INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} outputs 3,095,300 W AC at 600 V, 3-phase (2978.5 A continuous, 3,750 A OCPD), ranking #532 of 2,343 CEC inverters at 97.54% efficiency with a 857-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,095,300 W
- AC Voltage
- 600 V, 3-phase
- Min PV Breaker
- 3,750 A (parallel Cu feeders)
- CEC Efficiency
- 97.54%
How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} Compare Against Peer CEC Listings?
How INGETEAM POWER TECHNOLOGY SA INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} compares on 97.54% efficiency, MPPT span, and 120% busbar interconnection.
INGETEAM POWER TECHNOLOGY SA certifies INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} (grid-tied PV inverter, active in CEC directory) at 3,095,300 W AC (2,845,971 W above the 249,329 W 600 V median). Its 1,300 V DC ceiling pairs with an MPPT window of 857-1,300 V (span 443.0 V). Under NEC 690.8/705.12, 125% sizing demands parallel Cu feeders conductors on a 3,750 A OCPD.
Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} Fall Across Listed CEC Models?
Position of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} (3,095,300 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?
Percentile placement of INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}.
97.54% CEC Weighted Efficiency
-0.74 pts vs the 98.28% 600 V median; overall power rank #52 (3,095,300 W, top 2.3%; higher than 97.7% of peers).
3,750 A Required Backfeed OCPD
125% x 2978.5 A = 3723.1 A -> 3,750 A standard OCPD using parallel Cu feeders (75 C).
857 V - 1,300 V (Max 1,300 V DC)
Tracking span of 443.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3095300.0W / 600 V 3-phase -> 2978.5 A | Breaker >= 1.25 * 2978.5 = 3723.1 A -> 3,750 A
CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}: Paco=3095300.0 W, Vac=600 V, Vdcmax=1300.0 V, Eff=97.54%.
Result: Min 3,750 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,095,300 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 600 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,300 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 857 V - 1,300 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 2712.27 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.54% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} (600 V, 3-phase)?
Check whether INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} (3,750 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (600V) | 40 A | 3,750 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (600V) | 80 A | 3,750 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (600V) | 120 A | 3,750 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (600V) | 160 A | 3,750 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (600V) | 240 A | 3,750 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?
Verified cold-weather (-10 C) series module counts matched to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}'s 1,300 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 20 to 23 panels | 13.57 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 26 to 30 panels | 13.2 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 25 to 29 panels | 12.32 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 30 to 32 panels | 6.4 kW |
Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?
Alternative CEC inverters comparable to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}, including Power Electronics: FP3000K3 {600V} (3,116,969 W) at 600 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Power Electronics: FP3000K3 {600V} Power Electronics |
3,116,969 W | +21669 W | 600.0 V | 1200.0 V | 97.99% |
| Power Electronics: FS3000K {600V} Power Electronics |
3,121,310 W | +26010 W | 600.0 V | 1200.0 V | 97.89% |
| POWER ELECTRONICS: FS2865K {600V} POWER ELECTRONICS |
2,858,630 W | -236670 W | 600.0 V | 1200.0 V | 97.93% |
| Power Electronics: FS2600CU15 {600V} Power Electronics |
2,821,840 W | -273460 W | 600.0 V | 1200.0 V | 97.75% |
What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?
Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} (3,095,300 W AC, 3,750 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}.
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 3,750 A OCPD breaker (2978.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.54%) and MPPT window (857-1,300 V) directly against Power Electronics: FP3000K3 {600V} (3,116,969 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.
What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} require?
At 3,095,300 W continuous AC (600 V, 3-phase), continuous current is 2978.5 A; 125% NEC 690.8/705.12 sizing requires a 3,750 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} require?
At 3,095,300 W AC and 600 V, 3-phase, continuous line current is 2978.5 A, requiring a 3,750 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.
How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} compare to Power Electronics: FP3000K3 {600V}?
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} delivers 3,095,300 W AC at 97.54% CEC efficiency with a 1,300 V DC ceiling, while Power Electronics: FP3000K3 {600V} outputs 3,116,969 W at 600 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)