Power Electronics: FS2600CU15O3 {600V} outputs 2,770,200 W AC at 600 V, 3-phase (2665.7 A continuous, 3,350 A OCPD), ranking #411 of 2,343 CEC inverters at 97.85% efficiency with a 849-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 2,770,200 W
- AC Voltage
- 600 V, 3-phase
- Min PV Breaker
- 3,350 A (parallel Cu feeders)
- CEC Efficiency
- 97.85%
How Does Power Electronics: FS2600CU15O3 {600V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for Power Electronics: FS2600CU15O3 {600V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Rated at 2,770,200 W AC (2665.7 A continuous), Power Electronics: FS2600CU15O3 {600V} ranks #411 of 2,343 CEC units at 97.85% efficiency (-0.43 pts vs the 98.28% 600 V median). Minimum 75 C copper conductor sizing for its 3,350 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,200 V DC at record local winter lows.
Where Does Power Electronics: FS2600CU15O3 {600V} Fall Across Listed CEC Models?
Marks Power Electronics: FS2600CU15O3 {600V} (2,770,200 W AC) across the California Energy Commission inverter AC capacity distribution. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Power Electronics: FS2600CU15O3 {600V}?
Benchmarks Power Electronics: FS2600CU15O3 {600V} continuous AC output, 97.85% CEC weighted efficiency, and 3,350 A OCPD breaker demand.
What Do the Dataset Ranks Show for Power Electronics: FS2600CU15O3 {600V}?
Four key NEC 705.12 and California Energy Commission metrics defining Power Electronics: FS2600CU15O3 {600V} by Power Electronics. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
97.85% CEC Weighted Efficiency
-0.43 pts vs the 98.28% 600 V median; overall power rank #64 (2,770,200 W, top 2.7%; higher than 97.3% of peers).
3,350 A Required Backfeed OCPD
125% x 2665.7 A = 3332.1 A -> 3,350 A standard OCPD using parallel Cu feeders (75 C).
849 V - 1,200 V (Max 1,200 V DC)
Tracking span of 351.0 V; listed since 2018-10-15 (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 2770200.0W / 600 V 3-phase -> 2665.7 A | Breaker >= 1.25 * 2665.7 = 3332.1 A -> 3,350 A
CEC Inverters.csv for Power Electronics: FS2600CU15O3 {600V}: Paco=2770200.0 W, Vac=600 V, Vdcmax=1200.0 V, Eff=97.85%.
Result: Min 3,350 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for Power Electronics: FS2600CU15O3 {600V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Power Electronics: FS2600CU15O3 {600V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 2,770,200 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 600 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 849 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 3011.67 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.85% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Power Electronics: FS2600CU15O3 {600V} (600 V, 3-phase)?
Evaluates Power Electronics: FS2600CU15O3 {600V} (3,350 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (600V) | 40 A | 3,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (600V) | 80 A | 3,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (600V) | 120 A | 3,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (600V) | 160 A | 3,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (600V) | 240 A | 3,350 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With Power Electronics: FS2600CU15O3 {600V}?
Sample PV string lengths aligned within 849-1,200 V MPPT and 1,200 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 20 to 21 panels | 12.39 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 26 to 28 panels | 12.32 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 25 to 26 panels | 11.05 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 21 to 22 panels | 11.33 kW |
Which Competing Grid-Support Inverters Compare to Power Electronics: FS2600CU15O3 {600V}?
Competing CEC grid-support inverters near 2,770,200 W AC and 600 V, 3-phase, led by SMA America: SC 2660 UP-US 600V 2566A {600V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| SMA America: SC 2660 UP-US 600V 2566A {600V} SMA America |
2,616,157 W | -154043 W | 600.0 V | 1200.0 V | 96.52% |
| SMA America: SC 2750-EV-US {600V} SMA America |
2,600,000 W | -170200 W | 600.0 V | 1200.0 V | 97.12% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} INGETEAM POWER TECHNOLOGY SA |
2,582,000 W | -188200 W | 600.0 V | 1500.0 V | 97.65% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} INGETEAM POWER TECHNOLOGY SA |
3,095,300 W | +325100 W | 600.0 V | 1300.0 V | 97.54% |
What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS2600CU15O3 {600V}?
Check Power Electronics: FS2600CU15O3 {600V} (2,770,200 W AC, 3,350 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS2600CU15O3 {600V}.
Power Electronics: FS2600CU15O3 {600V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 3,350 A OCPD breaker (2665.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.85%) and MPPT window (849-1,200 V) directly against SMA America: SC 2660 UP-US 600V 2566A {600V} (2,616,157 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Power Electronics: FS2600CU15O3 {600V} by Power Electronics covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.
What breaker and wire size does Power Electronics: FS2600CU15O3 {600V} require?
At 2,770,200 W continuous AC (600 V, 3-phase), continuous current is 2665.7 A; 125% NEC 690.8/705.12 sizing requires a 3,350 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does Power Electronics: FS2600CU15O3 {600V} require?
At 2,770,200 W AC and 600 V, 3-phase, continuous line current is 2665.7 A, requiring a 3,350 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.
How does Power Electronics: FS2600CU15O3 {600V} compare to SMA America: SC 2660 UP-US 600V 2566A {600V}?
Power Electronics: FS2600CU15O3 {600V} delivers 2,770,200 W AC at 97.85% CEC efficiency with a 1,200 V DC ceiling, while SMA America: SC 2660 UP-US 600V 2566A {600V} outputs 2,616,157 W at 600 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)