 V median; overall power rank #70 (2,616,157 W, top 3.0%; higher than 97.0% of peers).

NEC 705.12 Check

3,150 A Required Backfeed OCPD

125% x 2517.5 A = 3146.9 A -> 3,150 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

880 V - 1,200 V (Max 1,200 V DC)

Tracking span of 320.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2616157.0W / 600 V 3-phase -> 2517.5 A | Breaker >= 1.25 * 2517.5 = 3146.9 A -> 3,150 A

CEC Inverters.csv for SMA America: SC 2660 UP-US 600V 2566A {600V}: Paco=2616157.0 W, Vac=600 V, Vdcmax=1200.0 V, Eff=96.52%.

Result: Min 3,150 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for SMA America: SC 2660 UP-US 600V 2566A {600V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SC 2660 UP-US 600V 2566A {600V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SC 2660 UP-US 600V 2566A {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,616,157 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 880 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 2794.29 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.52% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SC 2660 UP-US 600V 2566A {600V} (600 V, 3-phase)?

Evaluates SMA America: SC 2660 UP-US 600V 2566A {600V} (3,150 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SC 2660 UP-US 600V 2566A {600V} (3150 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 3,150 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 3,150 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 3,150 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 3,150 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 3,150 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With SMA America: SC 2660 UP-US 600V 2566A {600V}?

Sample PV string lengths aligned within 880-1,200 V MPPT and 1,200 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 880.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 21 panels (fixed) 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 27 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 26 panels (fixed) 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 22 panels (fixed) 11.33 kW

Which Competing Grid-Support Inverters Compare to SMA America: SC 2660 UP-US 600V 2566A {600V}?

Competing CEC grid-support inverters near 2,616,157 W AC and 600 V, 3-phase, led by INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}
INGETEAM POWER TECHNOLOGY SA
2,582,000 W -34157 W 600.0 V 1500.0 V 97.65%
Power Electronics: FS2600CU15O3 {600V}
Power Electronics
2,770,200 W +154043 W 600.0 V 1200.0 V 97.85%
Power Electronics: FS2250CU15O3 {600V}
Power Electronics
2,420,370 W -195787 W 600.0 V 1200.0 V 97.82%
Power Electronics: FS2225CU15 {600V}
Power Electronics
2,417,080 W -199077 W 600.0 V 1200.0 V 97.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SC 2660 UP-US 600V 2566A {600V}?

Check SMA America: SC 2660 UP-US 600V 2566A {600V} (2,616,157 W AC, 3,150 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SC 2660 UP-US 600V 2566A {600V}.

SMA America: SC 2660 UP-US 600V 2566A {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,150 A OCPD breaker (2517.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.52%) and MPPT window (880-1,200 V) directly against INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (2,582,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SC 2660 UP-US 600V 2566A {600V} by SMA America covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does SMA America: SC 2660 UP-US 600V 2566A {600V} require?

At 2,616,157 W continuous AC (600 V, 3-phase), continuous current is 2517.5 A; 125% NEC 690.8/705.12 sizing requires a 3,150 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SC 2660 UP-US 600V 2566A {600V} require?

At 2,616,157 W AC and 600 V, 3-phase, continuous line current is 2517.5 A, requiring a 3,150 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does SMA America: SC 2660 UP-US 600V 2566A {600V} compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?

SMA America: SC 2660 UP-US 600V 2566A {600V} delivers 2,616,157 W AC at 96.52% CEC efficiency with a 1,200 V DC ceiling, while INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} outputs 2,582,000 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.